Literature DB >> 20222149

Effects of motion and b-matrix correction for high resolution DTI with short-axis PROPELLER-EPI.

Murat Aksoy1, Stefan Skare, Samantha Holdsworth, Roland Bammer.   

Abstract

Short-axis PROPELLER-EPI (SAP-EPI) has been proven to be very effective in providing high-resolution diffusion-weighted and diffusion tensor data. The self-navigation capabilities of SAP-EPI allow one to correct for motion, phase errors, and geometric distortion. However, in the presence of patient motion, the change in the effective diffusion- encoding direction (i.e. the b-matrix) between successive PROPELLER 'blades' can decrease the accuracy of the estimated diffusion tensors, which might result in erroneous reconstruction of white matter tracts in the brain. In this study, we investigate the effects of alterations in the b-matrix as a result of patient motion on the example of SAP-EPI DTI and eliminate these effects by incorporating our novel single-step non-linear diffusion tensor estimation scheme into the SAP-EPI post-processing procedure. Our simulations and in-vivo studies showed that, in the presence of patient motion, correcting the b-matrix is necessary in order to get more accurate diffusion tensor and white matter pathway reconstructions.
Copyright © 2010 John Wiley & Sons, Ltd.

Entities:  

Mesh:

Year:  2010        PMID: 20222149      PMCID: PMC2948637          DOI: 10.1002/nbm.1490

Source DB:  PubMed          Journal:  NMR Biomed        ISSN: 0952-3480            Impact factor:   4.044


  22 in total

1.  In vivo fiber tractography using DT-MRI data.

Authors:  P J Basser; S Pajevic; C Pierpaoli; J Duda; A Aldroubi
Journal:  Magn Reson Med       Date:  2000-10       Impact factor: 4.668

2.  Sampling and reconstruction effects due to motion in diffusion-weighted interleaved echo planar imaging.

Authors:  D Atkinson; D A Porter; D L Hill; F Calamante; A Connelly
Journal:  Magn Reson Med       Date:  2000-07       Impact factor: 4.668

3.  Multishot diffusion-weighted FSE using PROPELLER MRI.

Authors:  James G Pipe; Victoria G Farthing; Kirsten P Forbes
Journal:  Magn Reson Med       Date:  2002-01       Impact factor: 4.668

4.  Generalized autocalibrating partially parallel acquisitions (GRAPPA).

Authors:  Mark A Griswold; Peter M Jakob; Robin M Heidemann; Mathias Nittka; Vladimir Jellus; Jianmin Wang; Berthold Kiefer; Axel Haase
Journal:  Magn Reson Med       Date:  2002-06       Impact factor: 4.668

5.  Simultaneous phase correction and SENSE reconstruction for navigated multi-shot DWI with non-cartesian k-space sampling.

Authors:  Chunlei Liu; Michael E Moseley; Roland Bammer
Journal:  Magn Reson Med       Date:  2005-12       Impact factor: 4.668

6.  Clinical multishot DW-EPI through parallel imaging with considerations of susceptibility, motion, and noise.

Authors:  Stefan Skare; Rexford D Newbould; David B Clayton; Gregory W Albers; Scott Nagle; Roland Bammer
Journal:  Magn Reson Med       Date:  2007-05       Impact factor: 4.668

7.  The B-matrix must be rotated when correcting for subject motion in DTI data.

Authors:  Alexander Leemans; Derek K Jones
Journal:  Magn Reson Med       Date:  2009-06       Impact factor: 4.668

8.  Early detection of regional cerebral ischemia in cats: comparison of diffusion- and T2-weighted MRI and spectroscopy.

Authors:  M E Moseley; Y Cohen; J Mintorovitch; L Chileuitt; H Shimizu; J Kucharczyk; M F Wendland; P R Weinstein
Journal:  Magn Reson Med       Date:  1990-05       Impact factor: 4.668

9.  Origin and minimization of residual motion-related artifacts in navigator-corrected segmented diffusion-weighted EPI of the human brain.

Authors:  Hangyi Jiang; Xavier Golay; Peter C M van Zijl; Susumu Mori
Journal:  Magn Reson Med       Date:  2002-04       Impact factor: 4.668

10.  Comprehensive approach for correction of motion and distortion in diffusion-weighted MRI.

Authors:  G K Rohde; A S Barnett; P J Basser; S Marenco; C Pierpaoli
Journal:  Magn Reson Med       Date:  2004-01       Impact factor: 4.668

View more
  11 in total

1.  Reconstruction of scattered data in fetal diffusion MRI.

Authors:  Estanislao Oubel; Mériam Koob; Colin Studholme; Jean-Louis Dietemann; François Rousseau
Journal:  Med Image Anal       Date:  2011-04-27       Impact factor: 8.545

2.  Comparative study of image quality between axial T2-weighted BLADE and turbo spin-echo MRI of the upper abdomen on 3.0 T.

Authors:  Lin Zhang; ChunMei Tian; PeiYuan Wang; Liang Chen; XiJin Mao; ShanShan Wang; Xu Wang; JingMin Dong; Bin Wang
Journal:  Jpn J Radiol       Date:  2015-08-02       Impact factor: 2.374

3.  Correction of geometric distortion in Propeller echo planar imaging using a modified reversed gradient approach.

Authors:  Hing-Chiu Chang; Tzu-Chao Chuang; Yi-Ru Lin; Fu-Nien Wang; Teng-Yi Huang; Hsiao-Wen Chung
Journal:  Quant Imaging Med Surg       Date:  2013-04

Review 4.  Quantifying and modelling tissue maturation in the living human fetal brain.

Authors:  Colin Studholme; François Rousseau
Journal:  Int J Dev Neurosci       Date:  2013-07-03       Impact factor: 2.457

5.  Diffusion tensor imaging (DTI) with retrospective motion correction for large-scale pediatric imaging.

Authors:  Samantha J Holdsworth; Murat Aksoy; Rexford D Newbould; Kristen Yeom; Anh T Van; Melvyn B Ooi; Patrick D Barnes; Roland Bammer; Stefan Skare
Journal:  J Magn Reson Imaging       Date:  2012-06-11       Impact factor: 4.813

6.  High-throughput optogenetic functional magnetic resonance imaging with parallel computations.

Authors:  Zhongnan Fang; Jin Hyung Lee
Journal:  J Neurosci Methods       Date:  2013-06-04       Impact factor: 2.390

Review 7.  Diffusion tensor imaging and beyond.

Authors:  Jacques-Donald Tournier; Susumu Mori; Alexander Leemans
Journal:  Magn Reson Med       Date:  2011-04-05       Impact factor: 4.668

8.  Sex differences in associations between white matter microstructure and gonadal hormones in children and adolescents with prenatal alcohol exposure.

Authors:  K A Uban; M M Herting; J R Wozniak; E R Sowell
Journal:  Psychoneuroendocrinology       Date:  2017-05-26       Impact factor: 4.693

9.  In utero diffusion tensor imaging of the fetal brain: A reproducibility study.

Authors:  András Jakab; Ruth Tuura; Christian Kellenberger; Ianina Scheer
Journal:  Neuroimage Clin       Date:  2017-06-09       Impact factor: 4.881

10.  CSF Pulsation Artifacts on ADC Maps Obtained with Readout-segmented EPI.

Authors:  Toshio Ohashi; Shinji Naganawa; Mai Kanou; Mitsuru Ikeda
Journal:  Magn Reson Med Sci       Date:  2016-07-13       Impact factor: 2.471

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.