Literature DB >> 12210938

Time-resolved contrast-enhanced imaging with isotropic resolution and broad coverage using an undersampled 3D projection trajectory.

Andrew V Barger1, Walter F Block, Yuriy Toropov, Thomas M Grist, Charles A Mistretta.   

Abstract

Time-resolved contrast-enhanced 3D MR angiography (MRA) methods have gained in popularity but are still limited by the tradeoff between spatial and temporal resolution. A method is presented that greatly reduces this tradeoff by employing undersampled 3D projection reconstruction trajectories. The variable density k-space sampling intrinsic to this sequence is combined with temporal k-space interpolation to provide time frames as short as 4 s. This time resolution reduces the need for exact contrast timing while also providing dynamic information. Spatial resolution is determined primarily by the projection readout resolution and is thus isotropic across the FOV, which is also isotropic. Although undersampling the outer regions of k-space introduces aliased energy into the image, which may compromise resolution, this is not a limiting factor in high-contrast applications such as MRA. Results from phantom and volunteer studies are presented demonstrating isotropic resolution, broad coverage with an isotropic field of view (FOV), minimal projection reconstruction artifacts, and temporal information. In one application, a single breath-hold exam covering the entire pulmonary vasculature generates high-resolution, isotropic imaging volumes depicting the bolus passage. Copyright 2002 Wiley-Liss, Inc.

Mesh:

Substances:

Year:  2002        PMID: 12210938     DOI: 10.1002/mrm.10212

Source DB:  PubMed          Journal:  Magn Reson Med        ISSN: 0740-3194            Impact factor:   4.668


  105 in total

1.  Reconstruction of dynamic image series from undersampled MRI data using data-driven model consistency condition (MOCCO).

Authors:  Julia V Velikina; Alexey A Samsonov
Journal:  Magn Reson Med       Date:  2014-11-14       Impact factor: 4.668

Review 2.  Neurovascular MRI with dynamic contrast-enhanced subtraction angiography.

Authors:  S C Coley; J M Wild; I D Wilkinson; P D Griffiths
Journal:  Neuroradiology       Date:  2003-09-20       Impact factor: 2.804

3.  Dynamic magnetic resonance imaging paragraph sign with radial scanning: a post-acquisition paragraph sign keyhole approach.

Authors:  R Lethmate; H Ratiney; F T A W Wajer; Y Crémillieux; D van Ormondt; D Graveron-Demilly
Journal:  MAGMA       Date:  2003-02       Impact factor: 2.310

4.  Meniscal calcifications: morphologic and quantitative evaluation by using 2D inversion-recovery ultrashort echo time and 3D ultrashort echo time 3.0-T MR imaging techniques--feasibility study.

Authors:  Patrick Omoumi; Won C Bae; Jiang Du; Eric Diaz; Sheronda Statum; Graeme M Bydder; Christine B Chung
Journal:  Radiology       Date:  2012-07       Impact factor: 11.105

5.  Trajectory Auto-Corrected image reconstruction.

Authors:  Julianna D Ianni; William A Grissom
Journal:  Magn Reson Med       Date:  2015-09-12       Impact factor: 4.668

6.  NonCartesian MR image reconstruction with integrated gradient nonlinearity correction.

Authors:  Shengzhen Tao; Joshua D Trzasko; Yunhong Shu; John Huston; Kevin M Johnson; Paul T Weavers; Erin M Gray; Matt A Bernstein
Journal:  Med Phys       Date:  2015-12       Impact factor: 4.071

7.  Four-dimensional phase contrast MRI with accelerated dual velocity encoding.

Authors:  Elizabeth J Nett; Kevin M Johnson; Alex Frydrychowicz; Alejandro Munoz Del Rio; Eric Schrauben; Christopher J Francois; Oliver Wieben
Journal:  J Magn Reson Imaging       Date:  2012-01-26       Impact factor: 4.813

8.  Volumetric late gadolinium-enhanced myocardial imaging with retrospective inversion time selection.

Authors:  Steve Kecskemeti; Kevin Johnson; Christopher J François; Mark L Schiebler; Orhan Unal
Journal:  J Magn Reson Imaging       Date:  2013-02-06       Impact factor: 4.813

9.  Reproducibility of cerebrospinal venous blood flow and vessel anatomy with the use of phase contrast-vastly undersampled isotropic projection reconstruction and contrast-enhanced MRA.

Authors:  E M Schrauben; K M Johnson; J Huston; A M Del Rio; S B Reeder; A Field; O Wieben
Journal:  AJNR Am J Neuroradiol       Date:  2013-11-28       Impact factor: 3.825

10.  Accelerated whole-heart coronary MRA using motion-corrected sensitivity encoding with three-dimensional projection reconstruction.

Authors:  Jianing Pang; Behzad Sharif; Reza Arsanjani; Xiaoming Bi; Zhaoyang Fan; Qi Yang; Kuncheng Li; Daniel S Berman; Debiao Li
Journal:  Magn Reson Med       Date:  2014-01-16       Impact factor: 4.668

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.