Literature DB >> 22745209

Quantitative MRI measurements of the Achilles tendon in spondyloarthritis using ultrashort echo times.

R J Hodgson1, N Menon, A J Grainger, P J O'Connor, D McGonagle, P Helliwell, P Emery, M D Robson.   

Abstract

OBJECTIVES: Tendon involvement is common in spondyloarthritis. The MRI signal from the Achilles tendon has been used to quantify mechanical tendinopathy; however, conventional MRI is limited by the short T(2) of normal tendon. Short and ultrashort echo time (UTE) MRI have the potential to better measure signal intensity reflecting changes in T(2) or gadolinium enhancement. Furthermore, UTE images could be used for normalisation to reduce variability. The aim of this work was to investigate such techniques in patients with spondyloarthritis (SpA).
METHODS: The Achilles tendons of 14 healthy volunteers and 24 patients with symptomatic spondyloarthritis were studied. Combined UTE (TE=0.07 ms) and gradient echo (TE=4.9 ms) images were acquired before and after intravenous gadolinium together with pre-contrast gradient echo images (TE=2 ms). The signal intensity from a region of interest in the Achilles tendon above the calcaneus was measured. The relative enhancement at echo times of 0.07 ms (RE(0.1)) and 4.9 ms (RE(5)) were calculated. The ratios of the signal intensities from both 4.9 ms and 2 ms gradient echo images to the signal intensity from the UTE image were calculated (RTE(5) and RTE(2) respectively).
RESULTS: Interobserver intraclass correlation coefficients were excellent (≥0.97). The contrast-to-noise ratio was higher for enhancement on UTE images than on gradient echo images. RE(0.1), RTE(5) and RTE(2) were significantly higher in SpA patients than controls.
CONCLUSION: Signal intensity ratios using UTE images allow quantitative measurements to be made which are sensitive to tendon T(2) or contrast enhancement and which are increased in spondyloarthritis. They therefore have the potential for use as measures of tendon disease in spondyloarthritis.

Entities:  

Mesh:

Year:  2012        PMID: 22745209      PMCID: PMC3474080          DOI: 10.1259/bjr/13555456

Source DB:  PubMed          Journal:  Br J Radiol        ISSN: 0007-1285            Impact factor:   3.039


  24 in total

1.  Interreader agreement in the assessment of magnetic resonance images of rheumatoid arthritis wrist and finger joints--an international multicenter study.

Authors:  M Ostergaard; M Klarlund; M Lassere; P Conaghan; C Peterfy; F McQueen; P O'Connor; R Shnier; N Stewart; D McGonagle; P Emery; H Genant; J Edmonds
Journal:  J Rheumatol       Date:  2001-05       Impact factor: 4.666

2.  Tendon injury and repair after core biopsies in chronic Achilles tendinosis evaluated by serial magnetic resonance imaging.

Authors:  A Shalabi; L Svensson; M Kristoffersen-Wiberg; P Aspelin; T Movin
Journal:  Br J Sports Med       Date:  2004-10       Impact factor: 13.800

3.  Quantitative characterization of the Achilles tendon in cadaveric specimens: T1 and T2* measurements using ultrashort-TE MRI at 3 T.

Authors:  Guinel H Filho; Jiang Du; Byung C Pak; Sheronda Statum; Richard Znamorowski; Parviz Haghighi; Graeme Bydder; Christine B Chung
Journal:  AJR Am J Roentgenol       Date:  2009-03       Impact factor: 3.959

4.  Orientational analysis of the Achilles tendon and enthesis using an ultrashort echo time spectroscopic imaging sequence.

Authors:  Jiang Du; Alan Jing-Tzyh Chiang; Christine B Chung; Sheronda Statum; Richard Znamirowski; Atsushi Takahashi; Graeme M Bydder
Journal:  Magn Reson Imaging       Date:  2009-08-19       Impact factor: 2.546

5.  Prediction of the success of nonoperative treatment of insertional Achilles tendinosis based on MRI.

Authors:  Christopher W Nicholson; Gregory C Berlet; Thomas H Lee
Journal:  Foot Ankle Int       Date:  2007-04       Impact factor: 2.827

6.  Reliability of high-resolution ultrasonography in the assessment of Achilles tendon enthesopathy in seronegative spondyloarthropathies.

Authors:  E Filippucci; S Zehra Aydin; O Karadag; F Salaffi; M Gutierrez; H Direskeneli; W Grassi
Journal:  Ann Rheum Dis       Date:  2009-04-08       Impact factor: 19.103

7.  OMERACT Rheumatoid Arthritis Magnetic Resonance Imaging Studies. Exercise 4: an international multicenter longitudinal study using the RA-MRI Score.

Authors:  Philip Conaghan; Marissa Lassere; Mikkel Østergaard; Charles Peterfy; Fiona McQueen; Philip O'Connor; Paul Bird; Bo Ejbjerg; Mette Klarlund; Ron Shnier; Harry Genant; Paul Emery; John Edmonds
Journal:  J Rheumatol       Date:  2003-06       Impact factor: 4.666

8.  Magnetic resonance imaging of the Achilles tendon using ultrashort TE (UTE) pulse sequences.

Authors:  M D Robson; M Benjamin; P Gishen; G M Bydder
Journal:  Clin Radiol       Date:  2004-08       Impact factor: 2.350

9.  Magnetic resonance imaging of hindfoot involvement in patients with spondyloarthritides: comparison of low-field and high-field strength units.

Authors:  Iris Eshed; Christian E Althoff; Eugen Feist; Kirsten Minden; Tania Schink; Bernd Hamm; Kay-Geert A Hermann
Journal:  Eur J Radiol       Date:  2007-04-26       Impact factor: 3.528

10.  Dynamic contrast-enhanced mr imaging and histopathology in chronic achilles tendinosis. A longitudinal MR study of 15 patients.

Authors:  A Shalabi; M Kristoffersen-Wiberg; N Papadogiannakis; P Aspelin; T Movin
Journal:  Acta Radiol       Date:  2002-03       Impact factor: 1.701

View more
  1 in total

Review 1.  Gluteal Tendinopathy: A Review of Mechanisms, Assessment and Management.

Authors:  Alison Grimaldi; Rebecca Mellor; Paul Hodges; Kim Bennell; Henry Wajswelner; Bill Vicenzino
Journal:  Sports Med       Date:  2015-08       Impact factor: 11.136

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.