Literature DB >> 20118724

Dual-source computed tomographic temporal resolution provides higher image quality than 64-detector temporal resolution at low heart rates.

Philip A Araoz1, Jacobo Kirsch, Andrew N Primak, Natalie N Braun, Osama Saba, Eric E Williamson, W Scott Harmsen, Jayawant N Mandrekar, Cynthia H McCollough.   

Abstract

OBJECTIVE: To compare coronary image quality at temporal resolutions associated with dual-source computed tomography (DSCT; 83 milliseconds) and 64-detector row scanning (165 milliseconds).
METHODS: In 30 patients with a heart rate of less than 70 beats per minute, DSCT coronary angiograms were reconstructed at 83- and 165-millisecond temporal resolutions over different cardiac phases. A blinded observer graded coronary quality.
RESULTS: The typical DSCT temporal resolution (83 milliseconds) showed a significantly greater quality at end-systole for all coronary vessels and at end-diastole for the right coronary and left anterior descending coronary arteries. For all vessels, the end-diastole produced the highest quality for both temporal resolutions.
CONCLUSIONS: Imaging at 83 milliseconds creates superior quality at end-systole for all coronary vessels and at end-diastole for the right coronary and left anterior descending coronary arteries. At low heart rates, end-diastole produces the highest quality at both temporal resolutions.

Entities:  

Mesh:

Substances:

Year:  2010        PMID: 20118724      PMCID: PMC2923656          DOI: 10.1097/RCT.0b013e3181b67163

Source DB:  PubMed          Journal:  J Comput Assist Tomogr        ISSN: 0363-8715            Impact factor:   1.826


  13 in total

1.  Image quality, motion artifacts, and reconstruction timing of 64-slice coronary computed tomography angiography with 0.33-second rotation speed.

Authors:  Bernd J Wintersperger; Konstantin Nikolaou; Franz von Ziegler; Thorsten Johnson; Carsten Rist; Alexander Leber; Thomas Flohr; Andreas Knez; Maximilian F Reiser; Christoph R Becker
Journal:  Invest Radiol       Date:  2006-05       Impact factor: 6.016

2.  Optimal image reconstruction intervals for non-invasive coronary angiography with 64-slice CT.

Authors:  Sebastian Leschka; Lars Husmann; Lotus M Desbiolles; Oliver Gaemperli; Tiziano Schepis; Pascal Koepfli; Thomas Boehm; Borut Marincek; Philipp A Kaufmann; Hatem Alkadhi
Journal:  Eur Radiol       Date:  2006-05-13       Impact factor: 5.315

3.  Image quality and reconstruction intervals of dual-source CT coronary angiography: recommendations for ECG-pulsing windowing.

Authors:  Sebastian Leschka; Hans Scheffel; Lotus Desbiolles; Andre Plass; Oliver Gaemperli; Ines Valenta; Lars Husmann; Thomas G Flohr; Michele Genoni; Borut Marincek; Philipp A Kaufmann; Hatem Alkadhi
Journal:  Invest Radiol       Date:  2007-08       Impact factor: 6.016

4.  Diagnostic performance of multidetector CT angiography for assessment of coronary artery disease: meta-analysis.

Authors:  Piet K Vanhoenacker; Majanka H Heijenbrok-Kal; Ruben Van Heste; Isabel Decramer; Lieven R Van Hoe; William Wijns; M G Myriam Hunink
Journal:  Radiology       Date:  2007-08       Impact factor: 11.105

5.  Optimal electrocardiographic pulsing windows and heart rate: effect on image quality and radiation exposure at dual-source coronary CT angiography.

Authors:  Annick C Weustink; Nico R Mollet; Francesca Pugliese; Willem B Meijboom; Koen Nieman; Majanka H Heijenbrok-Kal; Thomas G Flohr; Lisanne A E Neefjes; Filippo Cademartiri; Pim J de Feyter; Gabriel P Krestin
Journal:  Radiology       Date:  2008-09       Impact factor: 11.105

6.  First performance evaluation of a dual-source CT (DSCT) system.

Authors:  Thomas G Flohr; Cynthia H McCollough; Herbert Bruder; Martin Petersilka; Klaus Gruber; Christoph Süss; Michael Grasruck; Karl Stierstorfer; Bernhard Krauss; Rainer Raupach; Andrew N Primak; Axel Küttner; Stefan Achenbach; Christoph Becker; Andreas Kopp; Bernd M Ohnesorge
Journal:  Eur Radiol       Date:  2005-12-10       Impact factor: 5.315

7.  Noninvasive coronary angiography with 64-section CT: effect of average heart rate and heart rate variability on image quality.

Authors:  Sebastian Leschka; Simon Wildermuth; Thomas Boehm; Lotus Desbiolles; Lars Husmann; André Plass; Pascal Koepfli; Tiziano Schepis; Borut Marincek; Philipp A Kaufmann; Hatem Alkadhi
Journal:  Radiology       Date:  2006-09-11       Impact factor: 11.105

8.  Optimal systolic and diastolic reconstruction windows for coronary CT angiography using dual-source CT.

Authors:  Harald Seifarth; Susanne Wienbeck; Michael Püsken; Kai-Uwe Juergens; David Maintz; Christian Vahlhaus; Walter Heindel; Roman Fischbach
Journal:  AJR Am J Roentgenol       Date:  2007-12       Impact factor: 3.959

9.  Reliable high-speed coronary computed tomography in symptomatic patients.

Authors:  Annick C Weustink; Willem B Meijboom; Nico R Mollet; Masato Otsuka; Fransesca Pugliese; Carlos van Mieghem; Roberto Malago; Niels van Pelt; Marcel L Dijkshoorn; Filippo Cademartiri; Gabriel P Krestin; Pim J de Feyter
Journal:  J Am Coll Cardiol       Date:  2007-08-06       Impact factor: 24.094

10.  Coronary artery motion and cardiac phases: dependency on heart rate -- implications for CT image reconstruction.

Authors:  Lars Husmann; Sebastian Leschka; Lotus Desbiolles; Tiziano Schepis; Oliver Gaemperli; Burkhardt Seifert; Philippe Cattin; Thomas Frauenfelder; Thomas G Flohr; Borut Marincek; Philipp A Kaufmann; Hatem Alkadhi
Journal:  Radiology       Date:  2007-09-11       Impact factor: 11.105

View more
  2 in total

1.  Radiation dose reduction in pediatric cardiac computed tomography: experience from a tertiary medical center.

Authors:  Brian B Ghoshhajra; Ashley M Lee; Leif-Christopher Engel; Csilla Celeng; Mannudeep K Kalra; Thomas J Brady; Udo Hoffmann; Sjirk J Westra; Suhny Abbara
Journal:  Pediatr Cardiol       Date:  2013-07-20       Impact factor: 1.655

Review 2.  Role of multimodality imaging in ischemic and non-ischemic cardiomyopathy.

Authors:  Karthikeyan Ananthasubramaniam; Ritesh Dhar; João L Cavalcante
Journal:  Heart Fail Rev       Date:  2011-07       Impact factor: 4.214

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.