Literature DB >> 20460211

High-resolution versus high-sensitivity SPECT imaging with geometric blurring compensation for various parallel-hole collimation geometries.

Bin Zhang1, Gengsheng L Zeng.   

Abstract

Recent studies have shown that trading efficiency for improved resolution may be a good choice for small lesion detection, but utilizing collimator with high efficiency may be more favorable for cardiac single photon emission computed tomography (SPECT). This paper investigates the tradeoffs of geometric-blurring compensation for high-resolution (HR) and high-sensitivity (HS) SPECT imaging with various parallel-hole collimators in terms of noise reduction and resolution recovery. Five types of collimators were investigated and compared with a general all purpose collimator using computer simulations. It is shown that less noisy SPECT images can be achieved with unchanged spatial resolution using large collimator holes with blurring compensation. The optimal collimator hole found in the computer simulation is the one with a hole acceptance angle in the range from 6.3 degrees to 9.4 degrees. Phantom experiments with two cardiac-insert phantoms show that the resolution of the image obtained using the HS collimator can be successfully recovered by blurring compensation, and the image is less noisy compared to the one obtained using the HR collimator.

Entities:  

Mesh:

Year:  2010        PMID: 20460211      PMCID: PMC5292234          DOI: 10.1109/TITB.2010.2050145

Source DB:  PubMed          Journal:  IEEE Trans Inf Technol Biomed        ISSN: 1089-7771


  17 in total

1.  Unmatched projector/backprojector pairs in an iterative reconstruction algorithm.

Authors:  G L Zeng; G T Gullberg
Journal:  IEEE Trans Med Imaging       Date:  2000-05       Impact factor: 10.048

2.  Noniterative compensation for the distance-dependent detector response and photon attenuation in SPECT imaging.

Authors:  S J Glick; B C Penney; M A King; C L Byrne
Journal:  IEEE Trans Med Imaging       Date:  1994       Impact factor: 10.048

3.  Practical tradeoffs between noise, quantitation, and number of iterations for maximum likelihood-based reconstructions.

Authors:  J S Liow; S C Strother
Journal:  IEEE Trans Med Imaging       Date:  1991       Impact factor: 10.048

4.  A method for obtaining an approximate Wiener filter.

Authors:  M T Madsen
Journal:  Med Phys       Date:  1990 Jan-Feb       Impact factor: 4.071

5.  The geometric transfer function for cone and fan beam collimators.

Authors:  B M Tsui; G T Gullberg
Journal:  Phys Med Biol       Date:  1990-01       Impact factor: 3.609

6.  Influence of OSEM, elliptical orbits and background activity on SPECT 3D resolution recovery.

Authors:  T S Pan; D S Luo; V Kohli; M A King
Journal:  Phys Med Biol       Date:  1997-12       Impact factor: 3.609

7.  Compensation of spatial system response in SPECT with conjugate gradient reconstruction technique.

Authors:  A R Formiconi; A Pupi; A Passeri
Journal:  Phys Med Biol       Date:  1989-01       Impact factor: 3.609

8.  Distance-weighted backprojection: a SPECT reconstruction technique.

Authors:  D J Nowak; R L Eisner; W A Fajman
Journal:  Radiology       Date:  1986-05       Impact factor: 11.105

9.  Impact of Mismatched Detector-Blur Models on Ga SPECT Tumor Detection.

Authors:  H C Gifford; M A King
Journal:  IEEE Nucl Sci Symp Conf Rec (1997)       Date:  2007

10.  Application of distance-dependent resolution compensation and post-reconstruction filtering for myocardial SPECT.

Authors:  B F Hutton; Y H Lau
Journal:  Phys Med Biol       Date:  1998-06       Impact factor: 3.609

View more
  4 in total

1.  Segmented slant hole collimator for stationary cardiac SPECT: Monte Carlo simulations.

Authors:  Yanfei Mao; Zhicong Yu; Gengsheng L Zeng
Journal:  Med Phys       Date:  2015-09       Impact factor: 4.071

2.  Joint optimization of collimator and reconstruction parameters in SPECT imaging for lesion quantification.

Authors:  Sarah J McQuaid; Sudeepti Southekal; Marie Foley Kijewski; Stephen C Moore
Journal:  Phys Med Biol       Date:  2011-11-07       Impact factor: 3.609

3.  Collimator optimization and collimator-detector response compensation in myocardial perfusion SPECT using the ideal observer with and without model mismatch and an anthropomorphic model observer.

Authors:  Michael Ghaly; Jonathan M Links; Eric C Frey
Journal:  Phys Med Biol       Date:  2016-02-19       Impact factor: 3.609

4.  Impact of iterative reconstruction with resolution recovery in myocardial perfusion SPECT: phantom and clinical studies.

Authors:  Koichi Okuda; Kenichi Nakajima; Hiroto Yoneyama; Takayuki Shibutani; Masahisa Onoguchi; Shinro Matsuo; Mitsumasa Hashimoto; Seigo Kinuya
Journal:  Sci Rep       Date:  2019-12-23       Impact factor: 4.379

  4 in total