Application of distance-dependent resolution compensation and post-reconstruction filtering for myocardial SPECT.

B F Hutton1, Y H Lau.   

Abstract

Compensation for distance-dependent resolution can be directly incorporated in maximum likelihood reconstruction. Our objective was to examine the effectiveness of this compensation using either the standard expectation maximization (EM) algorithm or an accelerated algorithm based on use of ordered subsets (OSEM). We also investigated the application of post-reconstruction filtering in combination with resolution compensation. Using the MCAT phantom, projections were simulated for 360 degrees data, including attenuation and distance-dependent resolution. Projection data were reconstructed using conventional EM and OSEM with subset size 2 and 4, with/without 3D compensation for detector response (CDR). Also post-reconstruction filtering (PRF) was performed using a 3D Butterworth filter of order 5 with various cutoff frequencies (0.2-1.2 cycles cm(-1)). Image quality and reconstruction accuracy were improved when CDR was included. Image noise was lower with CDR for a given iteration number. PRF with cutoff frequency greater than 0.6 cycles cm(-1) improved noise with no reduction in recovery coefficient for myocardium but the effect was less when CDR was incorporated in the reconstruction. CDR alone provided better results than use of PRF without CDR. Results suggest that using CDR without PRF, and stopping at a small number of iterations, may provide sufficiently good results for myocardial SPECT. Similar behaviour was demonstrated for OSEM.

Entities:  

Mesh:

Year:  1998        PMID: 9651033     DOI: 10.1088/0031-9155/43/6/022

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  10 in total

1.  Proposal for the standardisation of multi-centre trials in nuclear medicine imaging: prerequisites for a European 123I-FP-CIT SPECT database.

Authors:  John Caddell Dickson; Livia Tossici-Bolt; Terez Sera; Robin de Nijs; Jan Booij; Maria Claudia Bagnara; Anita Seese; Pierre Malick Koulibaly; Umit Ozgur Akdemir; Cathrine Jonsson; Michel Koole; Maria Raith; Markus Nowak Lonsdale; Jean George; Felicia Zito; Klaus Tatsch
Journal:  Eur J Nucl Med Mol Imaging       Date:  2012-01       Impact factor: 9.236

2.  Clinical results of a novel wide beam reconstruction method for shortening scan time of Tc-99m cardiac SPECT perfusion studies.

Authors:  Salvador Borges-Neto; Robert A Pagnanelli; Linda K Shaw; Emily Honeycutt; Shuli C Shwartz; George L Adams; Ralph Edward Coleman
Journal:  J Nucl Cardiol       Date:  2007-07       Impact factor: 5.952

3.  Correction of partial volume effects in myocardial SPECT.

Authors:  B F Hutton; A Osiecki
Journal:  J Nucl Cardiol       Date:  1998 Jul-Aug       Impact factor: 5.952

Review 4.  Absolute quantification in SPECT.

Authors:  Philipp Ritt; Hans Vija; Joachim Hornegger; Torsten Kuwert
Journal:  Eur J Nucl Med Mol Imaging       Date:  2011-04-12       Impact factor: 9.236

5.  Gated SPECT assessment of left ventricular function is sensitive to small patient motions and to low rates of triggering errors: a comparison with equilibrium radionuclide angiography.

Authors:  Wassila Djaballah; Marc A Muller; Anne C Bertrand; Pierre Y Marie; Bernard Chalon; Karim Djaballah; Pierre Olivier; Andreï Codreanu; Gilles Karcher; Alain Bertrand
Journal:  J Nucl Cardiol       Date:  2005 Jan-Feb       Impact factor: 5.952

6.  High-resolution versus high-sensitivity SPECT imaging with geometric blurring compensation for various parallel-hole collimation geometries.

Authors:  Bin Zhang; Gengsheng L Zeng
Journal:  IEEE Trans Inf Technol Biomed       Date:  2010-05-10

7.  Absolute quantitation of myocardial blood flow with (201)Tl and dynamic SPECT in canine: optimisation and validation of kinetic modelling.

Authors:  Hidehiro Iida; Stefan Eberl; Kyeong-Min Kim; Yoshikazu Tamura; Yukihiko Ono; Mayumi Nakazawa; Antti Sohlberg; Tsutomu Zeniya; Takuya Hayashi; Hiroshi Watabe
Journal:  Eur J Nucl Med Mol Imaging       Date:  2008-01-15       Impact factor: 9.236

8.  Improved quantification for local regions of interest in preclinical PET imaging.

Authors:  J Cal-González; S C Moore; M-A Park; J L Herraiz; J J Vaquero; M Desco; J M Udias
Journal:  Phys Med Biol       Date:  2015-09-03       Impact factor: 3.609

9.  A new reconstruction strategy for image improvement in pinhole SPECT.

Authors:  Tsutomu Zeniya; Hiroshi Watabe; Toshiyuki Aoi; Kyeong Min Kim; Noboru Teramoto; Takuya Hayashi; Antti Sohlberg; Hiroyuki Kudo; Hidehiro Iida
Journal:  Eur J Nucl Med Mol Imaging       Date:  2004-03-17       Impact factor: 9.236

10.  Investigation of Collimator Influential Parameter on SPECT Image Quality: a Monte Carlo Study.

Authors:  Sh Banari Bahnamiri
Journal:  J Biomed Phys Eng       Date:  2015-03-04
  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.