Literature DB >> 20439787

Prosthesis-patient mismatch predicts structural valve degeneration in bioprosthetic heart valves.

Willem Flameng1, Marie-Christine Herregods, Monique Vercalsteren, Paul Herijgers, Kris Bogaerts, Bart Meuris.   

Abstract

BACKGROUND: Prosthesis-patient mismatch (P-PtM) after aortic valve replacement results in disturbed valve performance associated with increased pressure gradients. However, it is unknown whether this can be related to future structural valve deterioration (SVD) of the bioprosthesis. METHODS AND
RESULTS: In 564 patients (mean age, 74+/-5 years) receiving an aortic valve bioprosthesis, clinical follow-up (median, 6.1 years; maximum, 16.4 years) was analyzed including echocardiography. SVD was diagnosed in 40 patients (7%) as substantially increased stenosis (n=24) or regurgitation (n=16) of the operated valve over time. When patients with P-PtM (effective orifice area index <0.85 cm(2)/m(2); n=285) developed SVD, it was preferentially of the stenosis type, whereas when patients without P-PtM (n=279) developed SVD, the majority was of the incompetence type (P<0.05). Multivariable analysis including patient- and valve-related variables revealed that P-PtM and label size </=21 were independent predictors of SVD (P=0.04 and P=0.02, respectively). A nonparametric Turnbull estimate analysis showed that SVD is virtually nonexistent for up to 9 years in patients without P-PtM. Thereafter, SVD starts to occur and is mainly of the incompetence-type SVD (79% of cases). In patients with P-PtM, SVD starts to occur after 2 to 3 years after implantation and is mainly of the stenosis-type SVD (81% of cases).
CONCLUSIONS: These data suggest that stenosis-type SVD is an early, P-PtM-related, and thus preventable phenomenon. Incompetence-type SVD is a time-dependent, nonspecific wear damage to bioprosthetic valves, which is not related to P-PtM.

Entities:  

Mesh:

Year:  2010        PMID: 20439787     DOI: 10.1161/CIRCULATIONAHA.109.901272

Source DB:  PubMed          Journal:  Circulation        ISSN: 0009-7322            Impact factor:   29.690


  37 in total

1.  Valvular disease: The private life of tissue valves.

Authors:  Magdi H Yacoub; Ismail El-Hamamsy
Journal:  Nat Rev Cardiol       Date:  2010-08       Impact factor: 32.419

2.  Aortic stenosis: An update.

Authors:  Sangeetha Nathaniel; Shreyas Saligram; Antony Leslie Innasimuthu
Journal:  World J Cardiol       Date:  2010-06-26

Review 3.  Valve durability after transcatheter aortic valve implantation.

Authors:  Akash Kataruka; Catherine M Otto
Journal:  J Thorac Dis       Date:  2018-11       Impact factor: 2.895

4.  Long-term durability of bioprosthetic aortic valves: implications from 12,569 implants.

Authors:  Douglas R Johnston; Edward G Soltesz; Nakul Vakil; Jeevanantham Rajeswaran; Eric E Roselli; Joseph F Sabik; Nicholas G Smedira; Lars G Svensson; Bruce W Lytle; Eugene H Blackstone
Journal:  Ann Thorac Surg       Date:  2015-02-04       Impact factor: 4.330

Review 5.  Prosthesis-patient mismatch: an update.

Authors:  Jean G Dumesnil; Philippe Pibarot
Journal:  Curr Cardiol Rep       Date:  2011-06       Impact factor: 2.931

6.  The choice of heart valve prosthesis for aortic valve replacement in the young: about choices and consequences.

Authors:  Thierry Bove
Journal:  Ann Transl Med       Date:  2018-05

Review 7.  Durability of prostheses for transcatheter aortic valve implantation.

Authors:  Mani Arsalan; Thomas Walther
Journal:  Nat Rev Cardiol       Date:  2016-04-07       Impact factor: 32.419

8.  Transapical sutureless aortic valve implantation under magnetic resonance imaging guidance: Acute and short-term results.

Authors:  Keith A Horvath; Dumitru Mazilu; Junfeng Cai; Bogdan Kindzelski; Ming Li
Journal:  J Thorac Cardiovasc Surg       Date:  2014-11-01       Impact factor: 5.209

Review 9.  Update on aortic valve prosthesis-patient mismatch in Japan.

Authors:  Yoshimasa Sakamoto; Kazuhiro Hashimoto
Journal:  Gen Thorac Cardiovasc Surg       Date:  2013-04-13

Review 10.  Prosthesis-Patient Mismatch After Aortic Valve Replacement.

Authors:  Abdellaziz Dahou; Haïfa Mahjoub; Philippe Pibarot
Journal:  Curr Treat Options Cardiovasc Med       Date:  2016-11
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.