Literature DB >> 20376709

Constrained liner in neurologic or cognitively impaired patients undergoing primary THA.

Philippe Hernigou1, Paolo Filippini, Charles-Henri Flouzat-Lachaniette, Sobrinho Uirassu Batista, Alexandre Poignard.   

Abstract

BACKGROUND: THA performed in patients with cognitive deficits or neuromuscular diseases has been associated with a high postoperative dislocation rate. The constrained liner reportedly provides stability in patients with recurrent dislocation. However, achieving stability could be offset by early loosening when used in patients with neurologic diseases. QUESTIONS/PURPOSES: We therefore asked whether constrained liners had a higher risk of loosening when used in primary THA for patients with neurologic diseases.
METHODS: We retrospectively reviewed a 144 patients (164 hips) with neuromuscular disease who had a constrained polyethylene insert from 1999 to 2004 and compared them to another 120 patients (132 hips) with neuromuscular disease operated on immediately before this period (from 1994 to 1998) who had a conventional polyethylene insert.
RESULTS: Thirty-three (25%) of the 132 hips without a constrained liner were known to have had at least one dislocation and 21 had revision for recurrent dislocation. Ten other hips had revision for loosening of the cup. The survival rate was 82% at 5 years and 77% at 10 years with revision due to recurrent dislocation or loosening of the cup as the endpoint. With a constrained liner, at minimum 5-year followup (mean, 7 years; range, 5-10 years), the incidence of complications, particularly dislocation, was decreased (three dislocations among 164 hips; 2%), with one revision for recurrent dislocation and one revision for loosening.
CONCLUSIONS: This constrained acetabular component provides durable protection against dislocation without substantial increased loosening at midterm followup.

Entities:  

Mesh:

Substances:

Year:  2010        PMID: 20376709      PMCID: PMC2974891          DOI: 10.1007/s11999-010-1340-6

Source DB:  PubMed          Journal:  Clin Orthop Relat Res        ISSN: 0009-921X            Impact factor:   4.176


  40 in total

1.  Outcome and complications of constrained acetabular components.

Authors:  Cao Yang; Stuart B Goodman
Journal:  Orthopedics       Date:  2009-02       Impact factor: 1.390

2.  Radiological demarcation of cemented sockets in total hip replacement.

Authors:  J G DeLee; J Charnley
Journal:  Clin Orthop Relat Res       Date:  1976 Nov-Dec       Impact factor: 4.176

3.  "Modes of failure" of cemented stem-type femoral components: a radiographic analysis of loosening.

Authors:  T A Gruen; G M McNeice; H C Amstutz
Journal:  Clin Orthop Relat Res       Date:  1979-06       Impact factor: 4.176

4.  Preliminary report on the S-ROM constraining acetabular insert: a retrospective clinical experience.

Authors:  A V Lombardi; T H Mallory; T J Kraus; B K Vaughn
Journal:  Orthopedics       Date:  1991-03       Impact factor: 1.390

5.  Hip fractures and Parkinson's disease. A clinical review of 94 fractures treated surgically.

Authors:  R Turcotte; C Godin; R Duchesne; A Jodoin
Journal:  Clin Orthop Relat Res       Date:  1990-07       Impact factor: 4.176

6.  Classification and treatment of dislocations of total hip arthroplasty.

Authors:  L D Dorr; A W Wolf; R Chandler; J P Conaty
Journal:  Clin Orthop Relat Res       Date:  1983-03       Impact factor: 4.176

7.  Efficacy of abduction bracing in the management of total hip arthroplasty dislocation.

Authors:  Hargovind Dewal; Stephen L Maurer; Peter Tsai; Edward Su; Rudi Hiebert; Paul E Di Cesare
Journal:  J Arthroplasty       Date:  2004-09       Impact factor: 4.757

8.  Dislocations after total hip arthroplasty.

Authors:  R Y Woo; B F Morrey
Journal:  J Bone Joint Surg Am       Date:  1982-12       Impact factor: 5.284

9.  Dislocation after total hip arthroplasty. Treatment with an above-knee hip spica cast.

Authors:  J F Williams; M J Gottesman; T H Mallory
Journal:  Clin Orthop Relat Res       Date:  1982 Nov-Dec       Impact factor: 4.176

10.  Recurrent dislocation after total hip replacement. Treatment by fixing an additional sector to the acetabular component.

Authors:  S Olerud; G Karlström
Journal:  J Bone Joint Surg Br       Date:  1985-05
View more
  20 in total

1.  Is Parkinson's Disease Associated with Increased Mortality, Poorer Outcomes Scores, and Revision Risk After THA? Findings from the Swedish Hip Arthroplasty Register.

Authors:  Alex Leigh Wojtowicz; Maziar Mohaddes; Daniel Odin; Erik Bülow; Szilard Nemes; Peter Cnudde
Journal:  Clin Orthop Relat Res       Date:  2019-06       Impact factor: 4.176

2.  Bony impingement limits design-related increases in hip range of motion.

Authors:  Adam Bunn; Clifford W Colwell; Darryl D D'Lima
Journal:  Clin Orthop Relat Res       Date:  2012-02       Impact factor: 4.176

3.  Instability after total hip arthroplasty.

Authors:  Brian C Werner; Thomas E Brown
Journal:  World J Orthop       Date:  2012-08-18

Review 4.  Dual-mobility arthroplasty failure: a rationale review of causes and technical considerations for revision.

Authors:  Philippe Hernigou; Arnaud Dubory; Damien Potage; François Roubineau; Charles Henri Flouzat Lachaniette
Journal:  Int Orthop       Date:  2016-11-21       Impact factor: 3.075

5.  Dual-mobility implants prevent hip dislocation following hip revision in obese patients.

Authors:  Philippe Hernigou; Jean Charles Auregan; Damien Potage; François Roubineau; Charles Henri Flouzat Lachaniette; Arnaud Dubory
Journal:  Int Orthop       Date:  2016-10-20       Impact factor: 3.075

6.  High dislocation cumulative risk in THA versus hemiarthroplasty for fractures.

Authors:  Alexandre Poignard; Mohamed Bouhou; Olivier Pidet; Charles-Henri Flouzat-Lachaniette; Philippe Hernigou
Journal:  Clin Orthop Relat Res       Date:  2011-07-20       Impact factor: 4.176

7.  Acetabular liner with focal constraint to prevent dislocation after THA.

Authors:  Jacob T Munro; Mihai H Vioreanu; Bassam A Masri; Clive P Duncan
Journal:  Clin Orthop Relat Res       Date:  2013-12       Impact factor: 4.176

8.  Ceramic-on-ceramic bearing decreases the cumulative long-term risk of dislocation.

Authors:  Philippe Hernigou; Yasuhiro Homma; Olivier Pidet; Isaac Guissou; Jacques Hernigou
Journal:  Clin Orthop Relat Res       Date:  2013-12       Impact factor: 4.176

9.  Dual-mobility or Constrained Liners Are More Effective Than Preoperative Bariatric Surgery in Prevention of THA Dislocation.

Authors:  Philippe Hernigou; Matthieu Trousselier; François Roubineau; Charlie Bouthors; Charles Henri Flouzat Lachaniette
Journal:  Clin Orthop Relat Res       Date:  2016-10       Impact factor: 4.176

10.  The risk of dislocation after total hip arthroplasty for fractures is decreased with retentive cups.

Authors:  Philippe Hernigou; Louis Ratte; François Roubineau; Jacques Pariat; Guillaume Mirouse; Isaac Guissou; Jerome Allain; Charles Henri Flouzat Lachaniette
Journal:  Int Orthop       Date:  2013-05-12       Impact factor: 3.075

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.