Abstract

The laboratory diagnosis of syphilis is based primarily upon serologic findings. Historically, serologic testing for syphilis has relied on assays such as rapid plasma reagin, fluorescent treponemal antibody absorption, Treponema pallidum particle agglutination (TP-PA), and more recently, enzyme immunoassay (EIA). In this study, we evaluated the performance of a novel multiplex flow immunoassay (BioPlex 2200 Syphilis; Bio-Rad Laboratories, Hercules, CA) for the detection of antitreponemal IgG- and IgM-class antibodies. Serum specimens (n = 1,008) submitted for routine treponema-specific antibody testing by syphilis IgM and IgG EIA (Trep-Chek; Phoenix-Biotech, Mississauga, Ontario, Canada) were also analyzed by the BioPlex Syphilis multiplex assay. Specimens showing discordant results were repeat tested, with further discrepancies being arbitrated by TP-PA. Compared directly to the results of EIA, the BioPlex IgG assay demonstrated 98.7% (77/78) sensitivity and 99.4% (916/930) specificity. Compared to the Trep-Chek IgM EIA, the BioPlex IgM assay showed 80% (4/5) sensitivity and 97.9% (652/666) specificity. These results indicate that the BioPlex Syphilis multiplex assay shows similar serological agreement with EIA while allowing for a fully automated random-access platform that provides faster (1.7 h for 100 samples versus 4.5 h by EIA) and higher-throughput (800 samples per 9 h versus 200 samples by EIA) analysis of the syphilis serologic response.

Entities:  

Mesh:

Substances:

Year:  2010        PMID: 20427627      PMCID: PMC2884415          DOI: 10.1128/CVI.00086-10

Source DB:  PubMed          Journal:  Clin Vaccine Immunol        ISSN: 1556-679X


  19 in total

1.  The pattern of immunological responses at various stages of syphilis.

Authors:  R Shannon; S D Booth
Journal:  Br J Vener Dis       Date:  1977-10

2.  IgM class antitreponemal antibody in treated and untreated syphilis.

Authors:  P O'Neill; C S Nicol
Journal:  Br J Vener Dis       Date:  1972-12

3.  Evaluation of the Captia enzyme immunoassays for detection of immunoglobulins G and M to Treponema pallidum in syphilis.

Authors:  J C Lefevre; M A Bertrand; R Bauriaud
Journal:  J Clin Microbiol       Date:  1990-08       Impact factor: 5.948

4.  Comparative evaluation of nine different enzyme-linked immunosorbent assays for determination of antibodies against Treponema pallidum in patients with primary syphilis.

Authors:  B L Schmidt; M Edjlalipour; A Luger
Journal:  J Clin Microbiol       Date:  2000-03       Impact factor: 5.948

5.  Evaluation of an enzyme immunoassay for IgM antibodies to Treponema pallidum in syphilis in man.

Authors:  F Müller; M Moskophidis
Journal:  Br J Vener Dis       Date:  1984-10

6.  Evaluation of three multiplex flow immunoassays compared to an enzyme immunoassay for the detection and differentiation of IgG class antibodies to herpes simplex virus types 1 and 2.

Authors:  M J Binnicker; D J Jespersen; J A Harring
Journal:  Clin Vaccine Immunol       Date:  2009-12-09

Review 7.  Laboratory diagnosis and interpretation of tests for syphilis.

Authors:  S A Larsen; B M Steiner; A H Rudolph
Journal:  Clin Microbiol Rev       Date:  1995-01       Impact factor: 26.132

8.  Evaluation of a Treponema pallidum-specific IgM enzyme immunoassay and Treponema pallidum western blot antibody detection in the diagnosis of maternal and congenital syphilis.

Authors:  Sarah A Rawstron; Swati Mehta; Kenneth Bromberg
Journal:  Sex Transm Dis       Date:  2004-02       Impact factor: 2.830

9.  Enzyme-linked immunosorbent assay for detection of immunoglobulin M antibody against the Reiter treponeme flagellum in syphilis.

Authors:  N S Pedersen; C S Petersen; N H Axelsen
Journal:  J Clin Microbiol       Date:  1982-10       Impact factor: 5.948

Review 10.  Cytometric bead array: a multiplexed assay platform with applications in various areas of biology.

Authors:  Edward Morgan; Rudi Varro; Homero Sepulveda; Julia A Ember; John Apgar; Jerry Wilson; Larry Lowe; Roy Chen; Lalita Shivraj; Anissa Agadir; Roberto Campos; David Ernst; Amitabh Gaur
Journal:  Clin Immunol       Date:  2004-03       Impact factor: 3.969

View more
  17 in total

1.  Direct comparison of the traditional and reverse syphilis screening algorithms in a population with a low prevalence of syphilis.

Authors:  Matthew J Binnicker; Deborah J Jespersen; Leonard O Rollins
Journal:  J Clin Microbiol       Date:  2011-11-16       Impact factor: 5.948

Review 2.  The endemic treponematoses.

Authors:  Lorenzo Giacani; Sheila A Lukehart
Journal:  Clin Microbiol Rev       Date:  2014-01       Impact factor: 26.132

3.  Identification of false-positive syphilis antibody results using a semiquantitative algorithm.

Authors:  Belinda Yen-Lieberman; Juliet Daniel; Cathy Means; Joan Waletzky; Thomas M Daly
Journal:  Clin Vaccine Immunol       Date:  2011-04-20

Review 4.  Recent trends in the serologic diagnosis of syphilis.

Authors:  Muhammad G Morshed; Ameeta E Singh
Journal:  Clin Vaccine Immunol       Date:  2014-11-26

5.  Clinical Performance of the BioPlex 2200 Syphilis Total & RPR Assay at a Tertiary Medical Center with a High Rate of Syphilis.

Authors:  Merih T Tesfazghi; Neil W Anderson; Ann M Gronowski; Melanie L Yarbrough
Journal:  J Clin Microbiol       Date:  2019-01-02       Impact factor: 5.948

6.  Treponema-specific tests for serodiagnosis of syphilis: comparative evaluation of seven assays.

Authors:  M J Binnicker; D J Jespersen; L O Rollins
Journal:  J Clin Microbiol       Date:  2011-02-23       Impact factor: 5.948

7.  Evaluation of the Lumipulse G TP-N Chemiluminescent Immunoassay as a Syphilis Screening Test.

Authors:  Daniel A Ortiz; Michael J Loeffelholz
Journal:  J Clin Microbiol       Date:  2017-09-06       Impact factor: 5.948

8.  Multiplex detection of IgM and IgG class antibodies to Toxoplasma gondii, rubella virus, and cytomegalovirus using a novel multiplex flow immunoassay.

Authors:  M J Binnicker; D J Jespersen; J A Harring
Journal:  Clin Vaccine Immunol       Date:  2010-09-22

9.  Evaluation of the BioPlex 2200 syphilis system as a first-line method of reverse-sequence screening for syphilis diagnosis.

Authors:  Antonella Marangoni; Paola Nardini; Claudio Foschi; Alessandra Moroni; Antonietta D'Antuono; Letizia Bacchi Reggiani; Roberto Cevenini
Journal:  Clin Vaccine Immunol       Date:  2013-05-22

10.  Performance of the BioPlex 2200 flow immunoassay in critical cases of serodiagnosis of toxoplasmosis.

Authors:  Nicolas Guigue; Jean Menotti; Samia Hamane; Francis Derouin; Yves Jean-François Garin
Journal:  Clin Vaccine Immunol       Date:  2014-01-29
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.