Literature DB >> 17278496

Absorption spectroscopy of EBT model GAFCHROMIC film.

Slobodan Devic1, Nada Tomic, Zhiyu Pang, Jan Seuntjens, Ervin B Podgorsak, Christopher G Soares.   

Abstract

The introduction of radiochromic films has solved some of the problems associated with conventional 2D radiation detectors. Their high spatial resolution, low energy dependence, and near-tissue equivalence make them ideal for measurement of dose distributions in radiation fields with high dose gradients. Precise knowledge of the absorption spectra of these detectors can help to develop more suitable optical densitometers and potentially extend the use of these films to other areas such as the measurement of the radiation beam spectral information. The goal of this study is to present results of absorption spectra measurements for the new GAFCHROMIC film, EBT type, exposed to 6 MV photon beam in the dose range from 0 to 6 Gy. Spectroscopic analysis reveals that in addition to the two main absorption peaks, centered at around 583 and 635 nm, the absorption spectrum in the spectral range from 350 to 800 nm contains six more absorption bands. Comparison of the absorption spectra reveals that previous HD-810, MD-55, as well as HS GAFCHROMIC film models, have nearly the same sensitive layer base material, whereas the new EBT model, GAFCHROMIC film has a different composition of its sensitive layer. We have found that the two most prominent absorption bands in EBT model radiochromic film do not change their central wavelength position with change in a dose deposited to the film samples.

Entities:  

Mesh:

Year:  2007        PMID: 17278496     DOI: 10.1118/1.2400615

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  14 in total

1.  Implementation of radiochromic film dosimetry protocol for volumetric dose assessments to various organs during diagnostic CT procedures.

Authors:  Samuel Brady; Terry Yoshizumi; Greta Toncheva; Donald Frus
Journal:  Med Phys       Date:  2010-09       Impact factor: 4.071

2.  Simulation for improvement of system sensitivity of radiochromic film dosimetry with different band-pass filters and scanner light intensities.

Authors:  Takeshi Kamomae; Yuki Miyabe; Akira Sawada; Osamu Matoba; Manabu Nakata; Shinsuke Yano; Toru Takakura; Takashi Mizowaki; Akio Itoh; Masahiro Hiraoka
Journal:  Radiol Phys Technol       Date:  2011-03-17

3.  Evaluation of the absorbed dose to the breast using radiochromic film in a dedicated CT mammotomography system employing a quasi-monochromatic x-ray beam.

Authors:  Dominic J Crotty; Samuel L Brady; D'Vone C Jackson; Greta I Toncheva; Colin E Anderson; Terry T Yoshizumi; Martin P Tornai
Journal:  Med Phys       Date:  2011-06       Impact factor: 4.071

4.  Investigation into the feasibility of using PRESAGE/optical-CT dosimetry for the verification of gating treatments.

Authors:  Samuel L Brady; William E Brown; Corey G Clift; Sua Yoo; Mark Oldham
Journal:  Phys Med Biol       Date:  2010-03-26       Impact factor: 3.609

5.  Isodose curve mappings measured while undergoing rotation for quality assurance testing of a 137Cs irradiator.

Authors:  Samuel L Brady; Terry T Yoshizumi; Colin Anderson-Evans; Giao Nguyen
Journal:  Health Phys       Date:  2012-02       Impact factor: 1.316

6.  Tumour bed irradiation of human tumour xenografts in a nude rat model using a common X-ray tube.

Authors:  S V Tokalov; W Enghardt; N Abolmaali
Journal:  J Biosci       Date:  2010-06       Impact factor: 1.826

7.  Characterization of a 137Cs irradiator from a new perspective with modern dosimetric tools.

Authors:  Samuel L Brady; Greta Toncheva; Mark W Dewhirst; Terry T Yoshizumi
Journal:  Health Phys       Date:  2009-09       Impact factor: 1.316

8.  A feasibility study using radiochromic films for fast neutron 2D passive dosimetry.

Authors:  Samuel L Brady; Rathnayaka Gunasingha; Terry T Yoshizumi; Calvin R Howell; Alexander S Crowell; Brent Fallin; Anton P Tonchev; Mark W Dewhirst
Journal:  Phys Med Biol       Date:  2010-08-06       Impact factor: 3.609

9.  Clinical commissioning and use of the Novalis Tx linear accelerator for SRS and SBRT.

Authors:  Jinkoo Kim; Ning Wen; Jian-Yue Jin; Nicole Walls; Sangroh Kim; Haisen Li; Lei Ren; Yimei Huang; Anthony Doemer; Kathleen Faber; Tina Kunkel; Ahssan Balawi; Kimberly Garbarino; Kenneth Levin; Samir Patel; Munther Ajlouni; Brett Miller; Teamor Nurushev; Calvin Huntzinger; Raymond Schulz; Indrin J Chetty; Benjamin Movsas; Samuel Ryu
Journal:  J Appl Clin Med Phys       Date:  2012-05-10       Impact factor: 2.102

10.  Characterization of the effect of MRI on Gafchromic film dosimetry.

Authors:  Meral L Reyhan; Ting Chen; Miao Zhang
Journal:  J Appl Clin Med Phys       Date:  2015-11-08       Impact factor: 2.102

View more