Literature DB >> 8207452

Accuracy of beat-to-beat noninvasive measurement of finger arterial pressure using the Finapres: a spectral analysis approach.

V Novak1, P Novak, R Schondorf.   

Abstract

OBJECTIVE: Our objective was to test the accuracy of noninvasive recordings of finger arterial pressure (FAP) using the Ohmeda Finapres (Ohmeda Monitoring Systems, Englewood, CO).
METHODS: Twenty patients, aged 20 to 78 years, requiring admission to the intensive care unit and placement of intraarterial catheters participated in the study. Systolic and diastolic pressures were derived from 1-hr recordings of beat-to-beat FAP and from ipsilaterally recorded intraarterial pressure (IAP) signals. In all 20 cases, we analyzed beat-to-beat discrepancies between the actual magnitude of FAP and IAP, as well as the distribution of the consecutive differences within each of the two signals. In 10 cases, spectral analysis of the frequency content of both signals was performed.
RESULTS: The average systolic FAP (128.1 +/- 22.4 mm Hg) did not differ from IAP (127.1 +/- 19.7 mm Hg), whereas diastolic FAP (78.1 +/- 11.9 mm Hg) was greater (71.5 +/- 10.3 mm Hg) (p < 0.001). No differences in the linear trends of FAP and IAP were observed. Overall, systolic FAP and IAP were discrepant by 0.84 +/- 13.3 mm Hg (-21.82 to 25.8 mm Hg); diastolic FAP and IAP were discrepant by 6.67 +/- 5.23 mm Hg (2.68 to 13.05 mm Hg). Despite discrepancies in the magnitude of the two signals, the contour of IAP approximated that of FAP. Spectral analysis demonstrated good reproducibility and coherence between diastolic IAP and FAP fluctuations in both low-frequency (0.01 to 0.15 Hz) and high-frequency (0.15 to 0.33 Hz) bands. The low-frequency fluctuations in FAP systolic pressure were significantly amplified (p < 0.001) (gain 1.75), whereas the high-frequency fluctuations were not.
CONCLUSIONS: Over the course of 1 hr, FAP followed the contour and frequency content of IAP.

Entities:  

Mesh:

Year:  1994        PMID: 8207452     DOI: 10.1007/bf02886824

Source DB:  PubMed          Journal:  J Clin Monit        ISSN: 0748-1977


  22 in total

1.  Spectral analysis of sympathetic discharge in decerebrate cats.

Authors:  F Lombardi; N Montano; M L Finocchiaro; T G Ruscone; G Baselli; S Cerutti; A Malliani
Journal:  J Auton Nerv Syst       Date:  1990-07

2.  Continuous finger arterial pressure: utility in the cardiovascular laboratory.

Authors:  B P Imholz; W Wieling; G J Langewouters; G A van Montfrans
Journal:  Clin Auton Res       Date:  1991-03       Impact factor: 4.435

3.  Non-invasive continuous finger blood pressure measurement during orthostatic stress compared to intra-arterial pressure.

Authors:  B P Imholz; J J Settels; A H van der Meiracker; K H Wesseling; W Wieling
Journal:  Cardiovasc Res       Date:  1990-03       Impact factor: 10.787

4.  Comparison of finger and intra-arterial blood pressure monitoring at rest and during laboratory testing.

Authors:  G Parati; R Casadei; A Groppelli; M Di Rienzo; G Mancia
Journal:  Hypertension       Date:  1989-06       Impact factor: 10.190

5.  Assessment of baroreceptor reflex sensitivity by means of spectral analysis.

Authors:  H W Robbe; L J Mulder; H Rüddel; W A Langewitz; J B Veldman; G Mulder
Journal:  Hypertension       Date:  1987-11       Impact factor: 10.190

6.  Continuous non-invasive blood pressure monitoring: reliability of Finapres device during the Valsalva manoeuvre.

Authors:  B P Imholz; G A van Montfrans; J J Settels; G M van der Hoeven; J M Karemaker; W Wieling
Journal:  Cardiovasc Res       Date:  1988-06       Impact factor: 10.787

Review 7.  New investigations of autonomic nervous system function.

Authors:  R Schondorf
Journal:  J Clin Neurophysiol       Date:  1993-01       Impact factor: 2.177

8.  Time/frequency mapping of the heart rate, blood pressure and respiratory signals.

Authors:  P Novak; V Novak
Journal:  Med Biol Eng Comput       Date:  1993-03       Impact factor: 2.602

9.  Noninvasive continuous blood pressure measurement from the finger: optimal measurement conditions and factors affecting reliability.

Authors:  T Kurki; N T Smith; N Head; H Dec-Silver; A Quinn
Journal:  J Clin Monit       Date:  1987-01

Review 10.  Autonomic nervous system function.

Authors:  P A Low
Journal:  J Clin Neurophysiol       Date:  1993-01       Impact factor: 2.177

View more
  10 in total

1.  Assessment of short-term blood pressure variability in anesthetized children: a comparative study between intraarterial and finger blood pressure.

Authors:  I Constant; D Laude; J L Elghozi; I Murat
Journal:  J Clin Monit Comput       Date:  1999-05       Impact factor: 2.502

2.  BLOOD FLOW IN THE CIRCLE OF WILLIS: MODELING AND CALIBRATION.

Authors:  Kristen Devault; Pierre A Gremaud; Vera Novak; Mette S Olufsen; Guillaume Vernières; Peng Zhao
Journal:  Multiscale Model Simul       Date:  2008-01-27       Impact factor: 1.930

3.  Advanced Cross-Correlation Function Application to Identify Arterial Baroreflex Sensitivity Variations From Healthy to Diabetes Mellitus.

Authors:  Shoou-Jeng Yeh; Chi-Wen Lung; Yih-Kuen Jan; Ben-Yi Liau
Journal:  Front Neurosci       Date:  2022-06-10       Impact factor: 5.152

4.  The effect of severe brainstem injury on heart rate and blood pressure oscillations.

Authors:  V Novak; P Novak; M deMarchie; R Schondorf
Journal:  Clin Auton Res       Date:  1995-02       Impact factor: 4.435

5.  Cardiolocomotor coupling in young and elderly people.

Authors:  Vera Novak; Kun Hu; Mitul Vyas; Lewis A Lipsitz
Journal:  J Gerontol A Biol Sci Med Sci       Date:  2007-01       Impact factor: 6.053

6.  Cerebral blood flow velocity and periventricular white matter hyperintensities in type 2 diabetes.

Authors:  Vera Novak; David Last; David C Alsop; Amir M Abduljalil; Kun Hu; Lukas Lepicovsky; Jerry Cavallerano; Lewis A Lipsitz
Journal:  Diabetes Care       Date:  2006-07       Impact factor: 19.112

7.  Multimodal pressure-flow method to assess dynamics of cerebral autoregulation in stroke and hypertension.

Authors:  Vera Novak; Albert C C Yang; Lukas Lepicovsky; Ary L Goldberger; Lewis A Lipsitz; Chung-Kang Peng
Journal:  Biomed Eng Online       Date:  2004-10-25       Impact factor: 2.819

8.  Impact of cancer and chemotherapy on autonomic nervous system function and cardiovascular reactivity in young adults with cancer: a case-controlled feasibility study.

Authors:  Scott C Adams; Ronald Schondorf; Julie Benoit; Robert D Kilgour
Journal:  BMC Cancer       Date:  2015-05-18       Impact factor: 4.430

9.  Cerebral Blood Flow, Heart Rate, and Blood Pressure Patterns during the Tilt Test in Common Orthostatic Syndromes.

Authors:  Peter Novak
Journal:  Neurosci J       Date:  2016-07-20

10.  Nonlinear assessment of cerebral autoregulation from spontaneous blood pressure and cerebral blood flow fluctuations.

Authors:  Kun Hu; C K Peng; Marek Czosnyka; Peng Zhao; Vera Novak
Journal:  Cardiovasc Eng       Date:  2008-03
  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.