Literature DB >> 20667807

Hybrid cone-beam tomographic reconstruction: incorporation of prior anatomical models to compensate for missing data.

Ofri Sadowsky1, Junghoon Lee, E Grant Sutter, Simon J Wall, Jerry L Prince, Russell H Taylor.   

Abstract

We propose a method for improving the quality of cone-beam tomographic reconstruction done with a C-arm. C-arm scans frequently suffer from incomplete information due to image truncation, limited scan length, or other limitations. Our proposed "hybrid reconstruction" method injects information from a prior anatomical model, derived from a subject-specific computed tomography (CT) or from a statistical database (atlas), where the C-arm X-ray data is missing. This significantly reduces reconstruction artifacts with little loss of true information from the X-ray projections. The methods consist of constructing anatomical models, fast rendering of digitally reconstructed radiograph (DRR) projections of the models, rigid or deformable registration of the model and the X-ray images, and fusion of the DRR and X-ray projections, all prior to a conventional filtered back-projection algorithm. Our experiments, conducted with a mobile image intensifier C-arm, demonstrate visually and quantitatively the contribution of data fusion to image quality, which we assess through comparison to a "ground truth" CT. Importantly, we show that a significantly improved reconstruction can be obtained from a C-arm scan as short as 90° by complementing the observed projections with DRRs of two prior models, namely an atlas and a preoperative same-patient CT. The hybrid reconstruction principles are applicable to other types of C-arms as well.

Entities:  

Mesh:

Year:  2010        PMID: 20667807      PMCID: PMC3415332          DOI: 10.1109/TMI.2010.2060491

Source DB:  PubMed          Journal:  IEEE Trans Med Imaging        ISSN: 0278-0062            Impact factor:   10.048


  21 in total

1.  Feldkamp-type VOI reconstruction from super-short-scan cone-beam data.

Authors:  Hengyong Yu; Ge Wang
Journal:  Med Phys       Date:  2004-06       Impact factor: 4.071

2.  Image quality assessment: from error visibility to structural similarity.

Authors:  Zhou Wang; Alan Conrad Bovik; Hamid Rahim Sheikh; Eero P Simoncelli
Journal:  IEEE Trans Image Process       Date:  2004-04       Impact factor: 10.856

3.  Image reconstruction in regions-of-interest from truncated projections in a reduced fan-beam scan.

Authors:  Yu Zou; Xiaochuan Pan; Emil Y Sidky
Journal:  Phys Med Biol       Date:  2005-01-07       Impact factor: 3.609

4.  Normalized mutual information based registration using k-means clustering and shading correction.

Authors:  Z F Knops; J B A Maintz; M A Viergever; J P W Pluim
Journal:  Med Image Anal       Date:  2005-08-18       Impact factor: 8.545

5.  Tiny a priori knowledge solves the interior problem in computed tomography.

Authors:  Hiroyuki Kudo; Matias Courdurier; Frédéric Noo; Michel Defrise
Journal:  Phys Med Biol       Date:  2008-04-09       Impact factor: 3.609

6.  Geometric calibration of a mobile C-arm for intraoperative cone-beam CT.

Authors:  M J Daly; J H Siewerdsen; Y B Cho; D A Jaffray; J C Irish
Journal:  Med Phys       Date:  2008-05       Impact factor: 4.071

7.  Multi-modal volume registration by maximization of mutual information.

Authors:  W M Wells; P Viola; H Atsumi; S Nakajima; R Kikinis
Journal:  Med Image Anal       Date:  1996-03       Impact factor: 8.545

8.  Three-dimensional computed tomographic reconstruction using a C-arm mounted XRII: correction of image intensifier distortion.

Authors:  R Fahrig; M Moreau; D W Holdsworth
Journal:  Med Phys       Date:  1997-07       Impact factor: 4.071

9.  Multimodality image registration by maximization of mutual information.

Authors:  F Maes; A Collignon; D Vandermeulen; G Marchal; P Suetens
Journal:  IEEE Trans Med Imaging       Date:  1997-04       Impact factor: 10.048

10.  Processing of incomplete measurement data in computed tomography.

Authors:  R M Lewitt
Journal:  Med Phys       Date:  1979 Sep-Oct       Impact factor: 4.071

View more
  8 in total

1.  Deformable registration of CT and cone-beam CT with local intensity matching.

Authors:  Seyoun Park; William Plishker; Harry Quon; John Wong; Raj Shekhar; Junghoon Lee
Journal:  Phys Med Biol       Date:  2017-01-11       Impact factor: 3.609

2.  Volume-of-change cone-beam CT for image-guided surgery.

Authors:  Junghoon Lee; J Webster Stayman; Yoshito Otake; Sebastian Schafer; Wojciech Zbijewski; A Jay Khanna; Jerry L Prince; Jeffrey H Siewerdsen
Journal:  Phys Med Biol       Date:  2012-07-17       Impact factor: 3.609

3.  3D-2D registration for surgical guidance: effect of projection view angles on registration accuracy.

Authors:  A Uneri; Y Otake; A S Wang; G Kleinszig; S Vogt; A J Khanna; J H Siewerdsen
Journal:  Phys Med Biol       Date:  2013-12-19       Impact factor: 3.609

4.  Intraoperative image-based multiview 2D/3D registration for image-guided orthopaedic surgery: incorporation of fiducial-based C-arm tracking and GPU-acceleration.

Authors:  Yoshito Otake; Mehran Armand; Robert S Armiger; Michael D Kutzer; Ehsan Basafa; Peter Kazanzides; Russell H Taylor
Journal:  IEEE Trans Med Imaging       Date:  2011-11-18       Impact factor: 10.048

5.  A method of 2D/3D registration of a statistical mouse atlas with a planar X-ray projection and an optical photo.

Authors:  Hongkai Wang; David B Stout; Arion F Chatziioannou
Journal:  Med Image Anal       Date:  2013-03-05       Impact factor: 8.545

6.  An active contour method for bone cement reconstruction from C-arm x-ray images.

Authors:  Blake C Lucas; Yoshito Otake; Mehran Armand; Russell H Taylor
Journal:  IEEE Trans Med Imaging       Date:  2011-10-13       Impact factor: 10.048

7.  Accurate and robust registration method for computer-assisted high tibial osteotomy surgery.

Authors:  Chuanba Liu; Yimin Song; Xinlong Ma; Tao Sun
Journal:  Int J Comput Assist Radiol Surg       Date:  2022-08-02       Impact factor: 3.421

8.  Probabilistic evaluation of three-dimensional reconstructions from X-ray images spanning a limited angle.

Authors:  Anja Frost; Eike Renners; Michael Hötter; Jörn Ostermann
Journal:  Sensors (Basel)       Date:  2012-12-21       Impact factor: 3.576

  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.