Functionally interpretable local coordinate systems for the upper extremity using inertial & magnetic measurement systems.

W H K de Vries1, H E J Veeger, A G Cutti, C Baten, F C T van der Helm.   

Abstract

BACKGROUND: Inertial Magnetic Measurement Systems (IMMS) are becoming increasingly popular by allowing for measurements outside the motion laboratory. The latest models enable long term, accurate measurement of segment motion in terms of joint angles, if initial segment orientations can accurately be determined. The standard procedure for definition of segmental orientation is based on the measurement of positions of bony landmarks (BLM). However, IMMS do not deliver position information, so an alternative method to establish IMMS based, anatomically understandable segment orientations is proposed.
METHODS: For five subjects, IMMS recordings were collected in a standard anatomical position for definition of static axes, and during a series of standardized motions for the estimation of kinematic axes of rotation. For all axes, the intra- and inter-individual dispersion was estimated. Subsequently, local coordinate systems (LCS) were constructed on the basis of the combination of IMMS axes with the lowest dispersion and compared with BLM based LCS.
FINDINGS: The repeatability of the method appeared to be high; for every segment at least two axes could be determined with a dispersion of at most 3.8 degrees. Comparison of IMMS based with BLM based LCS yielded compatible results for the thorax, but less compatible results for the humerus, forearm and hand, where differences in orientation rose to 17.2 degrees.
INTERPRETATION: Although different from the 'gold standard' BLM based LCS, IMMS based LCS can be constructed repeatable, enabling the estimation of segment orientations outside the laboratory.
CONCLUSIONS: A procedure for the definition of local reference frames using IMMS is proposed. 2010 Elsevier Ltd. All rights reserved.

Entities:  

Mesh:

Year:  2010        PMID: 20382385     DOI: 10.1016/j.jbiomech.2010.03.007

Source DB:  PubMed          Journal:  J Biomech        ISSN: 0021-9290            Impact factor:   2.712


  26 in total

1.  Quadrupedal Locomotion-Respiration Entrainment and Metabolic Economy in Cross-Country Skiers.

Authors:  Kevin Boldt; Anthony Killick; Walter Herzog
Journal:  J Appl Biomech       Date:  2015-08-06       Impact factor: 1.833

2.  Intra-protocol repeatability and inter-protocol agreement for the analysis of scapulo-humeral coordination.

Authors:  I Parel; A G Cutti; A Kraszewski; G Verni; H Hillstrom; A Kontaxis
Journal:  Med Biol Eng Comput       Date:  2013-10-18       Impact factor: 2.602

3.  Two linear regression models predicting cumulative dynamic L5/S1 joint moment during a range of lifting tasks based on static postures.

Authors:  Xu Xu; Chien-Chi Chang; Ming-Lun Lu
Journal:  Ergonomics       Date:  2012-07-17       Impact factor: 2.778

4.  Reliability and precision of 3D wireless measurement of scapular kinematics.

Authors:  Josien C van den Noort; Suzanne H Wiertsema; Karin M C Hekman; Casper P Schönhuth; Joost Dekker; Jaap Harlaar
Journal:  Med Biol Eng Comput       Date:  2014-09-06       Impact factor: 2.602

5.  Shoulder biomechanics and the success of translational research.

Authors:  Andrea Giovanni Cutti; Edward K Chadwick
Journal:  Med Biol Eng Comput       Date:  2014-03       Impact factor: 2.602

6.  Principal components of wrist circumduction from electromagnetic surgical tracking.

Authors:  Brian J Rasquinha; Michael J Rainbow; Michelle L Zec; David R Pichora; Randy E Ellis
Journal:  Int J Comput Assist Radiol Surg       Date:  2016-07-22       Impact factor: 2.924

7.  IMU-based sensor-to-segment multiple calibration for upper limb joint angle measurement-a proof of concept.

Authors:  Mahdi Zabat; Amina Ababou; Noureddine Ababou; Raphaël Dumas
Journal:  Med Biol Eng Comput       Date:  2019-08-30       Impact factor: 2.602

8.  Validation of Inertial Measurement Units for Upper Body Kinematics.

Authors:  Melissa M B Morrow; Bethany Lowndes; Emma Fortune; Kenton R Kaufman; M Susan Hallbeck
Journal:  J Appl Biomech       Date:  2017-06-26       Impact factor: 1.833

9.  Functional calibration does not improve the concurrent validity of magneto-inertial wearable sensor-based thorax and lumbar angle measurements when compared with retro-reflective motion capture.

Authors:  Daniel S Cottam; Amity C Campbell; Paul C Davey; Peter Kent; Bruce C Elliott; Jacqueline A Alderson
Journal:  Med Biol Eng Comput       Date:  2021-09-16       Impact factor: 2.602

10.  Accuracy and repeatability of an inertial measurement unit system for field-based occupational studies.

Authors:  Mark C Schall; Nathan B Fethke; Howard Chen; Sakiko Oyama; David I Douphrate
Journal:  Ergonomics       Date:  2015-10-07       Impact factor: 2.561

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.