Literature DB >> 15047203

Cytometric bead array: a multiplexed assay platform with applications in various areas of biology.

Edward Morgan1, Rudi Varro, Homero Sepulveda, Julia A Ember, John Apgar, Jerry Wilson, Larry Lowe, Roy Chen, Lalita Shivraj, Anissa Agadir, Roberto Campos, David Ernst, Amitabh Gaur.   

Abstract

The introduction of flow cytometric bead-based technology has added a new approach for investigators to simultaneously measure multiple analytes in biological and environmental samples. This new technology allows for (1) evaluation of multiple analytes in a single sample; (2) utilization of minimal sample volumes to glean data; (3) reproducibility and results comparative with previous experiments; (4) direct comparison with existing assays; and (5) a more rapid evaluation of multiple samples in a single platform. The cytometric bead array (CBA) system enables simultaneous measurement of multiple analytes in sample volumes too small for traditional immunoassays. Results have been presented for the analysis of a variety of human cytokines. In addition, the technology allows for the design and creation of assays to measure a variety of analytes including inflammatory mediators, chemokines, immunoglobulin isotypes, intracellular signaling molecules, apoptotic mediators, adhesion molecules, and antibodies. New initiatives put forward by the Human Genome Project and the FDA require the development and use of assays for the rapid simultaneous quantitation of multiple analytes. The CBA technology provides the ability to quantify multiple proteins within a given sample, with precision and consistency.

Entities:  

Mesh:

Substances:

Year:  2004        PMID: 15047203     DOI: 10.1016/j.clim.2003.11.017

Source DB:  PubMed          Journal:  Clin Immunol        ISSN: 1521-6616            Impact factor:   3.969


  145 in total

Review 1.  New technologies for autoimmune disease monitoring.

Authors:  Holden T Maecker; Garry P Nolan; Charles G Fathman
Journal:  Curr Opin Endocrinol Diabetes Obes       Date:  2010-08       Impact factor: 3.243

2.  Serum IL-33 levels are associated with liver damage in patients with chronic hepatitis B.

Authors:  Juan Wang; Yanjun Cai; Huifan Ji; Junyan Feng; Desalegn Admassu Ayana; Junqi Niu; Yanfang Jiang
Journal:  J Interferon Cytokine Res       Date:  2012-02-03       Impact factor: 2.607

3.  Cytokine profile in patients undergoing minimally invasive surgery with balanced anesthesia.

Authors:  José Eduardo B Orosz; Mariana G Braz; Márjorie A Golim; Márcio Antônio A Barreira; Denise Fecchio; Leandro G Braz; José Reinaldo C Braz
Journal:  Inflammation       Date:  2012-12       Impact factor: 4.092

4.  Calcitonin gene-related peptide contributes to peripheral nerve injury-induced mechanical hypersensitivity through CCL5 and p38 pathways.

Authors:  Jennifer T Malon; Ling Cao
Journal:  J Neuroimmunol       Date:  2016-05-06       Impact factor: 3.478

5.  Same-day detection of Escherichia coli O157:H7 from spinach by using electrochemiluminescent and cytometric bead array biosensors.

Authors:  Kelly M Leach; Joyce M Stroot; Daniel V Lim
Journal:  Appl Environ Microbiol       Date:  2010-10-29       Impact factor: 4.792

6.  Evaluation of three multiplex flow immunoassays compared to an enzyme immunoassay for the detection and differentiation of IgG class antibodies to herpes simplex virus types 1 and 2.

Authors:  M J Binnicker; D J Jespersen; J A Harring
Journal:  Clin Vaccine Immunol       Date:  2009-12-09

7.  [Cytokine determination from vitreous samples in retinal vascular diseases].

Authors:  M Pfister; F H Koch; J Cinatl; F Rothweiler; R Schubert; P Singh; H Ackermann; M J Koss
Journal:  Ophthalmologe       Date:  2013-08       Impact factor: 1.059

8.  Combination testing for antibodies in the diagnosis of coeliac disease: comparison of multiplex immunoassay and ELISA methods.

Authors:  S Rashtak; M W Ettore; H A Homburger; J A Murray
Journal:  Aliment Pharmacol Ther       Date:  2008-09-15       Impact factor: 8.171

9.  High-mobility group box 1 protein in CSF of patients with subarachnoid hemorrhage.

Authors:  Takashi Nakahara; Ryosuke Tsuruta; Tadashi Kaneko; Susumu Yamashita; Motoki Fujita; Shunji Kasaoka; Teruto Hashiguchi; Michiyasu Suzuki; Ikuro Maruyama; Tsuyoshi Maekawa
Journal:  Neurocrit Care       Date:  2009-09-24       Impact factor: 3.210

Review 10.  Antibody-based protein multiplex platforms: technical and operational challenges.

Authors:  Allison A Ellington; Iftikhar J Kullo; Kent R Bailey; George G Klee
Journal:  Clin Chem       Date:  2009-12-03       Impact factor: 8.327

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.