Literature DB >> 23867890

[Use of allergy implants in Germany: results of a survey].

M Thomsen1, M Rozak, P Thomas.   

Abstract

In a representative survey among members of the working group for joint replacement (AE) in Germany (86.7% response) it was found that 0.6% of patients with total knee arthroplasty (TKA) and 1.2% of patients with total hip arthroplasty (THA) may have a problem due to hypersensitivity to nickel or cobalt after implantation. Only one third of them may need revision surgery. Although patients with hypersensitivity are rare 84% of surgeons would prefer to use a specially coated allergy implant for knee arthroplasty patients. However, no long term results and few data on the topic of allergies and joint arthroplasty are available for these implants so that this has to be critically discussed with patients. Before a revision is performed it is recommended to perform knee arthroscopy to obtain tissue for microbiological and histopathological investigations. The second part of this questionnaire will look at the special question of how to deal with allergy patients based on constructed case examples.

Entities:  

Mesh:

Substances:

Year:  2013        PMID: 23867890     DOI: 10.1007/s00132-012-2032-6

Source DB:  PubMed          Journal:  Orthopade        ISSN: 0085-4530            Impact factor:   1.087


  24 in total

1.  [Revised consensus classification. Histopathological classification of diseases associated with joint endoprostheses].

Authors:  V Krenn; L Morawietz; H Kienapfel; R Ascherl; G Matziolis; J Hassenpflug; M Thomsen; P Thomas; M Huber; C Schuh; D Kendoff; D Baumhoer; M G Krukemeyer; G Perino; J Zustin; I Berger; W Rüther; C Poremba; T Gehrke
Journal:  Z Rheumatol       Date:  2013-05       Impact factor: 1.372

2.  Nickel (Ni) allergic patients with complications to Ni containing joint replacement show preferential IL-17 type reactivity to Ni.

Authors:  Burkhard Summer; Carina Paul; Farhad Mazoochian; Christoph Rau; Marc Thomsen; Ingo Banke; Hans Gollwitzer; Karin-Almut Dietrich; Susanne Mayer-Wagner; Thomas Ruzicka; Peter Thomas
Journal:  Contact Dermatitis       Date:  2010-07       Impact factor: 6.600

Review 3.  Metal sensitivity in patients with orthopaedic implants.

Authors:  N Hallab; K Merritt; J J Jacobs
Journal:  J Bone Joint Surg Am       Date:  2001-03       Impact factor: 5.284

4.  Metal sensitivity in patients with joint replacement arthroplasties.

Authors:  M K Benson; P G Goodwin; J Brostoff
Journal:  Br Med J       Date:  1975-11-15

Review 5.  [Alternative materials and solutions in total knee arthroplasty for patients with metal allergy].

Authors:  R Bader; P Bergschmidt; A Fritsche; S Ansorge; P Thomas; W Mittelmeier
Journal:  Orthopade       Date:  2008-02       Impact factor: 1.087

6.  [Metal sensitivity in patients with joint replacement arthroplasties before and after surgery].

Authors:  C Rau; P Thomas; M Thomsen
Journal:  Orthopade       Date:  2008-02       Impact factor: 1.087

Review 7.  [Allergy to bone cement components].

Authors:  P Thomas; A Schuh; R Eben; M Thomsen
Journal:  Orthopade       Date:  2008-02       Impact factor: 1.087

8.  [Allergy diagnostics in implant intolerance].

Authors:  P Thomas; M Thomsen
Journal:  Orthopade       Date:  2008-02       Impact factor: 1.087

9.  Comparative Study of Clinical and Radiological Outcomes of Unconstrained Bicondylar Total Knee Endoprostheses with Anti-allergic Coating.

Authors:  Philipp Bergschmidt; Rainer Bader; Susanne Finze; Christoph Schulze; Guenther Kundt; Wolfram Mittelmeier
Journal:  Open Orthop J       Date:  2011-10-07

10.  Pain in a chromium-allergic patient with total knee arthroplasty: disappearance of symptoms after revision with a special surface-coated TKA--a case report.

Authors:  Marc Thomsen; Matthias Rozak; Peter Thomas
Journal:  Acta Orthop       Date:  2011-04-20       Impact factor: 3.717

View more
  8 in total

Review 1.  [Metal implant allergy update].

Authors:  P Thomas
Journal:  Hautarzt       Date:  2016-05       Impact factor: 0.751

2.  [Total knee arthroplasty in 2014 : Results, expectations, and complications].

Authors:  G Matziolis; E Röhner
Journal:  Orthopade       Date:  2015-04       Impact factor: 1.087

Review 3.  Allergy in Total Knee Replacement. Does It Exist?: Review Article.

Authors:  Martin Faschingbauer; Lisa Renner; Friedrich Boettner
Journal:  HSS J       Date:  2016-07-22

Review 4.  [Should metal alloy discs be used for patch testing in suspected metal implant intolerance reaction?].

Authors:  P Thomas; J Geier; H Dickel; T Diepgen; U Hillen; B Kreft; A Schnuch; C Szliska; V Mahler
Journal:  Orthopade       Date:  2015-11       Impact factor: 1.087

Review 5.  [Compatibility and allergies of osteosynthesis materials].

Authors:  M Thomsen; P Thomas
Journal:  Unfallchirurg       Date:  2017-02       Impact factor: 1.000

6.  Lymphocyte transformation test reveals low prevalence of true metal hypersensitivity among pre-operative total knee arthroplasty patients.

Authors:  Tarek Boutefnouchet; Francis Vallières; Josee Delisle; Mohamed Benderdour; Julio C Fernandes
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2022-04-05       Impact factor: 4.342

7.  Allergic reactions in arthroplasty: myth or serious problem?

Authors:  Daniel Guenther; Peter Thomas; Daniel Kendoff; Mohamed Omar; Thorsten Gehrke; Carl Haasper
Journal:  Int Orthop       Date:  2015-11-02       Impact factor: 3.075

Review 8.  [Adverse reactions to metal orthopedic implants after knee arthroplasty].

Authors:  M Thomsen; V Krenn; P Thomas
Journal:  Hautarzt       Date:  2016-05       Impact factor: 0.751

  8 in total