Literature DB >> 20619569

Cumulative exposure to ionizing radiation from diagnostic and therapeutic cardiac imaging procedures: a population-based analysis.

Jersey Chen1, Andrew J Einstein, Reza Fazel, Harlan M Krumholz, Yongfei Wang, Joseph S Ross, Henry H Ting, Nilay D Shah, Khurram Nasir, Brahmajee K Nallamothu.   

Abstract

OBJECTIVES: The purpose of this study was to describe radiation exposure from cardiac imaging procedures over time in a general population.
BACKGROUND: Cardiac imaging procedures frequently expose patients to ionizing radiation, but their contribution to effective doses of radiation in the general population is unknown.
METHODS: We used administrative claims to identify cardiac imaging procedures performed from 2005 to 2007 in 952,420 nonelderly insured adults in 5 U.S. health care markets. We estimated 3-year cumulative effective doses of radiation in millisieverts from these procedures We then calculated population-based annual rates of radiation exposure to effective doses < or =3 mSv/year (background level of radiation from natural sources), >3 to 20 mSv/year, or >20 mSv/year (upper annual limit for occupational exposure averaged over 5 years).
RESULTS: A total of 90,121 (9.5%) individuals underwent at least 1 cardiac imaging procedure using radiation. Among patients who underwent > or =1 cardiac imaging procedures, the mean cumulative effective dose over 3 years was 23.1 mSv (range 1.5 to 543.7 mSv). Myocardial perfusion imaging accounted for 74% of the cumulative effective dose. Overall, 47.8% of cardiac imaging procedures were performed in physician offices; this proportion was higher for myocardial perfusion imaging (74.8%) and cardiac computed tomography studies (76.5%). The annual population-based rate of receiving an effective dose of >3 to 20 mSv/year was 89.0 per 1,000; and 3.3 per 1,000 for cumulative doses >20 mSv/year. Annual effective doses increased with age and were generally higher among men.
CONCLUSIONS: Cardiac imaging procedures lead to substantial radiation exposure and effective doses for many patients in the U.S. Copyright 2010 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.

Entities:  

Mesh:

Year:  2010        PMID: 20619569      PMCID: PMC2952402          DOI: 10.1016/j.jacc.2010.05.014

Source DB:  PubMed          Journal:  J Am Coll Cardiol        ISSN: 0735-1097            Impact factor:   24.094


  38 in total

1.  Multislice helical CT of the heart with retrospective ECG gating: reduction of radiation exposure by ECG-controlled tube current modulation.

Authors:  Tobias F Jakobs; Christoph R Becker; Bernd Ohnesorge; Thomas Flohr; Christoph Suess; Uwe J Schoepf; Maximilian F Reiser
Journal:  Eur Radiol       Date:  2002-02-21       Impact factor: 5.315

2.  Accurate assessment of patient effective radiation dose and associated detriment risk from radiofrequency catheter ablation procedures.

Authors:  K Perisinakis; J Damilakis; N Theocharopoulos; E Manios; P Vardas; N Gourtsoyiannis
Journal:  Circulation       Date:  2001-07-03       Impact factor: 29.690

3.  The 2007 Recommendations of the International Commission on Radiological Protection. ICRP publication 103.

Authors: 
Journal:  Ann ICRP       Date:  2007

4.  The application of effective dose to medical exposures.

Authors:  Colin J Martin
Journal:  Radiat Prot Dosimetry       Date:  2007-10-20       Impact factor: 0.972

5.  Prospectively gated transverse coronary CT angiography versus retrospectively gated helical technique: improved image quality and reduced radiation dose.

Authors:  James P Earls; Elise L Berman; Bruce A Urban; Charlene A Curry; Judith L Lane; Robert S Jennings; Colin C McCulloch; Jiang Hsieh; John H Londt
Journal:  Radiology       Date:  2008-01-14       Impact factor: 11.105

6.  Exposure to low-dose ionizing radiation from medical imaging procedures.

Authors:  Reza Fazel; Harlan M Krumholz; Yongfei Wang; Joseph S Ross; Jersey Chen; Henry H Ting; Nilay D Shah; Khurram Nasir; Andrew J Einstein; Brahmajee K Nallamothu
Journal:  N Engl J Med       Date:  2009-08-27       Impact factor: 91.245

7.  Evaluation of patient and staff doses during various CT fluoroscopy guided interventions.

Authors:  Nico Buls; Jessica Pagés; Johan de Mey; Michel Osteaux
Journal:  Health Phys       Date:  2003-08       Impact factor: 1.316

8.  Effective techniques for reduction of radiation dosage to patients undergoing invasive cardiac procedures.

Authors:  E Kuon; C Glaser; J B Dahm
Journal:  Br J Radiol       Date:  2003-06       Impact factor: 3.039

9.  Cancer risks attributable to low doses of ionizing radiation: assessing what we really know.

Authors:  David J Brenner; Richard Doll; Dudley T Goodhead; Eric J Hall; Charles E Land; John B Little; Jay H Lubin; Dale L Preston; R Julian Preston; Jerome S Puskin; Elaine Ron; Rainer K Sachs; Jonathan M Samet; Richard B Setlow; Marco Zaider
Journal:  Proc Natl Acad Sci U S A       Date:  2003-11-10       Impact factor: 11.205

10.  The American College of Radiology white paper on radiation dose in medicine:deep impact on the practice of cardiovascular imaging.

Authors:  Eugenio Picano; Eliseo Vano; Richard Semelka; Dieter Regulla
Journal:  Cardiovasc Ultrasound       Date:  2007-10-31       Impact factor: 2.062

View more
  63 in total

1.  Evidence for prospective ECG-triggering coronary CT angiography in routine practice.

Authors:  Ali Salavati; Frank J Rybicki
Journal:  Int J Cardiovasc Imaging       Date:  2012-02-09       Impact factor: 2.357

2.  DNA double-strand breaks as potential indicators for the biological effects of ionising radiation exposure from cardiac CT and conventional coronary angiography: a randomised, controlled study.

Authors:  Dominik Geisel; Elke Zimmermann; Matthias Rief; Johannes Greupner; Michael Laule; Fabian Knebel; Bernd Hamm; Marc Dewey
Journal:  Eur Radiol       Date:  2012-04-17       Impact factor: 5.315

3.  Evaluation of coronary angiographic projections to balance the clinical yield with the radiation risk.

Authors:  I R Smith; J Cameron; K L Mengersen; J T Rivers
Journal:  Br J Radiol       Date:  2012-04-18       Impact factor: 3.039

4.  Multiple testing, cumulative radiation dose, and clinical indications in patients undergoing myocardial perfusion imaging.

Authors:  Andrew J Einstein; Shepard D Weiner; Adam Bernheim; Michal Kulon; Sabahat Bokhari; Lynne L Johnson; Jeffrey W Moses; Stephen Balter
Journal:  JAMA       Date:  2010-11-15       Impact factor: 56.272

5.  Feasibility of stress only rubidium-82 PET myocardial perfusion imaging.

Authors:  Sean R McMahon; Janusz Kikut; Richard G Pinckney; Friederike K Keating
Journal:  J Nucl Cardiol       Date:  2013-08-17       Impact factor: 5.952

6.  Flexible Modeling of the Association Between Cumulative Exposure to Low-Dose Ionizing Radiation From Cardiac Procedures and Risk of Cancer in Adults With Congenital Heart Disease.

Authors:  Coraline Danieli; Sarah Cohen; Aihua Liu; Louise Pilote; Liming Guo; Marie-Eve Beauchamp; Ariane J Marelli; Michal Abrahamowicz
Journal:  Am J Epidemiol       Date:  2019-08-01       Impact factor: 4.897

7.  Stress Perfusion Cardiac Magnetic Resonance Imaging Effectively Risk Stratifies Diabetic Patients With Suspected Myocardial Ischemia.

Authors:  Bobak Heydari; Yu-Hsiang Juan; Hui Liu; Siddique Abbasi; Ravi Shah; Ron Blankstein; Michael Steigner; Michael Jerosch-Herold; Raymond Y Kwong
Journal:  Circ Cardiovasc Imaging       Date:  2016-04       Impact factor: 7.792

Review 8.  The future of SPECT MPI: time and dose reduction.

Authors:  Milena J Henzlova; W Lane Duvall
Journal:  J Nucl Cardiol       Date:  2011-08       Impact factor: 5.952

9.  Multi-detector computed tomography coronary angiography: the incidental lung findings.

Authors:  Khaled Alfakih; Mathew Budoff
Journal:  J R Soc Med       Date:  2011-02       Impact factor: 5.344

10.  Drivers of radiation dose reduction with myocardial perfusion imaging: A large health system experience.

Authors:  Firas J Al Badarin; John A Spertus; Timothy M Bateman; Krishna K Patel; Eric V Burgett; Kevin F Kennedy; Randall C Thompson
Journal:  J Nucl Cardiol       Date:  2019-01-31       Impact factor: 5.952

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.