Literature DB >> 2304971

The geometric transfer function for cone and fan beam collimators.

B M Tsui1, G T Gullberg.   

Abstract

Geometric response functions are derived for both cone and fan beam collimators for the scintillation camera. The formulation is based on an effective response function which is determined by the geometric response of a single hole. The technique provides an accurate description of the spatial resolution by characterising the complete geometric response function which includes the effects of the shape and orientation of the collimator holes. The theoretical formulation was used to design a fan beam collimator for SPECT imaging and was shown to agree well with the experimental results.

Mesh:

Year:  1990        PMID: 2304971     DOI: 10.1088/0031-9155/35/1/008

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  10 in total

1.  Advances in SPECT camera software and hardware: currently available and new on the horizon.

Authors:  E Gordon DePuey
Journal:  J Nucl Cardiol       Date:  2012-06       Impact factor: 5.952

2.  Physical assessment of the GE/CGR Neurocam and comparison with a single rotating gamma-camera.

Authors:  K Kouris; P H Jarritt; D C Costa; P J Ell
Journal:  Eur J Nucl Med       Date:  1992

Review 3.  Advances in technical aspects of myocardial perfusion SPECT imaging.

Authors:  Piotr J Slomka; James A Patton; Daniel S Berman; Guido Germano
Journal:  J Nucl Cardiol       Date:  2009-02-26       Impact factor: 5.952

4.  Integration of SimSET photon history generator in GATE for efficient Monte Carlo simulations of pinhole SPECT.

Authors:  Chia-Lin Chen; Yuchuan Wang; Jason J S Lee; Benjamin M W Tsui
Journal:  Med Phys       Date:  2008-07       Impact factor: 4.071

Review 5.  Single Photon Emission Computed Tomography (SPECT) Myocardial Perfusion Imaging Guidelines: Instrumentation, Acquisition, Processing, and Interpretation.

Authors:  Sharmila Dorbala; Karthik Ananthasubramaniam; Ian S Armstrong; Panithaya Chareonthaitawee; E Gordon DePuey; Andrew J Einstein; Robert J Gropler; Thomas A Holly; John J Mahmarian; Mi-Ae Park; Donna M Polk; Raymond Russell; Piotr J Slomka; Randall C Thompson; R Glenn Wells
Journal:  J Nucl Cardiol       Date:  2018-10       Impact factor: 5.952

6.  High-resolution versus high-sensitivity SPECT imaging with geometric blurring compensation for various parallel-hole collimation geometries.

Authors:  Bin Zhang; Gengsheng L Zeng
Journal:  IEEE Trans Inf Technol Biomed       Date:  2010-05-10

7.  Development and validation of a Monte Carlo simulation tool for multi-pinhole SPECT.

Authors:  Greta S P Mok; Yong Du; Yuchuan Wang; Eric C Frey; Benjamin M W Tsui
Journal:  Mol Imaging Biol       Date:  2009-09-25       Impact factor: 3.488

8.  Ordered subset expectation maximization and wide beam reconstruction "half-time" gated myocardial perfusion SPECT functional imaging: a comparison to "full-time" filtered backprojection.

Authors:  E Gordon DePuey; Ramesh Gadiraju; John Clark; Linda Thompson; Frank Anstett; Shuli C Shwartz
Journal:  J Nucl Cardiol       Date:  2008-04-24       Impact factor: 5.952

9.  The geometric response function for convergent slit-slat collimators.

Authors:  Yusheng Li; James Oldendick; Caesar E Ordonez; Wei Chang
Journal:  Phys Med Biol       Date:  2009-02-13       Impact factor: 3.609

10.  Fast quantitative reconstruction with focusing collimators for liver SPECT.

Authors:  Martijn M A Dietze; Sandra van der Velden; Marnix G E H Lam; Max A Viergever; Hugo W A M de Jong
Journal:  EJNMMI Phys       Date:  2018-12-04
  10 in total