Literature DB >> 23371756

The clinical accuracy of single crowns exclusively fabricated by digital workflow--the comparison of two systems.

Petya K Brawek1, Stefan Wolfart, Lutz Endres, Armin Kirsten, Sven Reich.   

Abstract

OBJECTIVES: The purpose of the study was to compare the accuracy of crowns exclusively fabricated by the digital workflow of two systems. The null hypothesis stated was: Both systems do not differ with respect to marginal and internal accuracy.
MATERIALS AND METHODS: In 14 patients, 13 molars and 1 premolar were prepared. Each preparation was scanned intraorally with two different digital impression systems, Lava COS and Cerec AC. On the basis of these data, Lava DVS crowns [DVS] and Vita Rapid Layering Technique crowns [RLT] were fabricated, respectively. Both systems contained of a zirconia framework and a digitally fabricated silicate ceramic veneering. The marginal and internal fit of the crowns was documented by a replica technique. The replicas were examined under microscope with a magnification of ×200. The Wilcoxon signed rank test was applied in order to test if the values of the two systems showed significant differences at p ≤ 0.05.
RESULTS: The results were as follows in micrometers (±standard deviation): at the marginal gap, 51 (±38) for [DVS] and 83 (±51) for [RLT]; mid-axial, 130 (±56) for [DVS] and 128 (±66) for [RLT]; axio-occlusal, 178 (±55) for [DVS] and 230 (±71) for [RLT]; and centro-occlusal, 181 (±41) for [DVS] and 297 (±76) for [RLT]. According to the Wilcoxon signed rank test, the results differed significantly at the marginal, axio-occlusal, and centro-occlusal gaps.
CONCLUSIONS: The null hypothesis had to be rejected. CLINICAL RELEVANCE: The exclusively digital workflow on the basis of intraoral digital impressions delivered clinically satisfying results for single crowns with both systems.

Entities:  

Mesh:

Year:  2013        PMID: 23371756     DOI: 10.1007/s00784-013-0923-5

Source DB:  PubMed          Journal:  Clin Oral Investig        ISSN: 1432-6981            Impact factor:   3.573


  29 in total

Review 1.  Current state of development and perspectives of machine-based production methods for dental restorations.

Authors:  A Mehl; R Hickel
Journal:  Int J Comput Dent       Date:  1999-01       Impact factor: 1.883

2.  Dental CAD/CAM technologies: the optical impression (I).

Authors:  J Pfeiffer
Journal:  Int J Comput Dent       Date:  1998-09       Impact factor: 1.883

3.  Clinical evaluation of all-ceramic crowns fabricated from intraoral digital impressions based on the principle of active wavefront sampling.

Authors:  Andreas Syrek; Gunnar Reich; Dieter Ranftl; Christoph Klein; Barbara Cerny; Jutta Brodesser
Journal:  J Dent       Date:  2010-04-08       Impact factor: 4.379

4.  An innovative method for evaluation of the 3-D internal fit of CAD/CAM crowns fabricated after direct optical versus indirect laser scan digitizing.

Authors:  Ralph G Luthardt; Gido Bornemann; Susanne Lemelson; Michael H Walter; Alfons Hüls
Journal:  Int J Prosthodont       Date:  2004 Nov-Dec       Impact factor: 1.681

5.  Five-year clinical results of zirconia frameworks for posterior fixed partial dentures.

Authors:  Irena Sailer; Aurel Fehér; Frank Filser; Ludwig J Gauckler; Heinz Lüthy; Christoph Hans Franz Hämmerle
Journal:  Int J Prosthodont       Date:  2007 Jul-Aug       Impact factor: 1.681

6.  Accuracy testing of a new intraoral 3D camera.

Authors:  A Mehl; A Ender; W Mörmann; T Attin
Journal:  Int J Comput Dent       Date:  2009       Impact factor: 1.883

7.  A new triple-scan protocol for 3D fit assessment of dental restorations.

Authors:  Stefan Holst; Matthias Karl; Manfred Wichmann; Ragai-Edward T Matta
Journal:  Quintessence Int       Date:  2011-09       Impact factor: 1.677

8.  Three-dimensional fit of CAD/CAM-made zirconia copings.

Authors:  Ovidiu Moldovan; Ralph G Luthardt; Nicoleta Corcodel; Heike Rudolph
Journal:  Dent Mater       Date:  2011-10-07       Impact factor: 5.304

9.  The fit of gold inlays and three ceramic inlay systems. A clinical and in vitro study.

Authors:  M Molin; S Karlsson
Journal:  Acta Odontol Scand       Date:  1993-08       Impact factor: 2.331

10.  Measurement of cement thickness under lithium disilicate crowns using an impression material technique.

Authors:  Sven Reich; Sophia Uhlen; Stephan Gozdowski; Ulrich Lohbauer
Journal:  Clin Oral Investig       Date:  2010-05-12       Impact factor: 3.573

View more
  29 in total

1.  Clinical evaluation comparing the fit of all-ceramic crowns obtained from silicone and digital intraoral impressions.

Authors:  Cristina Zarauz; Arelhys Valverde; Francisco Martinez-Rus; Bassam Hassan; Guillermo Pradies
Journal:  Clin Oral Investig       Date:  2015-09-12       Impact factor: 3.573

2.  Influence of conventional and digital intraoral impressions on the fit of CAD/CAM-fabricated all-ceramic crowns.

Authors:  S Berrendero; M P Salido; A Valverde; A Ferreiroa; G Pradíes
Journal:  Clin Oral Investig       Date:  2016-01-23       Impact factor: 3.573

3.  Effect of Fabrication Technique on the Marginal Discrepancy and Resistance of Lithium Disilicate Crowns: An In Vitro Study.

Authors:  Ramtin Sadid-Zadeh; Rui Li; Lorin M Miller; Michael Simon
Journal:  J Prosthodont       Date:  2019-01-22       Impact factor: 2.752

4.  Evaluation of the Marginal Fit of CAD/CAM Crowns Fabricated Using Two Different Chairside CAD/CAM Systems on Preparations of Varying Quality.

Authors:  Walter Renne; Bethany Wolf; Raymond Kessler; Karen McPherson; Anthony S Mennito
Journal:  J Esthet Restor Dent       Date:  2015-07-14       Impact factor: 2.843

5.  Fitting accuracy of zirconia single crowns produced via digital and conventional impressions-a clinical comparative study.

Authors:  Matthias Rödiger; Arthur Heinitz; Ralf Bürgers; Sven Rinke
Journal:  Clin Oral Investig       Date:  2016-07-28       Impact factor: 3.573

6.  Trueness of four different milling procedures used in dental CAD/CAM systems.

Authors:  Corinna Kirsch; Andreas Ender; Thomas Attin; Albert Mehl
Journal:  Clin Oral Investig       Date:  2016-07-28       Impact factor: 3.573

7.  In vitro assessment of the accuracy of digital impressions prepared using a single system for full-arch restorations on implants.

Authors:  Leonardo Ciocca; Roberto Meneghello; Carlo Monaco; Gianpaolo Savio; Lorenzo Scheda; Maria Rosaria Gatto; Paolo Baldissara
Journal:  Int J Comput Assist Radiol Surg       Date:  2018-03-02       Impact factor: 2.924

8.  Evaluation of fit and efficiency of CAD/CAM fabricated all-ceramic restorations based on direct and indirect digitalization: a double-blinded, randomized clinical trial.

Authors:  Danush Ahrberg; Hans Christoph Lauer; Martin Ahrberg; Paul Weigl
Journal:  Clin Oral Investig       Date:  2015-06-14       Impact factor: 3.573

9.  Accuracy of single-tooth restorations based on intraoral digital and conventional impressions in patients.

Authors:  Moritz Boeddinghaus; Eva Sabina Breloer; Peter Rehmann; Bernd Wöstmann
Journal:  Clin Oral Investig       Date:  2015-02-20       Impact factor: 3.573

10.  Comparison of digital and conventional impression techniques: evaluation of patients' perception, treatment comfort, effectiveness and clinical outcomes.

Authors:  Emir Yuzbasioglu; Hanefi Kurt; Rana Turunc; Halenur Bilir
Journal:  BMC Oral Health       Date:  2014-01-30       Impact factor: 2.757

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.