Literature DB >> 17993243

High-frequency ultrasound Doppler system for biomedical applications with a 30-MHz linear array.

Xiaochen Xu1, Lei Sun, Jonathan M Cannata, Jesse T Yen, K Kirk Shung.   

Abstract

In this paper, we report the development of the first high-frequency (HF) pulsed-wave Doppler system using a 30-MHz linear array transducer to assess the cardiovascular functions in small animals. This array-based pulsed-wave Doppler system included a 16-channel HF analog beamformer, a HF pulsed-wave Doppler module, timing circuits, HF bipolar pulsers and analog front ends. The beamformed echoes acquired by the 16-channel analog beamformer were fed directly to the HF pulsed-wave Doppler module. Then the in-phase and quadrature-phase (IQ) audio Doppler signals were digitized by either a sound card or a Gage digitizer and stored in a personal computer. The Doppler spectrogram was displayed on a personal computer in real time. The two-way beamwidths were determined to be 160 microm to 320 microm when the array was electronically focused at different focal points at depths from 5 to 10 mm. A micro-flow phantom, consisting of a polyimide tube with an inner diameter of 127 microm and the wire phantom were used to evaluate and calibrate the system. The results show that the system is capable of detecting motion velocity of the wire phantom as low as 0.1 mm/s, and detecting blood-mimicking flow velocity in the 127-microm tube lower than 7 mm/s. The system was subsequently used to measure the blood flow in vivo in two mouse abdominal superficial vessels, with diameters of approximately 200 microm, and a mouse aorta close to the heart. These results demonstrated that this system may become an indispensable part of the current HF array-based imaging systems for small animal studies.

Entities:  

Mesh:

Year:  2007        PMID: 17993243      PMCID: PMC2330166          DOI: 10.1016/j.ultrasmedbio.2007.09.012

Source DB:  PubMed          Journal:  Ultrasound Med Biol        ISSN: 0301-5629            Impact factor:   2.998


  21 in total

Review 1.  Ultrasound for the visualization and quantification of tumor microcirculation.

Authors:  F S Foster; P N Burns; D H Simpson; S R Wilson; D A Christopher; D E Goertz
Journal:  Cancer Metastasis Rev       Date:  2000       Impact factor: 9.264

2.  Time-frequency analysis for pulse driven ultrasonic microscopy for biological tissue characterization.

Authors:  N Hozumi; R Yamashita; C-K Lee; M Nagao; K Kobayashi; Y Saijo; M Tanaka; N Tanaka; S Ohtsuki
Journal:  Ultrasonics       Date:  2004-04       Impact factor: 2.890

3.  Pulsed Doppler signal processing for use in mice: applications.

Authors:  Anilkumar K Reddy; George E Taffet; Yi-Heng Li; Sang-Wook Lim; Thuy T Pham; Jennifer S Pocius; Mark L Entman; Lloyd H Michael; Craig J Hartley
Journal:  IEEE Trans Biomed Eng       Date:  2005-10       Impact factor: 4.538

4.  A low-cost bipolar pulse generator for high-frequency ultrasound applications.

Authors:  Xiaochen Xu; Jesse T Yen; K Kirk Shung
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2007-02       Impact factor: 2.725

5.  The design of protection circuitry for high-frequency ultrasound imaging systems.

Authors:  G R Lockwood; J W Hunt; F S Foster
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  1991       Impact factor: 2.725

6.  A high-frequency pulsed-wave Doppler ultrasound system for the detection and imaging of blood flow in the microcirculation.

Authors:  D A Christopher; P N Burns; B G Starkoski; F S Foster
Journal:  Ultrasound Med Biol       Date:  1997       Impact factor: 2.998

7.  A new ultrasound instrument for in vivo microimaging of mice.

Authors:  F S Foster; M Y Zhang; Y Q Zhou; G Liu; J Mehi; E Cherin; K A Harasiewicz; B G Starkoski; L Zan; D A Knapik; S L Adamson
Journal:  Ultrasound Med Biol       Date:  2002-09       Impact factor: 2.998

8.  Characterization of high-frequency, single-element focused transducers with wire target and hydrophone.

Authors:  Bin Huang; K Kirk Shung
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2005-09       Impact factor: 2.725

9.  Ultrahigh frame rate retrospective ultrasound microimaging and blood flow visualization in mice in vivo.

Authors:  Emmanuel Chérin; Ross Williams; Andrew Needles; Godwin Liu; Christopher White; Allison S Brown; Yu-Qing Zhou; F Stuart Foster
Journal:  Ultrasound Med Biol       Date:  2006-05       Impact factor: 2.998

10.  Intermittent pressure overload triggers hypertrophy-independent cardiac dysfunction and vascular rarefaction.

Authors:  Cinzia Perrino; Sathyamangla V Naga Prasad; Lan Mao; Takahisa Noma; Zhen Yan; Hyung-Suk Kim; Oliver Smithies; Howard A Rockman
Journal:  J Clin Invest       Date:  2006-06       Impact factor: 14.808

View more
  7 in total

1.  High-overtone self-focusing acoustic transducers for high-frequency ultrasonic Doppler.

Authors:  Jie Zhu; Chuangyuan Lee; Eun Sok Kim; Dawei Wu; Changhong Hu; Qifa Zhou; K Kirk Shung; Gaofeng Wang; Hongyu Yu
Journal:  Ultrasonics       Date:  2010-02-08       Impact factor: 2.890

2.  A high-frequency, high frame rate duplex ultrasound linear array imaging system for small animal imaging.

Authors:  Lequan Zhang; Xiaochen Xu; Changhong Hu; Lei Sun; Jesse T Yen; Jonathan M Cannata; K Kirk Shung
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2010-07       Impact factor: 2.725

3.  A flexible annular-array imaging platform for micro-ultrasound.

Authors:  Weibao Qiu; Yanyan Yu; Hamid Reza Chabok; Cheng Liu; Fu Keung Tsang; Qifa Zhou; K Kirk Shung; Hairong Zheng; Lei Sun
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2013-01       Impact factor: 2.725

4.  Calibrating Doppler imaging of preterm intracerebral circulation using a microvessel flow phantom.

Authors:  Fleur A Camfferman; Ginette M Ecury-Goossen; Jhuresy E La Roche; Nico de Jong; Willem van 't Leven; Hendrik J Vos; Martin D Verweij; Kazem Nasserinejad; Filip Cools; Paul Govaert; Jeroen Dudink
Journal:  Front Hum Neurosci       Date:  2015-01-13       Impact factor: 3.169

5.  acoustic assessment of a konjac–carrageenan tissue-mimicking material aT 5–60 MHZ.

Authors:  David A Kenwright; Neelaksh Sadhoo; Srinath Rajagopal; Tom Anderson; Carmel M Moran; Patrick W Hadoke; Gillian A Gray; Bajram Zeqiri; Peter R Hoskins
Journal:  Ultrasound Med Biol       Date:  2014-12       Impact factor: 2.998

6.  Multiple-site hemodynamic analysis of Doppler ultrasound with an adaptive color relation classifier for arteriovenous access occlusion evaluation.

Authors:  Jian-Xing Wu; Yi-Chun Du; Ming-Jui Wu; Chien-Ming Li; Chia-Hung Lin; Tainsong Chen
Journal:  ScientificWorldJournal       Date:  2014-04-30

7.  Doppler optical coherence tomography for energy seal evaluation and comparison to visual evaluation.

Authors:  Andrew Marques; Robnier Reyes; Christopher R Pasarikovski; Chaoliang Chen; Joel Ramjist; Xijia Gu; Victor Yang
Journal:  J Biomed Opt       Date:  2020-03       Impact factor: 3.170

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.