Literature DB >> 24136689

Intra-protocol repeatability and inter-protocol agreement for the analysis of scapulo-humeral coordination.

I Parel1, A G Cutti, A Kraszewski, G Verni, H Hillstrom, A Kontaxis.   

Abstract

Multi-center clinical trials incorporating shoulder kinematics are currently uncommon. The absence of repeatability and limits of agreement (LoA) studies between different centers employing different motion analysis protocols has led to a lack dataset compatibility. Therefore, the aim of this work was to determine the repeatability and LoA between two shoulder kinematic protocols. The first one uses a scapula tracker (ST), the International Society of Biomechanics anatomical frames and an optoelectronic measurement system, and the second uses a spine tracker, the INAIL Shoulder and Elbow Outpatient protocol (ISEO) and an inertial and magnetic measurement system. First within-protocol repeatability for each approach was assessed on a group of 23 healthy subjects and compared with the literature. Then, the between-protocol agreement was evaluated. The within-protocol repeatability was similar for the ST ([Formula: see text] = 2.35°, [Formula: see text] = 0.97°, SEM = 2.5°) and ISEO ([Formula: see text] = 2.24°, [Formula: see text] = 0.97°, SEM = 2.3°) protocols and comparable with data from published literature. The between-protocol agreement analysis showed comparable scapula medio-lateral rotation measurements for up to 120° of flexion-extension and up to 100° of scapula plane ab-adduction. Scapula protraction-retraction measurements were in agreement for a smaller range of humeral elevation. The results of this study suggest comparable repeatability for the ST and ISEO protocols and between-protocol agreement for two scapula rotations. Different thresholds for repeatability and LoA may be adapted to suit different clinical hypotheses.

Entities:  

Mesh:

Year:  2013        PMID: 24136689     DOI: 10.1007/s11517-013-1121-y

Source DB:  PubMed          Journal:  Med Biol Eng Comput        ISSN: 0140-0118            Impact factor:   2.602


  27 in total

1.  The position of the rotation center of the glenohumeral joint.

Authors:  H E Veeger
Journal:  J Biomech       Date:  2000-12       Impact factor: 2.712

Review 2.  Applying the right statistics: analyses of measurement studies.

Authors:  J M Bland; D G Altman
Journal:  Ultrasound Obstet Gynecol       Date:  2003-07       Impact factor: 7.299

3.  A new method for estimating joint parameters from motion data.

Authors:  Michael H Schwartz; Adam Rozumalski
Journal:  J Biomech       Date:  2005-01       Impact factor: 2.712

4.  Comparison between tripod and skin-fixed recording of scapular motion.

Authors:  Carel G M Meskers; Michiel A J van de Sande; Jurriaan H de Groot
Journal:  J Biomech       Date:  2006-04-11       Impact factor: 2.712

5.  Ambulatory measurement of shoulder and elbow kinematics through inertial and magnetic sensors.

Authors:  Andrea Giovanni Cutti; Andrea Giovanardi; Laura Rocchi; Angelo Davalli; Rinaldo Sacchetti
Journal:  Med Biol Eng Comput       Date:  2007-12-18       Impact factor: 2.602

6.  Reliability, repeatability and reproducibility: analysis of measurement errors in continuous variables.

Authors:  J W Bartlett; C Frost
Journal:  Ultrasound Obstet Gynecol       Date:  2008-04       Impact factor: 7.299

Review 7.  Alterations in shoulder kinematics and associated muscle activity in people with symptoms of shoulder impingement.

Authors:  P M Ludewig; T M Cook
Journal:  Phys Ther       Date:  2000-03

8.  Motion of the shoulder complex during multiplanar humeral elevation.

Authors:  Paula M Ludewig; Vandana Phadke; Jonathan P Braman; Daniel R Hassett; Cort J Cieminski; Robert F LaPrade
Journal:  J Bone Joint Surg Am       Date:  2009-02       Impact factor: 5.284

9.  Three-dimensional scapular kinematics and scapulohumeral rhythm in patients with glenohumeral osteoarthritis or frozen shoulder.

Authors:  Fouad Fayad; Agnès Roby-Brami; Chadi Yazbeck; Sylvain Hanneton; Marie-Martine Lefevre-Colau; Vincent Gautheron; Serge Poiraudeau; Michel Revel
Journal:  J Biomech       Date:  2007-10-18       Impact factor: 2.712

10.  Adaptation of scapula lateral rotation after reverse anatomy shoulder replacement.

Authors:  Andreas Kontaxis; Garth R Johnson
Journal:  Comput Methods Biomech Biomed Engin       Date:  2007-10-15       Impact factor: 1.763

View more
  9 in total

1.  Reliability and precision of 3D wireless measurement of scapular kinematics.

Authors:  Josien C van den Noort; Suzanne H Wiertsema; Karin M C Hekman; Casper P Schönhuth; Joost Dekker; Jaap Harlaar
Journal:  Med Biol Eng Comput       Date:  2014-09-06       Impact factor: 2.602

2.  Shoulder biomechanics and the success of translational research.

Authors:  Andrea Giovanni Cutti; Edward K Chadwick
Journal:  Med Biol Eng Comput       Date:  2014-03       Impact factor: 2.602

3.  The latissimus dorsi tendon functions as an external rotator after arthroscopic-assisted transfer for massive irreparable posterosuperior rotator cuff tears.

Authors:  Olimpio Galasso; Matteo Mantovani; Marco Muraccini; Antonella Berardi; Massimo De Benedetto; Nicola Orlando; Giorgio Gasparini; Roberto Castricini
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2019-12-06       Impact factor: 4.342

4.  Studying upper-limb kinematics using inertial sensors: a cross-sectional study.

Authors:  Cristina Roldán-Jiménez; Antonio I Cuesta-Vargas
Journal:  BMC Res Notes       Date:  2015-10-03

5.  Studying Upper-Limb Kinematics Using Inertial Sensors Embedded in Mobile Phones.

Authors:  Cristina Roldan-Jimenez; Antonio Cuesta-Vargas; Paul Bennett
Journal:  JMIR Rehabil Assist Technol       Date:  2015-05-20

6.  Development of a 3D workspace shoulder assessment tool incorporating electromyography and an inertial measurement unit-a preliminary study.

Authors:  Navid Aslani; Siamak Noroozi; Philip Davenport; Richard Hartley; Mihai Dupac; Philip Sewell
Journal:  Med Biol Eng Comput       Date:  2017-11-11       Impact factor: 2.602

7.  Evaluation of a novel portable three-dimensional scapular kinematics assessment system with inter and intraobserver reproducibility and normative data for healthy adults.

Authors:  Miguel Angel Ruiz Ibán; Andrea Paniagua Gonzalez; Marco Muraccini; Cristina Asenjo Gismero; Alessandro Varini; Antonella Berardi; Matteo Mantovani
Journal:  J Exp Orthop       Date:  2020-05-13

8.  The agreement and repeatability of measurements of ankle joint dorsiflexion and poplietal angle in healthy adolescents.

Authors:  Krzysztof Pietrzak; Izabela Miechowicz; Krzysztof Nowocień; Bartosz Kraszewski; Piotr Rzymski
Journal:  J Foot Ankle Res       Date:  2022-09-07       Impact factor: 3.050

9.  A survey of human shoulder functional kinematic representations.

Authors:  Rakesh Krishnan; Niclas Björsell; Elena M Gutierrez-Farewik; Christian Smith
Journal:  Med Biol Eng Comput       Date:  2018-10-26       Impact factor: 2.602

  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.