Literature DB >> 17905246

Reduction of flow- and eddy-currents-induced image artifacts in coronary magnetic resonance angiography using a linear centric-encoding SSFP sequence.

Xiaoming Bi1, Jaeseok Park, Vibhas Deshpande, Orlando Simonetti, Gerhard Laub, Debiao Li.   

Abstract

Coronary magnetic resonance angiography (MRA) acquired using steady-state free precession (SSFP) sequences tends to suffer from image artifacts caused by local magnetic field inhomogeneities. Flow- and gradient-switching-induced eddy currents are important sources of such phase errors, especially under off-resonant conditions. In this study, we propose to reduce these image artifacts by using a linear centric-encoding (LCE) scheme in the phase-encoding (PE) direction. Abrupt change in gradients, including magnitude and polarity between consecutive radiofrequency cycles, is minimized using the LCE scheme. Results from numeric simulations and phantom studies demonstrated that signal oscillation can be markedly reduced using LCE as compared to conventional alternating centric-encoding (ACE) scheme. The image quality of coronary arteries was improved at both 1.5 and 3.0 T using LCE compared to those acquired using ACE PE scheme (1.5 T: ACE/LCE=2.2+/-0.8/3.0+/-0.6, P=.02; 3.0 T: ACE/LCE=2.1+/-1.1/3.0+/-0.8, P=.01). In conclusion, flow- and eddy-currents-induced imaging artifacts in coronary MRA using SSFP sequence can be markedly reduced with LCE acquisition of PE lines.

Entities:  

Mesh:

Year:  2007        PMID: 17905246      PMCID: PMC2084053          DOI: 10.1016/j.mri.2007.01.004

Source DB:  PubMed          Journal:  Magn Reson Imaging        ISSN: 0730-725X            Impact factor:   2.546


  28 in total

1.  SENSE: sensitivity encoding for fast MRI.

Authors:  K P Pruessmann; M Weiger; M B Scheidegger; P Boesiger
Journal:  Magn Reson Med       Date:  1999-11       Impact factor: 4.668

2.  3D magnetization-prepared true-FISP: a new technique for imaging coronary arteries.

Authors:  V S Deshpande; S M Shea; G Laub; O P Simonetti; J P Finn; D Li
Journal:  Magn Reson Med       Date:  2001-09       Impact factor: 4.668

3.  Magnetization preparation during the steady state: fat-saturated 3D TrueFISP.

Authors:  K Scheffler; O Heid; J Hennig
Journal:  Magn Reson Med       Date:  2001-06       Impact factor: 4.668

4.  Single-breathhold 3D-trueFISP cine cardiac imaging.

Authors:  Bernd A Jung; Jürgen Hennig; Klaus Scheffler
Journal:  Magn Reson Med       Date:  2002-11       Impact factor: 4.668

5.  Generalized autocalibrating partially parallel acquisitions (GRAPPA).

Authors:  Mark A Griswold; Peter M Jakob; Robin M Heidemann; Mathias Nittka; Vladimir Jellus; Jianmin Wang; Berthold Kiefer; Axel Haase
Journal:  Magn Reson Med       Date:  2002-06       Impact factor: 4.668

6.  Reduction of transient signal oscillations in true-FISP using a linear flip angle series magnetization preparation.

Authors:  Vibhas S Deshpande; Yiu-Cho Chung; Qiang Zhang; Steven M Shea; Debiao Li
Journal:  Magn Reson Med       Date:  2003-01       Impact factor: 4.668

7.  Frequency-modulated steady-state free precession imaging.

Authors:  D L Foxall
Journal:  Magn Reson Med       Date:  2002-09       Impact factor: 4.668

8.  Double average parallel steady-state free precession imaging: optimized eddy current and transient oscillation compensation.

Authors:  M Markl; J Leupold; O Bieri; K Scheffler; J Hennig
Journal:  Magn Reson Med       Date:  2005-10       Impact factor: 4.668

9.  Coronary magnetic resonance angiography for the detection of coronary stenoses.

Authors:  W Y Kim; P G Danias; M Stuber; S D Flamm; S Plein; E Nagel; S E Langerak; O M Weber; E M Pedersen; M Schmidt; R M Botnar; W J Manning
Journal:  N Engl J Med       Date:  2001-12-27       Impact factor: 91.245

10.  Preliminary report on in vivo coronary MRA at 3 Tesla in humans.

Authors:  Matthias Stuber; René M Botnar; Stefan E Fischer; Rolf Lamerichs; Jouke Smink; Paul Harvey; Warren J Manning
Journal:  Magn Reson Med       Date:  2002-09       Impact factor: 4.668

View more
  6 in total

1.  Simultaneous multi-slice Turbo-FLASH imaging with CAIPIRINHA for whole brain distortion-free pseudo-continuous arterial spin labeling at 3 and 7 T.

Authors:  Yi Wang; Steen Moeller; Xiufeng Li; An T Vu; Kate Krasileva; Kamil Ugurbil; Essa Yacoub; Danny J J Wang
Journal:  Neuroimage       Date:  2015-03-30       Impact factor: 6.556

2.  3D noncontrast MR angiography of the distal lower extremities using flow-sensitive dephasing (FSD)-prepared balanced SSFP.

Authors:  Zhaoyang Fan; John Sheehan; Xiaoming Bi; Xin Liu; James Carr; Debiao Li
Journal:  Magn Reson Med       Date:  2009-12       Impact factor: 4.668

3.  Whole heart coronary imaging with flexible acquisition window and trigger delay.

Authors:  Keigo Kawaji; Murilo Foppa; Sébastien Roujol; Mehmet Akçakaya; Reza Nezafat
Journal:  PLoS One       Date:  2015-02-26       Impact factor: 3.240

4.  Pseudo-projection-driven, self-gated cardiac cine imaging using cartesian golden step phase encoding.

Authors:  Liheng Guo; J Andrew Derbyshire; Daniel A Herzka
Journal:  Magn Reson Med       Date:  2015-10-31       Impact factor: 4.668

5.  Sorted Golden-step phase encoding: an improved Golden-step imaging technique for cardiac and respiratory self-gated cine cardiovascular magnetic resonance imaging.

Authors:  Liheng Guo; Daniel A Herzka
Journal:  J Cardiovasc Magn Reson       Date:  2019-04-18       Impact factor: 5.364

6.  Prospective GIRF-based RF phase cycling to reduce eddy current-induced steady-state disruption in bSSFP imaging.

Authors:  Tom Bruijnen; Bjorn Stemkens; Cornelis Antonius Theodorus van den Berg; Rob Hendrikus Nicolaas Tijssen
Journal:  Magn Reson Med       Date:  2019-11-22       Impact factor: 4.668

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.