I R Smith1, J Cameron, K L Mengersen, J T Rivers. 1. St. Andrew's Medical Institute, St Andrew's War Memorial Hospital, Brisbane, QLD, Australia. ismith@sawmh.com.au
Abstract
OBJECTIVE: Radiation safety principles dictate that imaging procedures should minimise the radiation risks involved, without compromising diagnostic performance. This study aims to define a core set of views that maximises clinical information yield for minimum radiation risk. Angiographers would supplement these views as clinically indicated. METHODS: An algorithm was developed to combine published data detailing the quality of information derived for the major coronary artery segments through the use of a common set of views in angiography with data relating to the dose-area product and scatter radiation associated with these views. RESULTS: The optimum view set for the left coronary system comprised four views: left anterior oblique (LAO) with cranial (Cr) tilt, shallow right anterior oblique (AP-RAO) with caudal (Ca) tilt, RAO with Ca tilt and AP-RAO with Cr tilt. For the right coronary system three views were identified: LAO with Cr tilt, RAO and AP-RAO with Cr tilt. An alternative left coronary view set including a left lateral achieved minimally superior efficiency (<5%), but with an ~8% higher radiation dose to the patient and 40% higher cardiologist dose. CONCLUSION: This algorithm identifies a core set of angiographic views that optimises the information yield and minimises radiation risk. This basic data set would be supplemented by additional clinically determined views selected by the angiographer for each case. The decision to use additional views for diagnostic angiography and interventions would be assisted by referencing a table of relative radiation doses for the views being considered.
OBJECTIVE: Radiation safety principles dictate that imaging procedures should minimise the radiation risks involved, without compromising diagnostic performance. This study aims to define a core set of views that maximises clinical information yield for minimum radiation risk. Angiographers would supplement these views as clinically indicated. METHODS: An algorithm was developed to combine published data detailing the quality of information derived for the major coronary artery segments through the use of a common set of views in angiography with data relating to the dose-area product and scatter radiation associated with these views. RESULTS: The optimum view set for the left coronary system comprised four views: left anterior oblique (LAO) with cranial (Cr) tilt, shallow right anterior oblique (AP-RAO) with caudal (Ca) tilt, RAO with Ca tilt and AP-RAO with Cr tilt. For the right coronary system three views were identified: LAO with Cr tilt, RAO and AP-RAO with Cr tilt. An alternative left coronary view set including a left lateral achieved minimally superior efficiency (<5%), but with an ~8% higher radiation dose to the patient and 40% higher cardiologist dose. CONCLUSION: This algorithm identifies a core set of angiographic views that optimises the information yield and minimises radiation risk. This basic data set would be supplemented by additional clinically determined views selected by the angiographer for each case. The decision to use additional views for diagnostic angiography and interventions would be assisted by referencing a table of relative radiation doses for the views being considered.
Authors: Jersey Chen; Andrew J Einstein; Reza Fazel; Harlan M Krumholz; Yongfei Wang; Joseph S Ross; Henry H Ting; Nilay D Shah; Khurram Nasir; Brahmajee K Nallamothu Journal: J Am Coll Cardiol Date: 2010-07-09 Impact factor: 24.094
Authors: Vitor O Gomes; Patricia Blaya; Carlos E Poli de Figueiredo; Waldomiro Manfroi; Paulo Caramori Journal: J Invasive Cardiol Date: 2003-06 Impact factor: 2.022
Authors: Eberhard Kuon; Johannes B Dahm; Klaus Empen; Daniel M Robinson; Gereon Reuter; Michael Wucherer Journal: J Am Coll Cardiol Date: 2004-10-06 Impact factor: 24.094
Authors: Gianluca De Rubeis; Adriane E Napp; Peter Schlattmann; Jacob Geleijns; Michael Laule; Henryk Dreger; Klaus Kofoed; Mathias Sørgaard; Thomas Engstrøm; Hans Henrik Tilsted; Alberto Boi; Michele Porcu; Stefano Cossa; José F Rodríguez-Palomares; Filipa Xavier Valente; Albert Roque; Gudrun Feuchtner; Fabian Plank; Cyril Štěchovský; Theodor Adla; Stephen Schroeder; Thomas Zelesny; Matthias Gutberlet; Michael Woinke; Mihály Károlyi; Júlia Karády; Patrick Donnelly; Peter Ball; Jonathan Dodd; Mark Hensey; Massimo Mancone; Andrea Ceccacci; Marina Berzina; Ligita Zvaigzne; Gintare Sakalyte; Algidas Basevičius; Małgorzata Ilnicka-Suckiel; Donata Kuśmierz; Rita Faria; Vasco Gama-Ribeiro; Imre Benedek; Teodora Benedek; Filip Adjić; Milenko Čanković; Colin Berry; Christian Delles; Erica Thwaite; Gershan Davis; Juhani Knuuti; Mikko Pietilä; Cezary Kepka; Mariusz Kruk; Radosav Vidakovic; Aleksandar N Neskovic; Iñigo Lecumberri; Ignacio Diez Gonzales; Balazs Ruzsics; Mike Fisher; Marc Dewey; Marco Francone Journal: Eur Radiol Date: 2019-12-16 Impact factor: 5.315
Authors: Yusuf Samet Yaras; Sarp Satir; Cagla Ozsoy; Rajiv Ramasawmy; Adrienne E Campbell-Washburn; Robert J Lederman; Ozgur Kocaturk; F Levent Degertekin Journal: IEEE Trans Biomed Eng Date: 2018-09-05 Impact factor: 4.538