Literature DB >> 20135120

Acceptance testing for nuclear medicine instrumentation.

Ellinor Busemann Sokole1, Anna Płachcínska, Alan Britten.   

Abstract

Mesh:

Year:  2010        PMID: 20135120     DOI: 10.1007/s00259-009-1348-x

Source DB:  PubMed          Journal:  Eur J Nucl Med Mol Imaging        ISSN: 1619-7070            Impact factor:   9.236


× No keyword cloud information.
  15 in total

Review 1.  Intraoperative probes.

Authors:  R K Halkar; J N Aarsvold
Journal:  J Nucl Med Technol       Date:  1999-09

2.  Introduction to PET instrumentation.

Authors:  T G Turkington
Journal:  J Nucl Med Technol       Date:  2001-03

3.  PET performance measurements using the NEMA NU 2-2001 standard.

Authors:  Margaret E Daube-Witherspoon; Joel S Karp; Michael E Casey; Frank P DiFilippo; Horace Hines; Gerd Muehllehner; Vilim Simcic; Charles W Stearns; Lars-Eric Adam; Steve Kohlmyer; Vesna Sossi
Journal:  J Nucl Med       Date:  2002-10       Impact factor: 10.057

Review 4.  Positron emission tomography versus positron emission tomography/computed tomography: from "unclear" to "new-clear" medicine.

Authors:  Gustav K von Schulthess
Journal:  Mol Imaging Biol       Date:  2004 Jul-Aug       Impact factor: 3.488

5.  An inter-laboratory comparison study of image quality of PET scanners using the NEMA NU 2-2001 procedure for assessment of image quality.

Authors:  Helmar Bergmann; Georg Dobrozemsky; Gregory Minear; Rudolf Nicoletti; Martin Samal
Journal:  Phys Med Biol       Date:  2005-04-27       Impact factor: 3.609

6.  A method to evaluate intra-operative gamma probes for sentinel lymph node localisation.

Authors:  A J Britten
Journal:  Eur J Nucl Med       Date:  1999-02

7.  Aspects of performance assessment of whole body imaging systems.

Authors:  J A Blokland; J A Camps; E K Pauwels
Journal:  Eur J Nucl Med       Date:  1997-10

8.  Measurement of collimator hole angulation and camera head tilt for slant and parallel hole collimators used in SPECT.

Authors:  E Busemann-Sokole
Journal:  J Nucl Med       Date:  1987-10       Impact factor: 10.057

Review 9.  Routine quality control of clinical nuclear medicine instrumentation: a brief review.

Authors:  Pat Zanzonico
Journal:  J Nucl Med       Date:  2008-07       Impact factor: 10.057

10.  Multiple window spatial registration error of a gamma camera: 133Ba point source as a replacement of the NEMA procedure.

Authors:  Helmar Bergmann; Maria Raith; Gregory Minear; Peter M Schaffarich
Journal:  BMC Med Phys       Date:  2008-12-09
View more
  12 in total

Review 1.  Nuclear medicine: what kind of quality would we want if we were the patient?

Authors:  Giovanni Lucignani; Angelo Del Sole
Journal:  Eur J Nucl Med Mol Imaging       Date:  2010-11       Impact factor: 9.236

2.  68Ga-PSMA PET/CT: Joint EANM and SNMMI procedure guideline for prostate cancer imaging: version 1.0.

Authors:  Wolfgang P Fendler; Matthias Eiber; Mohsen Beheshti; Jamshed Bomanji; Francesco Ceci; Steven Cho; Frederik Giesel; Uwe Haberkorn; Thomas A Hope; Klaus Kopka; Bernd J Krause; Felix M Mottaghy; Heiko Schöder; John Sunderland; Simon Wan; Hans-Jürgen Wester; Stefano Fanti; Ken Herrmann
Journal:  Eur J Nucl Med Mol Imaging       Date:  2017-06       Impact factor: 9.236

3.  EANM Dosimetry Committee series on standard operational procedures for pre-therapeutic dosimetry II. Dosimetry prior to radioiodine therapy of benign thyroid diseases.

Authors:  Heribert Hänscheid; Cristina Canzi; Wolfgang Eschner; Glenn Flux; Markus Luster; Lidia Strigari; Michael Lassmann
Journal:  Eur J Nucl Med Mol Imaging       Date:  2013-04-11       Impact factor: 9.236

Review 4.  Physical and organizational provision for installation, regulatory requirements and implementation of a simultaneous hybrid PET/MR-imaging system in an integrated research and clinical setting.

Authors:  Bernhard Sattler; Thies Jochimsen; Henryk Barthel; Kerstin Sommerfeld; Patrick Stumpp; Karl-Titus Hoffmann; Matthias Gutberlet; Arno Villringer; Thomas Kahn; Osama Sabri
Journal:  MAGMA       Date:  2012-10-09       Impact factor: 2.310

Review 5.  Practical considerations for navigating the regulatory landscape of non-clinical studies for clinical translation of radiopharmaceuticals.

Authors:  Aruna Korde; Renata Mikolajczak; Petra Kolenc; Penelope Bouziotis; Hadis Westin; Mette Lauritzen; Michel Koole; Matthias Manfred Herth; Manuel Bardiès; Andre F Martins; Antonio Paulo; Serge K Lyashchenko; Sergio Todde; Sangram Nag; Efthimis Lamprou; Antero Abrunhosa; Francesco Giammarile; Clemens Decristoforo
Journal:  EJNMMI Radiopharm Chem       Date:  2022-07-19

6.  FDG PET/CT: EANM procedure guidelines for tumour imaging: version 2.0.

Authors:  Ronald Boellaard; Roberto Delgado-Bolton; Wim J G Oyen; Francesco Giammarile; Klaus Tatsch; Wolfgang Eschner; Fred J Verzijlbergen; Sally F Barrington; Lucy C Pike; Wolfgang A Weber; Sigrid Stroobants; Dominique Delbeke; Kevin J Donohoe; Scott Holbrook; Michael M Graham; Giorgio Testanera; Otto S Hoekstra; Josee Zijlstra; Eric Visser; Corneline J Hoekstra; Jan Pruim; Antoon Willemsen; Bertjan Arends; Jörg Kotzerke; Andreas Bockisch; Thomas Beyer; Arturo Chiti; Bernd J Krause
Journal:  Eur J Nucl Med Mol Imaging       Date:  2014-12-02       Impact factor: 9.236

7.  A System-Agnostic, Adaptable and Extensible Animal Support Cradle System for Cardio-Respiratory-Synchronised, and Other, Multi-Modal Imaging of Small Animals.

Authors:  Veerle Kersemans; Stuart Gilchrist; Philip Danny Allen; Sheena Wallington; Paul Kinchesh; John Prentice; Martin Tweedie; Jamie H Warner; Sean C Smart
Journal:  Tomography       Date:  2021-02-07

8.  EANM/SNMMI practice guideline for [18F]FDG PET/CT external beam radiotherapy treatment planning in uterine cervical cancer v1.0.

Authors:  Judit A Adam; Annika Loft; Cyrus Chargari; Roberto C Delgado Bolton; Elisabeth Kidd; Heiko Schöder; Patrick Veit-Haibach; Wouter V Vogel
Journal:  Eur J Nucl Med Mol Imaging       Date:  2020-12-04       Impact factor: 9.236

9.  Accurate molecular imaging of small animals taking into account animal models, handling, anaesthesia, quality control and imaging system performance.

Authors:  Christian Vanhove; Jens P Bankstahl; Stefanie D Krämer; Eric Visser; Nicola Belcari; Stefaan Vandenberghe
Journal:  EJNMMI Phys       Date:  2015-11-11

10.  Procedural recommendations of cardiac PET/CT imaging: standardization in inflammatory-, infective-, infiltrative-, and innervation (4Is)-related cardiovascular diseases: a joint collaboration of the EACVI and the EANM.

Authors:  Riemer H J A Slart; Andor W J M Glaudemans; Olivier Gheysens; Mark Lubberink; Tanja Kero; Marc R Dweck; Gilbert Habib; Oliver Gaemperli; Antti Saraste; Alessia Gimelli; Panagiotis Georgoulias; Hein J Verberne; Jan Bucerius; Christoph Rischpler; Fabien Hyafil; Paola A Erba
Journal:  Eur J Nucl Med Mol Imaging       Date:  2020-10-27       Impact factor: 9.236

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.