PURPOSE: To assess in vitro the three-dimensional mean velocity field and the extent and degree of turbulence intensity (TI) in different prosthetic heart valves using a generalization of phase-contrast MRI (PC-MRI). MATERIALS AND METHODS: Four 27-mm aortic valves (Björk-Shiley Monostrut tilting-disc, St. Jude Medical Standard bileaflet, Medtronic Mosaic stented and Freestyle stentless porcine valve) were tested under steady inflow conditions in a Plexiglas phantom. Three-dimensional PC-MRI data were acquired to measure the mean velocity field and the turbulent kinetic energy (TKE), a direction-independent measure of TI. RESULTS: Velocity and TI estimates could be obtained up- and downstream of the valves, except where metallic structure in the valves caused signal void. Distinct differences in the location, extent, and peak values of velocity and TI were observed between the valves tested. The maximum values of TKE varied between the different valves: tilting disc, 100 J/m(3); bileaflet, 115 J/m(3); stented, 200 J/m(3); stentless, 145 J/m(3). CONCLUSION: The TI downstream from a prosthetic heart valve is dependent on the specific valve design. Generalized PC-MRI can be used to quantify velocity and TI downstream from prosthetic heart valves, which may allow assessment of these aspects of prosthetic valvular function in postoperative patients. Copyright 2010 Wiley-Liss, Inc.
PURPOSE: To assess in vitro the three-dimensional mean velocity field and the extent and degree of turbulence intensity (TI) in different prosthetic heart valves using a generalization of phase-contrast MRI (PC-MRI). MATERIALS AND METHODS: Four 27-mm aortic valves (Björk-Shiley Monostrut tilting-disc, St. Jude Medical Standard bileaflet, Medtronic Mosaic stented and Freestyle stentless porcine valve) were tested under steady inflow conditions in a Plexiglas phantom. Three-dimensional PC-MRI data were acquired to measure the mean velocity field and the turbulent kinetic energy (TKE), a direction-independent measure of TI. RESULTS: Velocity and TI estimates could be obtained up- and downstream of the valves, except where metallic structure in the valves caused signal void. Distinct differences in the location, extent, and peak values of velocity and TI were observed between the valves tested. The maximum values of TKE varied between the different valves: tilting disc, 100 J/m(3); bileaflet, 115 J/m(3); stented, 200 J/m(3); stentless, 145 J/m(3). CONCLUSION: The TI downstream from a prosthetic heart valve is dependent on the specific valve design. Generalized PC-MRI can be used to quantify velocity and TI downstream from prosthetic heart valves, which may allow assessment of these aspects of prosthetic valvular function in postoperative patients. Copyright 2010 Wiley-Liss, Inc.
Authors: Edouard Semaan; Michael Markl; S Chris Malaisrie; Alex Barker; Bradley Allen; Patrick McCarthy; James C Carr; Jeremy D Collins Journal: Eur J Cardiothorac Surg Date: 2013-12-06 Impact factor: 4.191
Authors: Alex J Barker; Pim van Ooij; Krishna Bandi; Julio Garcia; Mazen Albaghdadi; Patrick McCarthy; Robert O Bonow; James Carr; Jeremy Collins; S Chris Malaisrie; Michael Markl Journal: Magn Reson Med Date: 2013-10-02 Impact factor: 4.668
Authors: Eric J Keller; S Chris Malaisrie; Jane Kruse; Patrick M McCarthy; James C Carr; Michael Markl; Alex J Barker; Jeremy D Collins Journal: Interact Cardiovasc Thorac Surg Date: 2016-05-30
Authors: Daniel Giese; Kilian Weiss; Bettina Baeßler; Navid Madershahian; Yeong-Hoon Choi; David Maintz; Alexander C Bunck Journal: MAGMA Date: 2017-09-18 Impact factor: 2.310
Authors: Thomas Wehrum; Felix Guenther; Alexander Fuchs; Florian Schuchardt; Anja Hennemuth; Andreas Harloff Journal: Int J Cardiovasc Imaging Date: 2018-01-11 Impact factor: 2.357
Authors: M Markl; S Schnell; C Wu; E Bollache; K Jarvis; A J Barker; J D Robinson; C K Rigsby Journal: Clin Radiol Date: 2016-03-02 Impact factor: 2.350
Authors: Jeremy D Collins; Edouard Semaan; Alex Barker; Patrick M McCarthy; James C Carr; Michael Markl; S Chris Malaisrie Journal: Ann Thorac Surg Date: 2015-07-23 Impact factor: 4.330