Literature DB >> 32783095

Comparison of marginal adaptation and internal fit of monolithic lithium disilicate crowns produced by 4 different CAD/CAM systems.

Brunna Mota Ferrairo1, Fernanda Furtado Piras2, Feranda Ferruzzi Lima3,4, Heitor Marques Honório5, Marco Antonio Hungaro Duarte6, Ana Flávia Sanches Borges6, José Henrique Rubo7.   

Abstract

OBJECTIVES: To evaluate the marginal adaptation and internal space of crowns produced by 4 CAD/CAM systems using microcomputed tomography (μCT) and replica technique (RT).
MATERIALS AND METHODS: Monolithic lithium disilicate crowns were milled (Ceramill, Cerec, EDG, and Zirkonzahn) (n = 10). The cement film obtained with low viscosity silicone was scanned by the μCT system and captured by a stereomicroscope, according to RT. Two-way ANOVA followed by Tukey's test were used for statistical analysis (α = 0.05). A uniformity index (UI) was idealized to describe the distribution of crowns' internal space and submitted to the Kruskal-Wallis and Tukey's test (α = 0.05). The correlation between μCT and RT was performed by Pearson's Correlation Coeficient (α = 0.05).
RESULTS: Marginal adaptation and internal space were statistically significant different between the experimental groups for the μCT and RT (p < 0.05). The medians of the 4 systems tested were within clinically acceptable range and the mean (± SD) highest marginal discrepancy was recorded in the Ceramill group at 133.0 ± 71.5 μm (μCT) and 90.6 ± 38.5 μm (RT). For internal fit, the UI disclosed a better distribution of the internal space for the Zirkonzahn group (p < 0.001). There was a strong correlation between the methods (p = 0.01 and r = 0.69). CLINICAL RELEVANCE: Because of the variability of the CAD/CAM systems available, evaluating their accuracy is of clinical interest. The 4 systems are capable to produce restorations adaptated within clinically appropriate levels. The μCT and RT are efficient adaptation methodologies.

Entities:  

Keywords:  CAD/CAM systems; Internal fit; Marginal adaptation; Microcomputed tomography; Monolithic lithium disilicate ceramic; Replica technique

Mesh:

Substances:

Year:  2020        PMID: 32783095     DOI: 10.1007/s00784-020-03511-1

Source DB:  PubMed          Journal:  Clin Oral Investig        ISSN: 1432-6981            Impact factor:   3.573


  45 in total

1.  Evaluation of the marginal accuracy of different all-ceramic crown systems after simulation in the artificial mouth.

Authors:  S M Beschnidt; J R Strub
Journal:  J Oral Rehabil       Date:  1999-07       Impact factor: 3.837

Review 2.  Periodontal tissue responses after insertion of artificial crowns and fixed partial dentures.

Authors:  K L Knoernschild; S D Campbell
Journal:  J Prosthet Dent       Date:  2000-11       Impact factor: 3.426

3.  The effect of film thickness and surface texture on the resistance of cemented extracoronal restorations to lateral fatigue loading.

Authors:  H W Wiskott; U C Belser; S S Scherrer
Journal:  Int J Prosthodont       Date:  1999 May-Jun       Impact factor: 1.681

Review 4.  A review of dental CAD/CAM: current status and future perspectives from 20 years of experience.

Authors:  Takashi Miyazaki; Yasuhiro Hotta; Jun Kunii; Soichi Kuriyama; Yukimichi Tamaki
Journal:  Dent Mater J       Date:  2009-01       Impact factor: 2.102

5.  Effects of cement thickness and bonding on the failure loads of CAD/CAM ceramic crowns: multi-physics FEA modeling and monotonic testing.

Authors:  Liliana G May; J Robert Kelly; Marco A Bottino; Thomas Hill
Journal:  Dent Mater       Date:  2012-05-15       Impact factor: 5.304

6.  Influence of resin cement polymerization shrinkage on stresses in porcelain crowns.

Authors:  Liliana G May; J Robert Kelly
Journal:  Dent Mater       Date:  2013-08-22       Impact factor: 5.304

Review 7.  A systematic review of CAD/CAM fit restoration evaluations.

Authors:  P Boitelle; B Mawussi; L Tapie; O Fromentin
Journal:  J Oral Rehabil       Date:  2014-06-21       Impact factor: 3.837

8.  Shear bond strength of porcelain to a new millable alloy and a conventional castable alloy.

Authors:  Du-Hyeong Lee; Beom-Jun Lee; Sung-Hun Kim; Kyu-Bok Lee
Journal:  J Prosthet Dent       Date:  2015-02-11       Impact factor: 3.426

9.  Influence of cavity preparation design on fracture resistance of posterior Leucite-reinforced ceramic restorations.

Authors:  Carlos Jose Soares; Luis Roberto Marcondes Martins; Rodrigo Borges Fonseca; Lourenco Correr-Sobrinho; Alfredo Julio Fernandes Neto
Journal:  J Prosthet Dent       Date:  2006-06       Impact factor: 3.426

10.  Comparison of the bond strength of laser-sintered and cast base metal dental alloys to porcelain.

Authors:  Tolga Akova; Yurdanur Ucar; Alper Tukay; Mehmet Cudi Balkaya; William A Brantley
Journal:  Dent Mater       Date:  2008-04-15       Impact factor: 5.304