Literature DB >> 20352289

Fast reduction of undersampling artifacts in radial MR angiography with 3D total variation on graphics hardware.

Florian Knoll1, Markus Unger, Clemens Diwoky, Christian Clason, Thomas Pock, Rudolf Stollberger.   

Abstract

OBJECTIVE: Subsampling of radially encoded MRI acquisitions in combination with sparsity promoting methods opened a door to significantly increased imaging speed, which is crucial for many important clinical applications. In particular, it has been shown recently that total variation (TV) regularization efficiently reduces undersampling artifacts. The drawback of the method is the long reconstruction time which makes it impossible to use in daily clinical practice, especially if the TV optimization problem has to be solved repeatedly to select a proper regularization parameter.
MATERIALS AND METHODS: The goal of this work was to show that for the case of MR Angiography, TV filtering can be performed as a post-processing step, in contrast to the common approach of integrating TV penalties in the image reconstruction process. With this approach, it is possible to use TV algorithms with data fidelity terms in image space, which can be implemented very efficiently on graphic processing units (GPUs). The combination of a special radial sampling trajectory and a full 3D formulation of the TV minimization problem is crucial for the effectiveness of the artifact elimination process. RESULTS AND
CONCLUSION: The computation times of GPU-TV show that interactive elimination of undersampling artifacts is possible even for large volume data sets, in particular allowing the interactive determination of the regularization parameter. Results from phantom measurements and in vivo angiography data sets show that 3D TV, together with the proposed sampling trajectory, leads to pronounced improvements in image quality. However, while artifact removal was very efficient for angiography data sets in this work, it cannot be expected that the proposed method of TV post-processing will work for arbitrary types of scans.

Entities:  

Mesh:

Year:  2010        PMID: 20352289      PMCID: PMC4011129          DOI: 10.1007/s10334-010-0207-x

Source DB:  PubMed          Journal:  MAGMA        ISSN: 0968-5243            Impact factor:   2.310


  13 in total

1.  Undersampled projection reconstruction applied to MR angiography.

Authors:  D C Peters; F R Korosec; T M Grist; W F Block; J E Holden; K K Vigen; C A Mistretta
Journal:  Magn Reson Med       Date:  2000-01       Impact factor: 4.668

2.  Unaliasing by fourier-encoding the overlaps using the temporal dimension (UNFOLD), applied to cardiac imaging and fMRI.

Authors:  B Madore; G H Glover; N J Pelc
Journal:  Magn Reson Med       Date:  1999-11       Impact factor: 4.668

3.  SENSE: sensitivity encoding for fast MRI.

Authors:  K P Pruessmann; M Weiger; M B Scheidegger; P Boesiger
Journal:  Magn Reson Med       Date:  1999-11       Impact factor: 4.668

4.  Generalized autocalibrating partially parallel acquisitions (GRAPPA).

Authors:  Mark A Griswold; Peter M Jakob; Robin M Heidemann; Mathias Nittka; Vladimir Jellus; Jianmin Wang; Berthold Kiefer; Axel Haase
Journal:  Magn Reson Med       Date:  2002-06       Impact factor: 4.668

5.  Time-resolved contrast-enhanced imaging with isotropic resolution and broad coverage using an undersampled 3D projection trajectory.

Authors:  Andrew V Barger; Walter F Block; Yuriy Toropov; Thomas M Grist; Charles A Mistretta
Journal:  Magn Reson Med       Date:  2002-08       Impact factor: 4.668

6.  k-t BLAST and k-t SENSE: dynamic MRI with high frame rate exploiting spatiotemporal correlations.

Authors:  Jeffrey Tsao; Peter Boesiger; Klaas P Pruessmann
Journal:  Magn Reson Med       Date:  2003-11       Impact factor: 4.668

7.  k-t BLAST reconstruction from non-Cartesian k-t space sampling.

Authors:  Michael S Hansen; Christof Baltes; Jeffrey Tsao; Sebastian Kozerke; Klaas P Pruessmann; Holger Eggers
Journal:  Magn Reson Med       Date:  2006-01       Impact factor: 4.668

8.  Highly constrained backprojection for time-resolved MRI.

Authors:  C A Mistretta; O Wieben; J Velikina; W Block; J Perry; Y Wu; K Johnson; Y Wu
Journal:  Magn Reson Med       Date:  2006-01       Impact factor: 4.668

9.  Undersampled radial MRI with multiple coils. Iterative image reconstruction using a total variation constraint.

Authors:  Kai Tobias Block; Martin Uecker; Jens Frahm
Journal:  Magn Reson Med       Date:  2007-06       Impact factor: 4.668

10.  Sparse MRI: The application of compressed sensing for rapid MR imaging.

Authors:  Michael Lustig; David Donoho; John M Pauly
Journal:  Magn Reson Med       Date:  2007-12       Impact factor: 4.668

View more
  8 in total

1.  Influence of temporal regularization and radial undersampling factor on compressed sensing reconstruction in dynamic contrast enhanced MRI of the breast.

Authors:  Sungheon G Kim; Li Feng; Robert Grimm; Melanie Freed; Kai Tobias Block; Daniel K Sodickson; Linda Moy; Ricardo Otazo
Journal:  J Magn Reson Imaging       Date:  2015-06-01       Impact factor: 4.813

2.  Compressed sensing reconstruction for whole-heart imaging with 3D radial trajectories: a graphics processing unit implementation.

Authors:  Seunghoon Nam; Mehmet Akçakaya; Tamer Basha; Christian Stehning; Warren J Manning; Vahid Tarokh; Reza Nezafat
Journal:  Magn Reson Med       Date:  2012-03-05       Impact factor: 4.668

3.  snapMRF: GPU-accelerated magnetic resonance fingerprinting dictionary generation and matching using extended phase graphs.

Authors:  Dong Wang; Jason Ostenson; David S Smith
Journal:  Magn Reson Imaging       Date:  2019-11-15       Impact factor: 2.546

4.  Second order total generalized variation (TGV) for MRI.

Authors:  Florian Knoll; Kristian Bredies; Thomas Pock; Rudolf Stollberger
Journal:  Magn Reson Med       Date:  2010-12-08       Impact factor: 4.668

5.  Single-breath-hold 3-D CINE imaging of the left ventricle using Cartesian sampling.

Authors:  Jens Wetzl; Michaela Schmidt; François Pontana; Benjamin Longère; Felix Lugauer; Andreas Maier; Joachim Hornegger; Christoph Forman
Journal:  MAGMA       Date:  2017-05-26       Impact factor: 2.310

6.  Three-dimensional late gadolinium enhancement imaging of the left atrium with a hybrid radial acquisition and compressed sensing.

Authors:  Ganesh Adluru; Liyong Chen; Seong-Eun Kim; Nathan Burgon; Eugene G Kholmovski; Nassir F Marrouche; Edward V R Dibella
Journal:  J Magn Reson Imaging       Date:  2011-10-03       Impact factor: 4.813

7.  More IMPATIENT: A Gridding-Accelerated Toeplitz-based Strategy for Non-Cartesian High-Resolution 3D MRI on GPUs.

Authors:  Jiading Gai; Nady Obeid; Joseph L Holtrop; Xiao-Long Wu; Fan Lam; Maojing Fu; Justin P Haldar; Wen-Mei W Hwu; Zhi-Pei Liang; Bradley P Sutton
Journal:  J Parallel Distrib Comput       Date:  2013-05-01       Impact factor: 3.734

8.  An augmented Lagrangian based compressed sensing reconstruction for non-Cartesian magnetic resonance imaging without gridding and regridding at every iteration.

Authors:  Mehmet Akçakaya; Seunghoon Nam; Tamer A Basha; Keigo Kawaji; Vahid Tarokh; Reza Nezafat
Journal:  PLoS One       Date:  2014-09-12       Impact factor: 3.240

  8 in total