Literature DB >> 17328342

A low-cost bipolar pulse generator for high-frequency ultrasound applications.

Xiaochen Xu, Jesse T Yen, K Kirk Shung.   

Abstract

A design of a low-cost bipolar pulse generator for high-frequency (HF) ultrasound applications is presented. The pulse generator can produce N cycle (1-255 cycles) bipolar pulses with center frequency over 60 MHz. The measured pulse amplitude was over 160 Vpp, and the pulse ringing was less than 0.3 Vpp (i.e., signal-to-ring ratio is 55 dB). The pulser can be used in high-frequency ultrasound Doppler and B-mode imaging applications with arrays.

Mesh:

Year:  2007        PMID: 17328342     DOI: 10.1109/tuffc.2007.259

Source DB:  PubMed          Journal:  IEEE Trans Ultrason Ferroelectr Freq Control        ISSN: 0885-3010            Impact factor:   2.725


  10 in total

1.  High-frequency ultrasound Doppler system for biomedical applications with a 30-MHz linear array.

Authors:  Xiaochen Xu; Lei Sun; Jonathan M Cannata; Jesse T Yen; K Kirk Shung
Journal:  Ultrasound Med Biol       Date:  2007-11-12       Impact factor: 2.998

2.  In vivo cardiac imaging of adult zebrafish using high frequency ultrasound (45-75 MHz).

Authors:  Lei Sun; Ching-Ling Lien; Xiaochen Xu; K Kirk Shung
Journal:  Ultrasound Med Biol       Date:  2007-09-07       Impact factor: 2.998

3.  Acoustic trapping with a high frequency linear phased array.

Authors:  Fan Zheng; Ying Li; Hsiu-Sheng Hsu; Changgeng Liu; Chi Tat Chiu; Changyang Lee; Hyung Ham Kim; K Kirk Shung
Journal:  Appl Phys Lett       Date:  2012-11-21       Impact factor: 3.791

4.  An open system for intravascular ultrasound imaging.

Authors:  Weibao Qiu; Yan Chen; Xiang Li; Yanyan Yu; Wang Fai Cheng; Fu Keung Tsang; Qifa Zhou; K Kirk Shung; Jiyan Dai; Lei Sun
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2012-10       Impact factor: 2.725

5.  A high-frequency, high frame rate duplex ultrasound linear array imaging system for small animal imaging.

Authors:  Lequan Zhang; Xiaochen Xu; Changhong Hu; Lei Sun; Jesse T Yen; Jonathan M Cannata; K Kirk Shung
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2010-07       Impact factor: 2.725

6.  Stand-alone front-end system for high- frequency, high-frame-rate coded excitation ultrasonic imaging.

Authors:  Jinhyoung Park; Changhong Hu; K Kirk Shung
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2011-12       Impact factor: 2.725

7.  A reconfigurable arbitrary waveform generator using PWM modulation for ultrasound research.

Authors:  Amauri A Assef; Joaquim M Maia; Fábio K Schneider; Vera L S N Button; Eduardo T Costa
Journal:  Biomed Eng Online       Date:  2013-03-20       Impact factor: 2.819

8.  Multiple-site hemodynamic analysis of Doppler ultrasound with an adaptive color relation classifier for arteriovenous access occlusion evaluation.

Authors:  Jian-Xing Wu; Yi-Chun Du; Ming-Jui Wu; Chien-Ming Li; Chia-Hung Lin; Tainsong Chen
Journal:  ScientificWorldJournal       Date:  2014-04-30

9.  Improvement of Ultrasonic Pulse Generator for Automatic Pipeline Inspection.

Authors:  Noé Amir Rodríguez-Olivares; José Vicente Cruz-Cruz; Alejandro Gómez-Hernández; Rodrigo Hernández-Alvarado; Luciano Nava-Balanzar; Tomás Salgado-Jiménez; Jorge Alberto Soto-Cajiga
Journal:  Sensors (Basel)       Date:  2018-09-05       Impact factor: 3.576

10.  A Single-Chip High-Voltage Integrated Actuator for Biomedical Ultrasound Scanners.

Authors:  Chin Hsia; Yi-Chi Hsiao; Yen-Chung Huang
Journal:  Sensors (Basel)       Date:  2019-11-20       Impact factor: 3.576

  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.