Literature DB >> 1403860

Effects of cement, cement space, marginal design, seating aid materials, and seating force on crown cementation.

C J Wang1, P L Millstein, D Nathanson.   

Abstract

An evaluation of the effects of a die spacer, the seating force, the marginal design, seating aid materials, and the cement type during cementation was conducted. Two stainless steel dies were used: one with a 1 mm shoulder and the other with a shoulder and a 65-degree bevel. Ten stone dies were produced from each metal die and half were painted with four layers of die spacer. The crowns were waxed on the dies and cast in a nonprecious alloy, and the seating of crowns was measured with a micrometer before and after cementation. Comparisons were made between zinc phosphate and glass ionomer cements under two seating forces of 5 and 30 lb using an orangewood stick or E-Z-bite seating aid. ANOVA and the Newman-Keuls test revealed that the use of a die spacer, a heavier force of 30 lb, and glass ionomer cement significantly improved crown seating. The beveled preparation led to superior crown seating when the heavier force or glass ionomer cement was used. The orangewood stick and bite device had a similar effect on crown seating.

Entities:  

Mesh:

Substances:

Year:  1992        PMID: 1403860     DOI: 10.1016/0022-3913(92)90583-v

Source DB:  PubMed          Journal:  J Prosthet Dent        ISSN: 0022-3913            Impact factor:   3.426


  14 in total

1.  Conventional and contemporary luting cements: an overview.

Authors:  Komal Ladha; Mahesh Verma
Journal:  J Indian Prosthodont Soc       Date:  2010-12-12

2.  Evaluation of the Luting Cement Space for Provisional Restoration by using Various Coats of Die Spacer Materials-An Invitro Study.

Authors:  Sandeep Chiramana; Krishna Chaitanya Siddineni; Ravi Rakesh Dev Jyothula; Phani Krishna Gade; Deepthi Bhupathi; Sudheer Kondaka; Zakir Hussain; Geetha Bhavani Paluri
Journal:  J Clin Diagn Res       Date:  2014-09-20

Review 3.  Tooth preparation for full-coverage restorations-a literature review.

Authors:  Anke Podhorsky; Peter Rehmann; Bernd Wöstmann
Journal:  Clin Oral Investig       Date:  2015-03-07       Impact factor: 3.573

4.  Dental Wings CAD/CAM system precision: an internal and marginal fit sperimental analisys.

Authors:  G Sannino; F Gloria; R Schiavetti; L Ottria; A Barlattani
Journal:  Oral Implantol (Rome)       Date:  2010-04-20

5.  An In Vitro Evaluation of the Microleakage under Complete Metal Crowns Using Three Adhesive Luting Cements.

Authors:  Sudhir Bhandari; Meena Aras; Vidya Chitre
Journal:  J Indian Prosthodont Soc       Date:  2011-11-01

6.  Measurement of cement thickness under lithium disilicate crowns using an impression material technique.

Authors:  Sven Reich; Sophia Uhlen; Stephan Gozdowski; Ulrich Lohbauer
Journal:  Clin Oral Investig       Date:  2010-05-12       Impact factor: 3.573

7.  Effect of seating forces on cement-ceramic adhesion in microtensile bond tests.

Authors:  Susana María Salazar Marocho; Mutlu Ozcan; Regina Amaral; Luiz Felipe Valandro; Marco Antonio Bottino
Journal:  Clin Oral Investig       Date:  2012-01-13       Impact factor: 3.573

8.  Effects of Finger Pressure Applied By Dentists during Cementation of All-Ceramic Crowns.

Authors:  Mustafa Zortuk; Pınar Bolpaca; Kerem Kilic; Eylem Ozdemir; Suleyman Aguloglu
Journal:  Eur J Dent       Date:  2010-10

9.  Evaluation of marginal fit of two all-ceramic copings with two finish lines.

Authors:  Gulce Subasi; Nilgun Ozturk; Ozgur Inan; Nalan Bozogullari
Journal:  Eur J Dent       Date:  2012-04

10.  In vitro evaluation of the effect of core thickness and fabrication stages on the marginal accuracy of an all-ceramic system.

Authors:  F Farid; H Hajimiragha; R Jelodar; A S Mostafavi; H Nokhbatolfoghahaie
Journal:  J Dent (Tehran)       Date:  2012-09-30
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.