Literature DB >> 9243472

Three-dimensional computed tomographic reconstruction using a C-arm mounted XRII: correction of image intensifier distortion.

R Fahrig1, M Moreau, D W Holdsworth.   

Abstract

X-ray image intensifiers (XRIIs) have many applications in diagnostic imaging including acquisition of near-real-time projection images of the intracranial and coronary vasculature. Recently, there has been some interest in using this projection data to generate three-dimensional (3-D) computed tomographic (CT) reconstructions. The XRII and x-ray tube are rotated around the object, acquiring sufficient data for the simultaneous reconstruction of many transverse slices. Three-dimensional reconstructions are compromised, however, if the projection data is geometrically distorted in any way. Previous studies have shown the distortion in XRIIs to be substantial and to be highly angular dependent. In this paper, we present a global correction technique which provides a table of correction coefficients for an image acquired at any arbitrary angle about the patient. The coefficients are generated using a linear least-squares fit between the detected and known locations of a grid of small steel beads which is attached to the XRII (27 cm nominal diameter). We have performed corrections on 100 images obtained during rotation of the gantry through 200 degrees and find that a fifth-order polynomial provides optimum image distortion reduction (mean residual distortion of 0.07 pixels), however, fourth-order polynomials provide sufficient distortion reduction for our application (mean residual displacement of 0.1 pixels). Using sixth-order polynomials does not provide a statistically significant reduction in image distortion. The spatial distribution of residual distortion did not demonstrate any particular pattern over the face of the XRII. Image angle and coefficient angle must be known to within +/- 2 degrees in order to keep the mean residual distortion be approximately 0.5 pixels.

Entities:  

Mesh:

Year:  1997        PMID: 9243472     DOI: 10.1118/1.598013

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  12 in total

Review 1.  Biplane X-ray angiograms, intravascular ultrasound, and 3D visualization of coronary vessels.

Authors:  K R Hoffmann; A Wahle; C Pellot-Barakat; J Sklansky; M Sonka
Journal:  Int J Card Imaging       Date:  1999-12

2.  A practical global distortion correction method for an image intensifier based x-ray fluoroscopy system.

Authors:  Luis F Gutiérrez; Cengizhan Ozturk; Elliot R McVeigh; Robert J Lederman
Journal:  Med Phys       Date:  2008-03       Impact factor: 4.071

Review 3.  Sub-Nyquist acquisition and constrained reconstruction in time resolved angiography.

Authors:  Charles A Mistretta
Journal:  Med Phys       Date:  2011-06       Impact factor: 4.071

4.  Geometric calibration and correction for a lens-coupled detector in x-ray phase-contrast imaging.

Authors:  Alex George; Peter Y Chen; Alejandro Morales-Martinez; Alireza Panna; Andrew A Gomella; Eric E Bennett; Han Wen
Journal:  J Med Imaging (Bellingham)       Date:  2017-03-24

5.  4D digital subtraction angiography: implementation and demonstration of feasibility.

Authors:  B Davis; K Royalty; M Kowarschik; C Rohkohl; E Oberstar; B Aagaard-Kienitz; D Niemann; O Ozkan; C Strother; C Mistretta
Journal:  AJNR Am J Neuroradiol       Date:  2013-04-25       Impact factor: 3.825

6.  Hybrid cone-beam tomographic reconstruction: incorporation of prior anatomical models to compensate for missing data.

Authors:  Ofri Sadowsky; Junghoon Lee; E Grant Sutter; Simon J Wall; Jerry L Prince; Russell H Taylor
Journal:  IEEE Trans Med Imaging       Date:  2010-07-26       Impact factor: 10.048

7.  Volumetric limiting spatial resolution analysis of four-dimensional digital subtraction angiography.

Authors:  Brian J Davis; Erick Oberstar; Kevin Royalty; Sebastian Schafer; Charles Mistretta
Journal:  J Med Imaging (Bellingham)       Date:  2016-01-25

8.  Hierarchical radial basis function networks and local polynomial un-warping for X-ray image intensifier distortion correction: a comparison with global techniques.

Authors:  P Cerveri; C Forlani; A Pedotti; G Ferrigno
Journal:  Med Biol Eng Comput       Date:  2003-03       Impact factor: 3.079

9.  Image intensifier distortion correction for fluoroscopic RSA: the need for independent accuracy assessment.

Authors:  Angela E Kedgley; Anne-Marie V Fox; Thomas R Jenkyn
Journal:  J Appl Clin Med Phys       Date:  2012-01-05       Impact factor: 2.102

Review 10.  Interventional cardiovascular magnetic resonance: still tantalizing.

Authors:  Kanishka Ratnayaka; Anthony Z Faranesh; Michael A Guttman; Ozgur Kocaturk; Christina E Saikus; Robert J Lederman
Journal:  J Cardiovasc Magn Reson       Date:  2008-12-29       Impact factor: 5.364

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.