The x-ray light valve: a low-cost, digital radiographic imaging system--spatial resolution.

Robert D MacDougall1, Ivaylo Koprinarov, J A Rowlands.   

Abstract

An x-ray light valve (XLV) coupled with an optical scanner has the potential to meet the need for a low-cost, high quality digital imaging system for general radiography. The XLV/scanner concept combines three well-established, and hence, low-cost technologies: An amorphous selenium (a-Se) layer as an x-ray-to-charge transducer, a liquid crystal (LC) cell as an analog display, and an optical scanner for image digitization. The XLV consists of an a-Se layer and LC cell in a sandwich structure which produces an optical image in the LC layer upon x-ray exposure. The XLV/scanner system consists of an XLV in combination with an optical scanner for image readout. Here, the effect of each component on the spatial resolution of an XLV/scanner system is investigated. A theoretical model of spatial resolution of an XLV is presented based on calculations of the modulation transfer function (MTF) for a-Se and a LC cell. From these component MTFs, the theoretical MTF of the XLV is derived. The model was validated by experiments on a prototype XLV/scanner system. The MTF of the scanner alone was obtained by scanning an optical test target and the MTF of the XLV/scanner system was measured using x rays. From the measured MTF of the scanner, the theoretical MTF of the XLV/scanner system was established and compared with the experimental results. Good general agreement exists between experimental and theoretical results in the frequency range of interest for general radiography, although the theoretical curves slightly overstate the measured MTFs. The experimental MTF of the XLV was compared with the MTF of two clinical systems and was shown to have the capability to exceed the resolution of flat-panel detectors. From this, the authors can conclude that the XLV has an adequate resolution for general radiography. The XLV/scanner also has the potential to eliminate aliasing while maintaining a MTF that exceeds that of a flat-panel imager.

Entities:  

Mesh:

Year:  2008        PMID: 18841872      PMCID: PMC2673658          DOI: 10.1118/1.2968093

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  16 in total

1.  Cone-beam computed tomography with a flat-panel imager: initial performance characterization.

Authors:  D A Jaffray; J H Siewerdsen
Journal:  Med Phys       Date:  2000-06       Impact factor: 4.071

2.  An experimental comparison of detector performance for direct and indirect digital radiography systems.

Authors:  Ehsan Samei; Michael J Flynn
Journal:  Med Phys       Date:  2003-04       Impact factor: 4.071

Review 3.  The physics of computed radiography.

Authors:  J A Rowlands
Journal:  Phys Med Biol       Date:  2002-12-07       Impact factor: 3.609

4.  Evaluation of the imaging properties of an amorphous selenium-based flat panel detector for digital fluoroscopy.

Authors:  D C Hunt; O Tousignant; J A Rowlands
Journal:  Med Phys       Date:  2004-05       Impact factor: 4.071

5.  Semiempirical model for generating tungsten target x-ray spectra.

Authors:  D M Tucker; G T Barnes; D P Chakraborty
Journal:  Med Phys       Date:  1991 Mar-Apr       Impact factor: 4.071

6.  Signal and noise transfer properties of photoelectric interactions in diagnostic x-ray imaging detectors.

Authors:  G Hajdok; J Yao; J J Battista; I A Cunningham
Journal:  Med Phys       Date:  2006-10       Impact factor: 4.071

7.  The x-ray light valve: a low-cost digital radiographic imaging system.

Authors:  Ivaylo Koprinarov; Christie Ann Webster; Robert D MacDougall; J A Rowlands
Journal:  Med Phys       Date:  2007-12       Impact factor: 4.071

8.  The x-ray light valve: a potentially low-cost, digital radiographic imaging system-concept and implementation considerations.

Authors:  Christie Ann Webster; Ivaylo Koprinarov; Stephen Germann; J A Rowlands
Journal:  Med Phys       Date:  2008-03       Impact factor: 4.071

9.  The x-ray light valve: a potentially low-cost, digital radiographic imaging system--a liquid crystal cell design for chest radiography.

Authors:  Timothy C Szeto; Christie Ann Webster; Ivaylo Koprinarov; J A Rowlands
Journal:  Med Phys       Date:  2008-03       Impact factor: 4.071

10.  Digital radiography of subtle pulmonary abnormalities: an ROC study of the effect of pixel size on observer performance.

Authors:  H MacMahon; C J Vyborny; C E Metz; K Doi; V Sabeti; S L Solomon
Journal:  Radiology       Date:  1986-01       Impact factor: 11.105

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.