Measurement of cement thickness under lithium disilicate crowns using an impression material technique.

Sven Reich1, Sophia Uhlen, Stephan Gozdowski, Ulrich Lohbauer.   

Abstract

According to the literature, marginal gaps below 120 μm are recommended for conventionally cemented crown restorations. Therefore, the null hypothesis tested was as follows: the upper bound of the 95% confidence interval of the marginal accuracy of chair-side generated lithium disilicate crowns lies below 120 μm. Prior to definite insertion, the accuracy of 20 lithium disilicate crowns (e.max CAD LT) was evaluated by a replica technique. A light-body silicone was used to document the gap between crown and abutment. The thickness of the light-body silicone layer was examined under microscope (MM40, Nikon Corp., Tokyo, Japan; magnification, ×50) at four different landmarks (LM): LM1 = marginal discrepancy, LM2 = mid-axial discrepancy of the inner crown surface, LM3 = axio-occlusal discrepancy, and LM4 = mid-occlusal discrepancy. At LM1, the mean marginal discrepancy revealed 100 μm (SD, ±61 μm); the median was 81 μm. The lower bound of the 95% confidence interval was 90 μm, and the upper bound was 110 μm. The means of internal gaps at LM2, LM3, and LM4 showed 148 μm (SD, ±61 μm), 227 μm (SD, ±83 μm), and 284 μm (SD, ±95 μm), respectively. The lower bounds of the 95% confidence interval revealed values between 137 μm (LM2) and 269 μm (LM4). The upper bounds were between 158 μm (LM2) and 300 μm (LM4). The null hypothesis was not rejected. Within the limits of the study, the chair-side generated lithium disilicate crowns exhibited a sufficient clinical accuracy.

Entities:  

Mesh:

Substances:

Year:  2010        PMID: 20461424     DOI: 10.1007/s00784-010-0414-x

Source DB:  PubMed          Journal:  Clin Oral Investig        ISSN: 1432-6981            Impact factor:   3.573


  24 in total

1.  Effects of cement, cement space, marginal design, seating aid materials, and seating force on crown cementation.

Authors:  C J Wang; P L Millstein; D Nathanson
Journal:  J Prosthet Dent       Date:  1992-06       Impact factor: 3.426

Review 2.  Considerations in measurement of marginal fit.

Authors:  J R Holmes; S C Bayne; G A Holland; W D Sulik
Journal:  J Prosthet Dent       Date:  1989-10       Impact factor: 3.426

3.  Clinical fit of all-ceramic three-unit fixed partial dentures, generated with three different CAD/CAM systems.

Authors:  Sven Reich; Manfred Wichmann; Emeka Nkenke; Peter Proeschel
Journal:  Eur J Oral Sci       Date:  2005-04       Impact factor: 2.612

4.  Evaluation of the marginal fit of three margin designs of resin composite crowns using CAD/CAM.

Authors:  Effrosyni A Tsitrou; Simon E Northeast; Richard van Noort
Journal:  J Dent       Date:  2006-06-15       Impact factor: 4.379

5.  From blue to white: new high-strength material for Cerec--IPS e.max CAD LT.

Authors:  K Wiedhahn
Journal:  Int J Comput Dent       Date:  2007-01       Impact factor: 1.883

6.  In vitro evaluation of the "replica technique" in the measurement of the fit of Procera crowns.

Authors:  Habib Y Rahme; Georges E Tehini; Salim M Adib; Albert S Ardo; Khaldoun T Rifai
Journal:  J Contemp Dent Pract       Date:  2008-02-01

7.  Five-year clinical results of zirconia frameworks for posterior fixed partial dentures.

Authors:  Irena Sailer; Aurel Fehér; Frank Filser; Ludwig J Gauckler; Heinz Lüthy; Christoph Hans Franz Hämmerle
Journal:  Int J Prosthodont       Date:  2007 Jul-Aug       Impact factor: 1.681

8.  Marginal adaptation of castable ceramic crowns.

Authors:  J D Weaver; G H Johnson; D J Bales
Journal:  J Prosthet Dent       Date:  1991-12       Impact factor: 3.426

9.  Anterior crowns and gingival health.

Authors:  C Janenko; R J Smales
Journal:  Aust Dent J       Date:  1979-08       Impact factor: 2.291

10.  The fit of gold inlays and three ceramic inlay systems. A clinical and in vitro study.

Authors:  M Molin; S Karlsson
Journal:  Acta Odontol Scand       Date:  1993-08       Impact factor: 2.331

View more
  12 in total

1.  Influence of conventional and digital intraoral impressions on the fit of CAD/CAM-fabricated all-ceramic crowns.

Authors:  S Berrendero; M P Salido; A Valverde; A Ferreiroa; G Pradíes
Journal:  Clin Oral Investig       Date:  2016-01-23       Impact factor: 3.573

2.  The clinical accuracy of single crowns exclusively fabricated by digital workflow--the comparison of two systems.

Authors:  Petya K Brawek; Stefan Wolfart; Lutz Endres; Armin Kirsten; Sven Reich
Journal:  Clin Oral Investig       Date:  2013-01-31       Impact factor: 3.573

3.  Fitting accuracy of zirconia single crowns produced via digital and conventional impressions-a clinical comparative study.

Authors:  Matthias Rödiger; Arthur Heinitz; Ralf Bürgers; Sven Rinke
Journal:  Clin Oral Investig       Date:  2016-07-28       Impact factor: 3.573

4.  Accuracy of single-tooth restorations based on intraoral digital and conventional impressions in patients.

Authors:  Moritz Boeddinghaus; Eva Sabina Breloer; Peter Rehmann; Bernd Wöstmann
Journal:  Clin Oral Investig       Date:  2015-02-20       Impact factor: 3.573

5.  Chair-side generated posterior lithium disilicate crowns after 4 years.

Authors:  Sven Reich; Oliver Schierz
Journal:  Clin Oral Investig       Date:  2012-11-08       Impact factor: 3.573

6.  Comparison of marginal adaptation and internal fit of monolithic lithium disilicate crowns produced by 4 different CAD/CAM systems.

Authors:  Brunna Mota Ferrairo; Fernanda Furtado Piras; Feranda Ferruzzi Lima; Heitor Marques Honório; Marco Antonio Hungaro Duarte; Ana Flávia Sanches Borges; José Henrique Rubo
Journal:  Clin Oral Investig       Date:  2020-08-11       Impact factor: 3.573

7.  Effect of Die Spacer Thickness on the Fracture Resistance of CAD/CAM Lithium Disilicate Veneers on Maxillary First Premolars.

Authors:  Sherine Mohamed Farag; Mona Mohamed Ghoneim; Rania Reda Afifi
Journal:  Clin Cosmet Investig Dent       Date:  2021-06-08

8.  Accuracy and precision of polyurethane dental arch models fabricated using a three-dimensional subtractive rapid prototyping method with an intraoral scanning technique.

Authors:  Jae-Hong Kim; Ki-Baek Kim; Woong-Chul Kim; Ji-Hwan Kim; Hae-Young Kim
Journal:  Korean J Orthod       Date:  2014-03-19       Impact factor: 1.372

9.  Clinical gap changes after porcelain firing cycles of zirconia fixed dentures.

Authors:  Bugurman Burcu Bugurman; Sebnem Begum Turker
Journal:  J Adv Prosthodont       Date:  2014-06-24       Impact factor: 1.904

10.  Effect of the Crystallization Process on the Marginal and Internal Gaps of Lithium Disilicate CAD/CAM Crowns.

Authors:  Jae-Hong Kim; Seunghan Oh; Soo-Hyuk Uhm
Journal:  Biomed Res Int       Date:  2016-03-31       Impact factor: 3.411

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.