PURPOSE: To compare the repeatability of the alternate cover test between experienced and inexperienced examiners and the effects of dissociation time and examiner bias.
METHODS: Two sites each had an experienced examiner train 10 subjects (inexperienced examiners) to perform short and long dissociation time alternate cover test protocols at near. Each site conducted testing sessions with an examiner triad (experienced examiner and two inexperienced examiners) who were masked to each other's results. Each triad performed the alternate cover test on 24 patients using both dissociation protocols. In an attempt to introduce bias, each of the paired inexperienced examiners was given a different graph of phoria distribution for the general population. Analysis techniques that adjust for correlations introduced when multiple measurements are obtained on the same patient were used to investigate the effect of examiner and dissociation time on each outcome.
RESULTS: The range of measured deviations spanned 27.5 prism diopters (Δ) base-in to 17.5Δ base-out. The absolute mean difference between experienced and inexperienced examiners was 2.28 ± 2.4Δ and at least 60% of differences were ≤2Δ. Larger deviations were measured with the long dissociation protocol for both experienced and inexperienced examiners (mean difference range = 1.17 to 2.14Δ, p < 0.0001). The percentage of measured small deviations (2Δ base-out to 2Δ base-in) did not differ between inexperienced examiners biased with the narrow vs. wide theoretical distributions (p = 0.41). The magnitude and direction of the deviation had no effect on the size of the differences obtained with different examiners or dissociation times.
CONCLUSIONS: Although inexperienced examiners differed significantly from experienced examiners, most differences were <2Δ suggesting good reliability of inexperienced examiners' measurements. Examiner bias did not have a substantial effect on inexperienced examiner measurements; however, increased dissociation resulted in larger measured deviations for all examiners.

Entities:  

Mesh:

Year:  2010        PMID: 20125058      PMCID: PMC3740008          DOI: 10.1097/OPX.0b013e3181d1d954

Source DB:  PubMed          Journal:  Optom Vis Sci        ISSN: 1040-5488            Impact factor:   1.973


  9 in total

1.  The effect of experience on the detection of small eye movements.

Authors:  N Fogt; B J Baughman; G Good
Journal:  Optom Vis Sci       Date:  2000-12       Impact factor: 1.973

2.  The effect of saccades and brief fusional stimuli on phoria adaptation.

Authors:  N Fogt; A J Toole
Journal:  Optom Vis Sci       Date:  2001-11       Impact factor: 1.973

3.  The intraexaminer and interexaminer repeatability of the alternate cover test using different prism neutralization endpoints.

Authors:  Heather A Johns; Ruth E Manny; Karen Fern; Ying-Sheng Hu
Journal:  Optom Vis Sci       Date:  2004-12       Impact factor: 1.973

4.  Defining real change in prism-cover test measurements.

Authors:  Jonathan M Holmes; David A Leske; George G Hohberger
Journal:  Am J Ophthalmol       Date:  2007-11-28       Impact factor: 5.258

5.  Amount of eye movement objectively perceptible to the unaided eye.

Authors:  E LUDVIGH
Journal:  Am J Ophthalmol       Date:  1949-05       Impact factor: 5.258

6.  Inter-examiner repeatability of heterophoria tests.

Authors:  B B Rainey; T L Schroeder; D A Goss; T P Grosvenor
Journal:  Optom Vis Sci       Date:  1998-10       Impact factor: 1.973

7.  Statistical methods for assessing agreement between two methods of clinical measurement.

Authors:  J M Bland; D G Altman
Journal:  Lancet       Date:  1986-02-08       Impact factor: 79.321

8.  A quantitative analysis of eye movements during the cover test--a preliminary report.

Authors:  N A Barnard; W D Thomson
Journal:  Ophthalmic Physiol Opt       Date:  1995-09       Impact factor: 3.117

9.  Interobserver reliability of the prism and alternate cover test in children with esotropia.

Authors: 
Journal:  Arch Ophthalmol       Date:  2009-01
  9 in total
  9 in total

1.  The heterophoria of 3-5 year old children as a function of viewing distance and target type.

Authors:  Mary E Troyer; Vidhyapriya Sreenivasan; T J Peper; T Rowan Candy
Journal:  Ophthalmic Physiol Opt       Date:  2016-12-05       Impact factor: 3.117

2.  Diagnostic validity of clinical signs associated with a large exophoria at near.

Authors:  Pilar Cacho-Martínez; Angel García-Muñoz; María Teresa Ruiz-Cantero
Journal:  J Ophthalmol       Date:  2013-06-17       Impact factor: 1.909

Review 3.  Traumatic brain injury and vestibulo-ocular function: current challenges and future prospects.

Authors:  Bridgett Wallace; Jonathan Lifshitz
Journal:  Eye Brain       Date:  2016-09-06

Review 4.  Convergence insufficiency: Review of clinical diagnostic signs.

Authors:  Liat Gantz; Hadas Stiebel-Kalish
Journal:  J Optom       Date:  2021-12-25

5.  The repeatability and reproducibility of four techniques for measuring horizontal heterophoria: Implications for clinical practice.

Authors:  Nicola S Anstice; Bianca Davidson; Bridget Field; Joyce Mathan; Andrew V Collins; Joanna M Black
Journal:  J Optom       Date:  2020-08-12

6.  Synchronization of a Removable Optical Element with an Eye Tracker: Test Case for Heterophoria Measurement.

Authors:  Liat Gantz; Avi Caspi
Journal:  Transl Vis Sci Technol       Date:  2020-06-29       Impact factor: 3.283

7.  An automated and objective cover test to measure heterophoria.

Authors:  Clara Mestre; Carles Otero; Fernando Díaz-Doutón; Josselin Gautier; Jaume Pujol
Journal:  PLoS One       Date:  2018-11-01       Impact factor: 3.240

8.  Measuring the heterophoria: Agreement between two methods in non-presbyopic and presbyopic patients.

Authors:  Mario Cantó-Cerdán; Pilar Cacho-Martínez; Ángel García-Muñoz
Journal:  J Optom       Date:  2017-12-01

9.  Visual Binocular Disorders and Their Relationship with Baropodometric Parameters: A Cross-Association Study.

Authors:  María Carmen Sánchez-González; Estanislao Gutiérrez-Sánchez; Pinero-Pinto Elena; Carmen Ruiz-Molinero; Verónica Pérez-Cabezas; José-Jesús Jiménez-Rejano; Manuel Rebollo-Salas
Journal:  Biomed Res Int       Date:  2020-08-04       Impact factor: 3.411

  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.