Literature DB >> 21903909

Image quality and radiation dose of dual-energy CT of the head and neck compared with a standard 120-kVp acquisition.

A M Tawfik1, J M Kerl, A A Razek, R W Bauer, N E Nour-Eldin, T J Vogl, M G Mack.   

Abstract

BACKGROUND AND
PURPOSE: DECT offers additional image datasets with potential benefits, but its use for H&N imaging is not justified unless image quality is preserved without increased radiation dose. The aim of this work was to compare image quality and radiation dose between a DE-derived WA image dataset and a standard SECT acquisition of the H&N.
MATERIALS AND METHODS: Thirty-two patients underwent DECT of the H&N (tube voltages 80 and Sn140 kVp) and were compared with the last 32 patients who underwent standard SECT (120 kVp) on the same dual-source scanner. WA images from the 2 DE tubes were compared with images obtained with an SE mode. Radiation doses and attenuation measurements of the internal jugular vein, submandibular gland, and sternomastoid and tongue muscles were compared. Objective image noise was compared at 5 anatomic levels. Two blinded readers compared subjective image quality by using 5-point grading scales.
RESULTS: CTDI(vol) was 12% lower with DE than with SECT, a difference of 1.5 mGy, (P < .0001). Objective noise was not significantly different between DE and SECT at any of the anatomic levels (P > .05). No significant differences in attenuation measurements were observed between DE and SECT (P > .05). No significant differences in subjective image quality scores were observed between DE and SECT at any of the 5 anatomic levels (P > .05).
CONCLUSIONS: DE-derived WA images of the H&amp;N are equivalent to standard SE acquisitions and thus can be used for routine diagnostic purposes. Multiple additional image datasets can be obtained with no radiation dose penalty.

Entities:  

Mesh:

Year:  2011        PMID: 21903909      PMCID: PMC7964383          DOI: 10.3174/ajnr.A2654

Source DB:  PubMed          Journal:  AJNR Am J Neuroradiol        ISSN: 0195-6108            Impact factor:   3.825


  24 in total

Review 1.  Radiation dose in computed tomography of the heart.

Authors:  Richard L Morin; Thomas C Gerber; Cynthia H McCollough
Journal:  Circulation       Date:  2003-02-18       Impact factor: 29.690

2.  Dual-energy CT: clinical applications in various pulmonary diseases.

Authors:  Mi-Jin Kang; Chang Min Park; Chang-Hyun Lee; Jin Mo Goo; Hyun Ju Lee
Journal:  Radiographics       Date:  2010-05       Impact factor: 5.333

3.  Optimization of Z-axis automatic exposure control for multidetector row CT evaluation of neck and comparison with fixed tube current technique for image quality and radiation dose.

Authors:  S Namasivayam; M K Kalra; K M Pottala; S M Waldrop; P A Hudgins
Journal:  AJNR Am J Neuroradiol       Date:  2006 Nov-Dec       Impact factor: 3.825

Review 4.  Dual energy CT: preliminary observations and potential clinical applications in the abdomen.

Authors:  Anno Graser; Thorsten R C Johnson; Hersh Chandarana; Michael Macari
Journal:  Eur Radiol       Date:  2008-08-02       Impact factor: 5.315

5.  Characterization of urinary stones with dual-energy CT: improved differentiation using a tin filter.

Authors:  Paul Stolzmann; Sebastian Leschka; Hans Scheffel; Katharina Rentsch; Stephan Baumüller; Lotus Desbiolles; Bernhard Schmidt; Borut Marincek; Hatem Alkadhi
Journal:  Invest Radiol       Date:  2010-01       Impact factor: 6.016

6.  Dual energy versus single energy MDCT: measurement of radiation dose using adult abdominal imaging protocols.

Authors:  Lisa M Ho; Terry T Yoshizumi; Lynne M Hurwitz; Rendon C Nelson; Daniele Marin; Greta Toncheva; Sebastian T Schindera
Journal:  Acad Radiol       Date:  2009-07-10       Impact factor: 3.173

7.  Dual-energy computed tomographic pulmonary angiography: a pilot study to assess the effect on image quality and diagnostic confidence.

Authors:  Minal J Sangwaiya; Mannudeep K Kalra; Amita Sharma; Elkan F Halpern; Jo-Anne O Shepard; Subba R Digumarthy
Journal:  J Comput Assist Tomogr       Date:  2010-01       Impact factor: 1.826

8.  Dual-source dual-energy MDCT of pancreatic adenocarcinoma: initial observations with data generated at 80 kVp and at simulated weighted-average 120 kVp.

Authors:  Michael Macari; Bradley Spieler; Danny Kim; Anno Graser; Alec Jeffrey Megibow; James Babb; Hersh Chandarana
Journal:  AJR Am J Roentgenol       Date:  2010-01       Impact factor: 3.959

Review 9.  Strategies for CT radiation dose optimization.

Authors:  Mannudeep K Kalra; Michael M Maher; Thomas L Toth; Leena M Hamberg; Michael A Blake; Jo-Anne Shepard; Sanjay Saini
Journal:  Radiology       Date:  2004-01-22       Impact factor: 11.105

10.  Balancing radiation dose and image quality: clinical applications of neck volume CT.

Authors:  M T Russell; J R Fink; F Rebeles; K Kanal; M Ramos; Y Anzai
Journal:  AJNR Am J Neuroradiol       Date:  2008-01-25       Impact factor: 3.825

View more
  32 in total

1.  Dual-energy 4-phase CT scan in primary hyperparathyroidism.

Authors:  D Lau; H Yang; P L Kei
Journal:  AJNR Am J Neuroradiol       Date:  2013-06-20       Impact factor: 3.825

Review 2.  Clinical applications of dual-energy CT in head and neck imaging.

Authors:  Daniel Thomas Ginat; Michael Mayich; Laleh Daftari-Besheli; Rajiv Gupta
Journal:  Eur Arch Otorhinolaryngol       Date:  2014-12-04       Impact factor: 2.503

3.  Advanced virtual monochromatic reconstruction of dual-energy unenhanced brain computed tomography in children: comparison of image quality against standard mono-energetic images and conventional polychromatic computed tomography.

Authors:  Juil Park; Young Hun Choi; Jung-Eun Cheon; Woo Sun Kim; In-One Kim; Seong Yong Pak; Bernhard Krauss
Journal:  Pediatr Radiol       Date:  2017-06-27

4.  90-kVp low-tube-voltage CT pulmonary angiography in combination with advanced modeled iterative reconstruction algorithm: effects on radiation dose, image quality and diagnostic accuracy for the detection of pulmonary embolism.

Authors:  Doris Leithner; Tatjana Gruber-Rouh; Martin Beeres; Julian L Wichmann; Scherwin Mahmoudi; Simon S Martin; Lukas Lenga; Moritz H Albrecht; Christian Booz; Thomas J Vogl; Jan-Erik Scholtz
Journal:  Br J Radiol       Date:  2018-06-05       Impact factor: 3.039

5.  Preliminary report on virtual monochromatic spectral imaging with fast kVp switching dual energy head CT: comparable image quality to that of 120-kVp CT without increasing the radiation dose.

Authors:  Kouhei Kamiya; Akira Kunimatsu; Harushi Mori; Jiro Sato; Masaaki Akahane; Takana Yamakawa; Kuni Ohtomo
Journal:  Jpn J Radiol       Date:  2013-02-14       Impact factor: 2.374

Review 6.  Computed tomography and magnetic resonance imaging of lesions at masticator space.

Authors:  Ahmed Abdel Khalek Abdel Razek
Journal:  Jpn J Radiol       Date:  2014-02-06       Impact factor: 2.374

7.  Improvement of image quality and radiation dose of CT perfusion of the brain by means of low-tube voltage (70 KV).

Authors:  Zhen-lin Li; Hang Li; Kai Zhang; Wang-jiang Li; Xian Chen; Bin Wu; Bin Song
Journal:  Eur Radiol       Date:  2014-06-04       Impact factor: 5.315

8.  Can virtual non-enhanced CT be used to replace true non-enhanced CT for the detection of palpable cervical lymph nodes? A preliminary study.

Authors:  Yaying Yang; Xiaoxia Jia; Yamin Deng; Jiuhong Chen; Long Jiang Zhang
Journal:  Jpn J Radiol       Date:  2014-04-19       Impact factor: 2.374

9.  Dual energy CT allows for improved characterization of response to antiangiogenic treatment in patients with metastatic renal cell cancer.

Authors:  K Hellbach; A Sterzik; W Sommer; M Karpitschka; N Hummel; J Casuscelli; M Ingrisch; M Schlemmer; A Graser; Michael Staehler
Journal:  Eur Radiol       Date:  2016-09-27       Impact factor: 5.315

10.  Assessment of an Advanced Monoenergetic Reconstruction Technique in Dual-Energy Computed Tomography of Head and Neck Cancer.

Authors:  Moritz H Albrecht; Jan-Erik Scholtz; Johannes Kraft; Ralf W Bauer; Moritz Kaup; Patricia Dewes; Andreas M Bucher; Iris Burck; Jens Wagenblast; Thomas Lehnert; J Matthias Kerl; Thomas J Vogl; Julian L Wichmann
Journal:  Eur Radiol       Date:  2015-02-14       Impact factor: 5.315

View more