Literature DB >> 18383692

Accurate dosimetry with GafChromic EBT film of a 6 MV photon beam in water: what level is achievable?

L J van Battum1, D Hoffmans, H Piersma, S Heukelom.   

Abstract

This paper focuses on the accuracy, in absolute dose measurements, with GafChromicTM EBT film achievable in water for a 6 MV photon beam up to a dose of 2.3 Gy. Motivation is to get an absolute dose detection system to measure up dose distributions in a (water) phantom, to check dose calculations. An Epson 1680 color (red green blue) transmission flatbed scanner has been used as film scanning system, where the response in the red color channel has been extracted and used for the analyses. The influence of the flatbed film scanner on the film based dose detection process was investigated. The scan procedure has been optimized; i.e. for instance a lateral correction curve was derived to correct the scan value, up to 10%, as a function of optical density and lateral position. Sensitometric curves of different film batches were evaluated in portrait and landscape scan mode. Between various batches important variations in sensitometric curve were observed. Energy dependence of the film is negligible, while a slight variation in dose response is observed for very large angles between film surface and incident photon beam. Improved accuracy in absolute dose detection can be obtained by repetition of a film measurement to tackle at least the inherent presence of film inhomogeneous construction. We state that the overall uncertainty is random in absolute EBT film dose detection and of the order of 1.3% (1 SD) under the condition that the film is scanned in a limited centered area on the scanner and at least two films have been applied. At last we advise to check a new film batch on its characteristics compared to available information, before using that batch for absolute dose measurements.

Entities:  

Mesh:

Substances:

Year:  2008        PMID: 18383692     DOI: 10.1118/1.2828196

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  38 in total

1.  Toward a better understanding of the gamma index: Investigation of parameters with a surface-based distance method.

Authors:  Heng Li; Lei Dong; Lifei Zhang; James N Yang; Michael T Gillin; X Ronald Zhu
Journal:  Med Phys       Date:  2011-12       Impact factor: 4.071

2.  Surface dose and build-up region measurements with wedge filters for 6 and 18 MV photon beams.

Authors:  Hatice Bilge; Nurdan Ozbek; Murat Okutan; Aydin Cakir; Hilal Acar
Journal:  Jpn J Radiol       Date:  2010-02-26       Impact factor: 2.374

3.  Evaluation of the absorbed dose to the breast using radiochromic film in a dedicated CT mammotomography system employing a quasi-monochromatic x-ray beam.

Authors:  Dominic J Crotty; Samuel L Brady; D'Vone C Jackson; Greta I Toncheva; Colin E Anderson; Terry T Yoshizumi; Martin P Tornai
Journal:  Med Phys       Date:  2011-06       Impact factor: 4.071

4.  Correcting lateral response artifacts from flatbed scanners for radiochromic film dosimetry.

Authors:  David Lewis; Maria F Chan
Journal:  Med Phys       Date:  2015-01       Impact factor: 4.071

5.  Dose calculation accuracies in whole breast radiotherapy treatment planning: a multi-institutional study.

Authors:  Shogo Hatanaka; Yuki Miyabe; Naoki Tohyama; Yu Kumazaki; Masahiko Kurooka; Hiroyuki Okamoto; Hidenobu Tachibana; Satoshi Kito; Akihisa Wakita; Yuko Ohotomo; Hiroyuki Ikagawa; Satoshi Ishikura; Miwako Nozaki; Yoshikazu Kagami; Masahiro Hiraoka; Teiji Nishio
Journal:  Radiol Phys Technol       Date:  2015-02-03

6.  Monte Carlo Modeling of the Agility MLC for IMRT and VMAT Calculations.

Authors:  Shingo Ohira; Hideki Takegawa; Masayoshi Miyazaki; Masahiko Koizumi; Teruki Teshima
Journal:  In Vivo       Date:  2020 Sep-Oct       Impact factor: 2.155

7.  Characterization of a 137Cs irradiator from a new perspective with modern dosimetric tools.

Authors:  Samuel L Brady; Greta Toncheva; Mark W Dewhirst; Terry T Yoshizumi
Journal:  Health Phys       Date:  2009-09       Impact factor: 1.316

8.  A feasibility study using radiochromic films for fast neutron 2D passive dosimetry.

Authors:  Samuel L Brady; Rathnayaka Gunasingha; Terry T Yoshizumi; Calvin R Howell; Alexander S Crowell; Brent Fallin; Anton P Tonchev; Mark W Dewhirst
Journal:  Phys Med Biol       Date:  2010-08-06       Impact factor: 3.609

9.  Monte Carlo simulations and radiation dosimetry measurements of peripherally applied HDR 192Ir breast brachytherapy D-shaped applicators.

Authors:  Yun Yang; Mark J Rivard
Journal:  Med Phys       Date:  2009-03       Impact factor: 4.071

10.  Technical Note: On GAFChromic EBT-XD film and the lateral response artifact.

Authors:  David F Lewis; Maria F Chan
Journal:  Med Phys       Date:  2016-02       Impact factor: 4.071

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.