IMU-based sensor-to-segment multiple calibration for upper limb joint angle measurement-a proof of concept.

Mahdi Zabat1, Amina Ababou2, Noureddine Ababou1, Raphaël Dumas3.   

Abstract

A lot of attention has been paid to wearable inertial sensors regarded as an alternative solution for outdoor human motion tracking. Relevant joint angles can only be calculated from anatomical orientations, but they are negatively impacted by soft tissue artifact (STA) defined as skin motion with respect to the underlying bone; the accuracy of measured joint angle during movement is affected by the ongoing misalignment of the sensor. In this work, a new sensor-to-segment calibration using inertial measurement units is proposed. Inspired by the multiple calibration for a cluster of skin markers, it consists in performing first multiple static postures of the upper limb in all anatomical planes. The movements that affect sensor alignment are identified then alignment differences between sensors and segment frames are calculated for each posture and linearly interpolated. Experimental measurements were carried out on a mechanical model and on a subject who performed different movements of right elbow and shoulder. Multiple calibration showed significant improvement in joint angle measurement on the mechanical model as well as on human joint angle comparing to those obtained from attached sensors after technical calibration. During shoulder internal-external rotation, the maximal error value decreased more than 50% after correction. Graphical abstract Elbow flexion-extension joint angle values obtained from IMUs are well-corrected after applying multiple calibration procedure. Though shoulder internal-external rotation joint angle is more affected by soft tissue artifact, multiple calibration procedure improves the angle values obtained from IMUs.

Entities:  

Keywords:  Calibration; IMU measurement; Joint angle; Posture; Soft tissue artifact

Mesh:

Year:  2019        PMID: 31471784     DOI: 10.1007/s11517-019-02033-7

Source DB:  PubMed          Journal:  Med Biol Eng Comput        ISSN: 0140-0118            Impact factor:   2.602


  35 in total

1.  A linear soft tissue artefact model for human movement analysis: proof of concept using in vivo data.

Authors:  Michael S Andersen; Michael Damsgaard; John Rasmussen; Dan K Ramsey; Daniel L Benoit
Journal:  Gait Posture       Date:  2012-01-04       Impact factor: 2.840

2.  Soft tissue artefact assessment in humeral axial rotation.

Authors:  Andrea Giovanni Cutti; Gabriele Paolini; Marco Troncossi; Angelo Cappello; Angelo Davalli
Journal:  Gait Posture       Date:  2005-04       Impact factor: 2.840

Review 3.  ISB recommendation on definitions of joint coordinate systems of various joints for the reporting of human joint motion--Part II: shoulder, elbow, wrist and hand.

Authors:  Ge Wu; Frans C T van der Helm; H E J DirkJan Veeger; Mohsen Makhsous; Peter Van Roy; Carolyn Anglin; Jochem Nagels; Andrew R Karduna; Kevin McQuade; Xuguang Wang; Frederick W Werner; Bryan Buchholz
Journal:  J Biomech       Date:  2005-05       Impact factor: 2.712

4.  Ambulatory measurement of arm orientation.

Authors:  H J Luinge; P H Veltink; C T M Baten
Journal:  J Biomech       Date:  2006-02-07       Impact factor: 2.712

5.  Joint kinematics estimate using wearable inertial and magnetic sensing modules.

Authors:  Pietro Picerno; Andrea Cereatti; Aurelio Cappozzo
Journal:  Gait Posture       Date:  2008-05-23       Impact factor: 2.840

6.  A model of the soft tissue artefact rigid component.

Authors:  V Camomilla; T Bonci; R Dumas; L Chèze; A Cappozzo
Journal:  J Biomech       Date:  2015-06-05       Impact factor: 2.712

7.  A novel functional calibration method for real-time elbow joint angles estimation with magnetic-inertial sensors.

Authors:  G Ligorio; D Zanotto; A M Sabatini; S K Agrawal
Journal:  J Biomech       Date:  2017-01-30       Impact factor: 2.712

8.  Alignment-Free, Self-Calibrating Elbow Angles Measurement Using Inertial Sensors.

Authors:  Philipp Muller; Marc-Andre Begin; Thomas Schauer; Thomas Seel
Journal:  IEEE J Biomed Health Inform       Date:  2016-12-14       Impact factor: 5.772

9.  Accuracy and repeatability of single-pose calibration of inertial measurement units for whole-body motion analysis.

Authors:  Xavier Robert-Lachaine; Hakim Mecheri; Christian Larue; André Plamondon
Journal:  Gait Posture       Date:  2017-03-01       Impact factor: 2.840

10.  An IMU-to-Body Alignment Method Applied to Human Gait Analysis.

Authors:  Laura Susana Vargas-Valencia; Arlindo Elias; Eduardo Rocon; Teodiano Bastos-Filho; Anselmo Frizera
Journal:  Sensors (Basel)       Date:  2016-12-10       Impact factor: 3.576

View more
  2 in total

1.  Portable, open-source solutions for estimating wrist position during reaching in people with stroke.

Authors:  Jeffrey Z Nie; James W Nie; Na-Teng Hung; R James Cotton; Marc W Slutzky
Journal:  Sci Rep       Date:  2021-11-18       Impact factor: 4.379

2.  Effects of Internal Fixation for Mid-Shaft Clavicle Fractures on Shoulder Kinematics During Humeral Elevations.

Authors:  Li-Wei Hung; Hsuan-Yu Lu; Chung-Hsun Chang; Tsan-Yang Chen; Ting-Ming Wang; Tung-Wu Lu
Journal:  Front Bioeng Biotechnol       Date:  2021-07-22
  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.