The intraexaminer and interexaminer repeatability of the alternate cover test using different prism neutralization endpoints.

Heather A Johns1, Ruth E Manny, Karen Fern, Ying-Sheng Hu.   

Abstract

PURPOSE: The alternate cover test (ACT) measures the magnitude of a deviation, but different prism endpoints may be used. This study investigated the intraexaminer and interexaminer repeatability of the ACT using two different prism neutralization endpoints.
METHODS: To determine repeatability of two prism neutralization endpoints (first neutral and midpoint of reversal), two experienced examiners measured near point phoria on 72 subjects. Measurements were repeated with examiners masked to each other and the first results. Paired t-tests were used to assess interexaminer and intraexaminer repeatability and the agreement between different prism endpoints for each examiner within each session. Signed and absolute differences in phoria magnitude were calculated.
RESULTS: For two different test sessions with the same examiner using the same prism neutralization endpoint (intraexaminer repeatability), none were significant except examiner 1 using first neutral (p = 0.038). Average signed differences (ASD's) between two test sessions for each comparison were <0.5 prism diopter (pd) with SD's of </=2.56 pd. Absolute differences ranged from 1.30 to 1.89 pd. When two different examiners used the same prism endpoint within the same session (interexaminer repeatability), there were no significant differences between examiners. ASD's between the two examiners for each comparison were </=0.53 pd with SD's </=2.03 pd. The absolute differences ranged from 1.19 to 1.67 pd. Comparisons of the two different prism endpoints by the same examiner at a single test session were all significantly different (p < 0.005), but the differences (<1 pd between the two endpoints) were not clinically significant. ASD's were <1 pd with SD <2 pd. Absolute differences ranged from 1 to 1.58 pd.
CONCLUSIONS: With experienced examiners, either prism endpoint provides high interexaminer and intraexaminer repeatability (</=0.5 pd). Although the two prism endpoints differ statistically, the differences are not clinically significant.

Entities:  

Mesh:

Year:  2004        PMID: 15592119

Source DB:  PubMed          Journal:  Optom Vis Sci        ISSN: 1040-5488            Impact factor:   1.973


  17 in total

1.  Defining real change in prism-cover test measurements.

Authors:  Jonathan M Holmes; David A Leske; George G Hohberger
Journal:  Am J Ophthalmol       Date:  2007-11-28       Impact factor: 5.258

2.  Ten-year changes in fusional vergence, phoria, and nearpoint of convergence in myopic children.

Authors:  Heather Anderson; Karla K Stuebing; Karen D Fern; Ruth E Manny
Journal:  Optom Vis Sci       Date:  2011-09       Impact factor: 1.973

3.  Effect of examiner experience and technique on the alternate cover test.

Authors:  Heather A Anderson; Ruth E Manny; Susan A Cotter; G Lynn Mitchell; Jasmine A Irani
Journal:  Optom Vis Sci       Date:  2010-03       Impact factor: 1.973

4.  Interobserver reliability of the prism and alternate cover test in children with esotropia.

Authors: 
Journal:  Arch Ophthalmol       Date:  2009-01

5.  Variability of Ocular Deviation in Strabismus.

Authors:  John R Economides; Daniel L Adams; Jonathan C Horton
Journal:  JAMA Ophthalmol       Date:  2016-01       Impact factor: 7.389

6.  Use of a Binocular Optical Coherence Tomography System to Evaluate Strabismus in Primary Position.

Authors:  Reena Chopra; Pádraig J Mulholland; Vijay K Tailor; Roger S Anderson; Pearse A Keane
Journal:  JAMA Ophthalmol       Date:  2018-07-01       Impact factor: 7.389

7.  The repeatability and reproducibility of four techniques for measuring horizontal heterophoria: Implications for clinical practice.

Authors:  Nicola S Anstice; Bianca Davidson; Bridget Field; Joyce Mathan; Andrew V Collins; Joanna M Black
Journal:  J Optom       Date:  2020-08-12

8.  Comparison, within-session repeatability and normative data of three phoria tests.

Authors:  Alessio Facchin; Silvio Maffioletti
Journal:  J Optom       Date:  2020-08-04

9.  Synchronization of a Removable Optical Element with an Eye Tracker: Test Case for Heterophoria Measurement.

Authors:  Liat Gantz; Avi Caspi
Journal:  Transl Vis Sci Technol       Date:  2020-06-29       Impact factor: 3.283

10.  An automated and objective cover test to measure heterophoria.

Authors:  Clara Mestre; Carles Otero; Fernando Díaz-Doutón; Josselin Gautier; Jaume Pujol
Journal:  PLoS One       Date:  2018-11-01       Impact factor: 3.240

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.