Literature DB >> 26987848

Reduction of peristalsis-related gastrointestinal streak artifacts with dual-energy CT: a patient and phantom study.

Sebastian Winklhofer1,2, Jack W Lambert1, Zhen Jane Wang1, Yuxin Sun1, Robert G Gould1, Ronald J Zagoria1, Benjamin M Yeh3.   

Abstract

OBJECTIVE: The purpose of the study was to assess the ability of rapid-kV switching (rs) dual-energy computed tomography (DECT) to reduce peristalsis-related streak artifact.
METHODS: rsDECT images of 100 consecutive patients (48 male, 52 female, mean age 57 years) were retrospectively evaluated in this institutional review board-approved study. Image reconstructions included virtual monochromatic 70 and 120 keV images, as well as iodine(-water) and water(-iodine) material decomposition images. We recorded the presence and severity of artifacts qualitatively (4-point scale) and quantitatively [iodine/water concentrations, Hounsfield units, gray scale values (GY)] and compared to corresponding unaffected reference tissue. Similar measures were obtained in DECT images of a peristalsis phantom. Wilcoxon signed-rank and paired t tests were used to compare results between different image reconstructions.
RESULTS: Peristalsis-related streak artifacts were found in 49 (49%) of the DECT examinations. Artifacts were significantly more severe in 70, 120, and water(-iodine) images than in iodine(-water) images (qualitative readout P < 0.001, each). Quantitative measurements were significantly different between the artifact and the reference tissue in 70, 120 keV, and water(-iodine) images (P < 0.001 for both HU and GY for each image reconstruction), but not significantly different in iodine(-water) images (iodine concentrations P = 0.088 and GY P = 0.111). Similar results were seen in the peristalsis DECT phantom study.
CONCLUSIONS: Peristalsis-related streak artifacts seen in 70, 120 keV, and water(-iodine) images are substantially reduced in iodine(-water) images at rsDECT.

Entities:  

Keywords:  Artifact reduction; Bowel peristalsis; Dual-energy computed tomography; Image quality; Iodine image

Mesh:

Year:  2016        PMID: 26987848      PMCID: PMC4974136          DOI: 10.1007/s00261-016-0702-2

Source DB:  PubMed          Journal:  Abdom Radiol (NY)


  22 in total

1.  Data consistency based rigid motion artifact reduction in fan-beam CT.

Authors:  Hengyong Yu; Ge Wang
Journal:  IEEE Trans Med Imaging       Date:  2007-02       Impact factor: 10.048

2.  Gas bubble motion artifact in MDCT.

Authors:  Franklin Liu; Carlos Cuevas; Albert A Moss; Orpheus Kolokythas; Theodore J Dubinsky; Paul E Kinahan
Journal:  AJR Am J Roentgenol       Date:  2008-02       Impact factor: 3.959

3.  Dual-energy (spectral) CT: applications in abdominal imaging.

Authors:  Alvin C Silva; Brian G Morse; Amy K Hara; Robert G Paden; Norio Hongo; William Pavlicek
Journal:  Radiographics       Date:  2011 Jul-Aug       Impact factor: 5.333

4.  CT metal artefact reduction for internal fixation of the proximal humerus: value of mono-energetic extrapolation from dual-energy and iterative reconstructions.

Authors:  S Winklhofer; E Benninger; C Spross; F Morsbach; S Rahm; S Ross; B Jost; M J Thali; P Stolzmann; H Alkadhi; R Guggenberger
Journal:  Clin Radiol       Date:  2014-02-27       Impact factor: 2.350

5.  Image fusion in dual energy computed tomography for detection of hypervascular liver hepatocellular carcinoma: phantom and preliminary studies.

Authors:  Kyung Su Kim; Jeong Min Lee; Seung Ho Kim; Kyung Won Kim; Soo Jin Kim; Seung Hyun Cho; Joon Koo Han; Byung Ihn Choi
Journal:  Invest Radiol       Date:  2010-03       Impact factor: 6.016

6.  Spectral CT with metal artifacts reduction software for improvement of tumor visibility in the vicinity of gold fiducial markers.

Authors:  Olga R Brook; Sofia Gourtsoyianni; Alexander Brook; Anand Mahadevan; Carol Wilcox; Vassilios Raptopoulos
Journal:  Radiology       Date:  2012-03-13       Impact factor: 11.105

7.  Metal artifact reduction by dual energy computed tomography using monoenergetic extrapolation.

Authors:  Fabian Bamberg; Alexander Dierks; Konstantin Nikolaou; Maximilian F Reiser; Christoph R Becker; Thorsten R C Johnson
Journal:  Eur Radiol       Date:  2011-01-20       Impact factor: 5.315

8.  Reduction of bowel motion artifact during digital subtraction angiography: a comparison of hyoscine butylbromide and glucagon.

Authors:  R I Kozak; J D Bennett; T C Brown; T Y Lee
Journal:  Can Assoc Radiol J       Date:  1994-06       Impact factor: 2.248

9.  The influence of computed tomography motion artifacts on computer-assisted surgery.

Authors:  Rüdiger Marmulla; Joachim Mühling
Journal:  J Oral Maxillofac Surg       Date:  2006-03       Impact factor: 1.895

Review 10.  Artifacts and pitfalls in MR imaging of the pelvis.

Authors:  Khashayar Rafat Zand; Caroline Reinhold; Masoom A Haider; Asako Nakai; Laurian Rohoman; Sharad Maheshwari
Journal:  J Magn Reson Imaging       Date:  2007-09       Impact factor: 4.813

View more
  4 in total

1.  Benefit of iodine density images to reduce out-of-field image artifacts at rapid kVp switching dual-energy CT.

Authors:  Brandan Dotson; Jack W Lambert; Zhen J Wang; Yuxin Sun; Michael A Ohliger; Sebastian Winklhofer; Benjamin M Yeh
Journal:  Abdom Radiol (NY)       Date:  2017-03

Review 2.  Opportunities for new CT contrast agents to maximize the diagnostic potential of emerging spectral CT technologies.

Authors:  Benjamin M Yeh; Paul F FitzGerald; Peter M Edic; Jack W Lambert; Robert E Colborn; Michael E Marino; Paul M Evans; Jeannette C Roberts; Zhen J Wang; Margaret J Wong; Peter J Bonitatibus
Journal:  Adv Drug Deliv Rev       Date:  2016-09-09       Impact factor: 15.470

3.  Dual-Energy CT Images: Pearls and Pitfalls.

Authors:  Anushri Parakh; Simon Lennartz; Chansik An; Prabhakar Rajiah; Benjamin M Yeh; Frank J Simeone; Dushyant V Sahani; Avinash R Kambadakone
Journal:  Radiographics       Date:  2021 Jan-Feb       Impact factor: 5.333

4.  Reduction of Peristalsis-Related Streak Artifacts on the Liver with Dual-Layer Spectral CT.

Authors:  Sergio Grosu; Zhen J Wang; Markus M Obmann; Mark D Sugi; Yuxin Sun; Benjamin M Yeh
Journal:  Diagnostics (Basel)       Date:  2022-03-23
  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.