Literature DB >> 20639149

A high-frequency, high frame rate duplex ultrasound linear array imaging system for small animal imaging.

Lequan Zhang1, Xiaochen Xu, Changhong Hu, Lei Sun, Jesse T Yen, Jonathan M Cannata, K Kirk Shung.   

Abstract

High-frequency (HF) ultrasound imaging has been shown to be useful for non-invasively imaging anatomical structures of the eye and small animals in biological and pharmaceutical research, achieving superior spatial resolution. Cardiovascular research utilizing mice requires not only realtime B-scan imaging, but also ultrasound Doppler to evaluate both anatomy and blood flow of the mouse heart. This paper reports the development of an HF ultrasound duplex imaging system capable of both B-mode imaging and Doppler flow measurements, using a 64-element linear array. The system included an HF pulsed-wave Doppler module, a 32-channel HF B-mode imaging module, a PC with a 200 MS/s 14-bit A/D card, and real-time LabView software. A 50 dB SNR and a depth of penetration of larger than 12 mm were achieved using a 35-MHz linear array with 50 μm pitch. The two-way beam widths were determined to be 165 to 260 μm and the clutter-energy-to-total-energy ratio (CTR) were 9.1 to 12 dB when the array was electronically focused at different focal points at depths from 4.8 to 9.6 mm. The system is capable of acquiring real-time B-mode images at a rate greater than 400 frames per second (fps) for a 4.8 x 13 mm field of view, using a 30- MHz 64-element linear array with 100 μm pitch. Sample in vivo cardiac high frame rate images and duplex images of mouse hearts are shown to assess its current imaging capability and performance for small animals.

Entities:  

Mesh:

Year:  2010        PMID: 20639149      PMCID: PMC2908919          DOI: 10.1109/TUFFC.2010.1585

Source DB:  PubMed          Journal:  IEEE Trans Ultrason Ferroelectr Freq Control        ISSN: 0885-3010            Impact factor:   2.725


  21 in total

Review 1.  Ultrasound for the visualization and quantification of tumor microcirculation.

Authors:  F S Foster; P N Burns; D H Simpson; S R Wilson; D A Christopher; D E Goertz
Journal:  Cancer Metastasis Rev       Date:  2000       Impact factor: 9.264

Review 2.  Use of positron emission tomography in animal research.

Authors:  S R Cherry; S S Gambhir
Journal:  ILAR J       Date:  2001

Review 3.  High resolution X-ray computed tomography: an emerging tool for small animal cancer research.

Authors:  M J Paulus; S S Gleason; S J Kennel; P R Hunsicker; D K Johnson
Journal:  Neoplasia       Date:  2000 Jan-Apr       Impact factor: 5.715

4.  Pulsed Doppler signal processing for use in mice: applications.

Authors:  Anilkumar K Reddy; George E Taffet; Yi-Heng Li; Sang-Wook Lim; Thuy T Pham; Jennifer S Pocius; Mark L Entman; Lloyd H Michael; Craig J Hartley
Journal:  IEEE Trans Biomed Eng       Date:  2005-10       Impact factor: 4.538

5.  A low-cost bipolar pulse generator for high-frequency ultrasound applications.

Authors:  Xiaochen Xu; Jesse T Yen; K Kirk Shung
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2007-02       Impact factor: 2.725

6.  High-frequency ultrasound Doppler system for biomedical applications with a 30-MHz linear array.

Authors:  Xiaochen Xu; Lei Sun; Jonathan M Cannata; Jesse T Yen; K Kirk Shung
Journal:  Ultrasound Med Biol       Date:  2007-11-12       Impact factor: 2.998

7.  The design of protection circuitry for high-frequency ultrasound imaging systems.

Authors:  G R Lockwood; J W Hunt; F S Foster
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  1991       Impact factor: 2.725

8.  A new 15-50 MHz array-based micro-ultrasound scanner for preclinical imaging.

Authors:  F Stuart Foster; James Mehi; Marc Lukacs; Desmond Hirson; Chris White; Chris Chaggares; Andrew Needles
Journal:  Ultrasound Med Biol       Date:  2009-08-03       Impact factor: 2.998

9.  A high-frequency pulsed-wave Doppler ultrasound system for the detection and imaging of blood flow in the microcirculation.

Authors:  D A Christopher; P N Burns; B G Starkoski; F S Foster
Journal:  Ultrasound Med Biol       Date:  1997       Impact factor: 2.998

10.  Ultrahigh frame rate retrospective ultrasound microimaging and blood flow visualization in mice in vivo.

Authors:  Emmanuel Chérin; Ross Williams; Andrew Needles; Godwin Liu; Christopher White; Allison S Brown; Yu-Qing Zhou; F Stuart Foster
Journal:  Ultrasound Med Biol       Date:  2006-05       Impact factor: 2.998

View more
  8 in total

1.  Analysis and Design of High-Frequency 1-D CMUT Imaging Arrays in Noncollapsed Mode.

Authors:  Evren Fatih Arkan; F Levent Degertekin
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2018-12-17       Impact factor: 2.725

2.  Hemodynamics and ventricular function in a zebrafish model of injury and repair.

Authors:  Juhyun Lee; Hung Cao; Bong Jin Kang; Nelson Jen; Fei Yu; Chia-An Lee; Peng Fei; Jinhyoung Park; Shadi Bohlool; Lian Lash-Rosenberg; K Kirk Shung; Tzung K Hsiai
Journal:  Zebrafish       Date:  2014-10       Impact factor: 1.985

3.  Development of a 64 channel ultrasonic high frequency linear array imaging system.

Authors:  ChangHong Hu; Lequan Zhang; Jonathan M Cannata; Jesse Yen; K Kirk Shung
Journal:  Ultrasonics       Date:  2011-05-27       Impact factor: 2.890

4.  A flexible annular-array imaging platform for micro-ultrasound.

Authors:  Weibao Qiu; Yanyan Yu; Hamid Reza Chabok; Cheng Liu; Fu Keung Tsang; Qifa Zhou; K Kirk Shung; Hairong Zheng; Lei Sun
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2013-01       Impact factor: 2.725

5.  mTORC1 Deficiency Modifies Volume Homeostatic Responses to Dietary Sodium in a Sex-Specific Manner.

Authors:  Danielle L Brooks; Amanda E Garza; Ezgi Caliskan Guzelce; Shadi K Gholami; Thitinan Treesaranuwattana; Stephen Maris; Sanjay Ranjit; Chee Sin Tay; Jessica M Lee; Jose R Romero; Gail K Adler; Luminita H Pojoga; Gordon H Williams
Journal:  Endocrinology       Date:  2020-05-01       Impact factor: 4.736

6.  PIN-PMN-PT Single Crystal 1-3 Composite-based 20 MHz Ultrasound Phased Array.

Authors:  Wei Zhou; Tao Zhang; Jun Ou-Yang; Xiaofei Yang; Dawei Wu; Benpeng Zhu
Journal:  Micromachines (Basel)       Date:  2020-05-21       Impact factor: 2.891

7.  Sex-specific differences in endoplasmic reticulum aminopeptidase 1 modulation influence blood pressure and renin-angiotensin system responses.

Authors:  Sanjay Ranjit; Jian Yao Wong; Jia W Tan; Chee Sin Tay; Jessica M Lee; Kelly Yin Han Wong; Luminita H Pojoga; Danielle L Brooks; Amanda E Garza; Stephen A Maris; Isis Akemi Katayama; Jonathan S Williams; Alicia Rivera; Gail K Adler; Gordon H Williams; Jose R Romero
Journal:  JCI Insight       Date:  2019-11-01

8.  Early Detection of Drug-Induced Renal Hemodynamic Dysfunction Using Sonographic Technology in Rats.

Authors:  Sudeshna Fisch; Ronglih Liao; Li-Li Hsiao; Tzongshi Lu
Journal:  J Vis Exp       Date:  2016-03-11       Impact factor: 1.355

  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.