Literature DB >> 3485803

Distance-weighted backprojection: a SPECT reconstruction technique.

D J Nowak, R L Eisner, W A Fajman.   

Abstract

A method of reconstruction of single-photon emission computed tomographic (SPECT) images--distance-weighted filtered backprojection--is described. The quality of SPECT images using the standard filtered backprojection algorithm for data obtained from 360 degrees acquisitions is limited by the loss of spatial resolution with distance, and the attenuation and scatter inherent in the planar images used for reconstruction. In contrast to the standard techniques in which a reconstructed pixel receives equal contributions from 180 degrees opposed views, distance--weighted filtered backprojection applies a variable weighting factor to the data such that the pixel receives greater weight from the closest planar views. Data derived from hot and cold spot phantoms as well as from various clinical studies show better spatial and contrast resolution with this new technique compared with the conventional 360 degrees algorithm.

Mesh:

Year:  1986        PMID: 3485803     DOI: 10.1148/radiology.159.2.3485803

Source DB:  PubMed          Journal:  Radiology        ISSN: 0033-8419            Impact factor:   11.105


  5 in total

1.  Three-dimensional display of myocardial perfusion: detection of ischemic lesions using a new image subtraction method.

Authors:  P P Ferretti; G Borasi; D Salvo; D Serafini; A Versari
Journal:  Eur J Nucl Med       Date:  1990

2.  Improved image quality with elliptical orbits and distance-weighted backprojection SPECT reconstruction.

Authors:  R L Eisner; W A Fajman; D J Nowak; R I Pettigrew
Journal:  Ann Nucl Med       Date:  1988-11       Impact factor: 2.668

3.  Effects of non-linear flow and spatial orientation on technetium-99m hexamethylpropylene amine oxime single-photon emission tomography.

Authors:  S J Stapleton; C B Caldwell; L E Ehrlich; C L Leonhardt; S E Black; M J Yaffe
Journal:  Eur J Nucl Med       Date:  1995-09

4.  High-resolution versus high-sensitivity SPECT imaging with geometric blurring compensation for various parallel-hole collimation geometries.

Authors:  Bin Zhang; Gengsheng L Zeng
Journal:  IEEE Trans Inf Technol Biomed       Date:  2010-05-10

5.  Responsivity of the Striatal Dopamine System to Methylphenidate-A Within-Subject I-123-β-CIT-SPECT Study in Male Children and Adolescents With Attention-Deficit/Hyperactivity Disorder.

Authors:  Hans-Christoph Aster; Marcel Romanos; Susanne Walitza; Manfred Gerlach; Andreas Mühlberger; Albert Rizzo; Marta Andreatta; Natalie Hasenauer; Philipp E Hartrampf; Kai Nerlich; Christoph Reiners; Reinhard Lorenz; Andreas K Buck; Lorenz Deserno
Journal:  Front Psychiatry       Date:  2022-04-14       Impact factor: 5.435

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.