Literature DB >> 20028910

Patient characteristics as predictors of image quality and diagnostic accuracy of MDCT compared with conventional coronary angiography for detecting coronary artery stenoses: CORE-64 Multicenter International Trial.

Marc Dewey1, Andrea L Vavere, Armin Arbab-Zadeh, Julie M Miller, Leonardo Sara, Christopher Cox, Ilan Gottlieb, Kunihiro Yoshioka, Narinder Paul, John Hoe, Albert de Roos, Albert C Lardo, Joao A Lima, Melvin E Clouse.   

Abstract

OBJECTIVE: The purpose of the study was to investigate patient characteristics associated with image quality and their impact on the diagnostic accuracy of MDCT for the detection of coronary artery stenosis.
MATERIALS AND METHODS: Two hundred ninety-one patients with a coronary artery calcification (CAC) score of <or=600 Agatston units (214 men and 77 women; mean age, 59.3+/-10.0 years [SD]) were analyzed. An overall image quality score was derived using an ordinal scale. The accuracy of quantitative MDCT to detect significant (>or=50%) stenoses was assessed using quantitative coronary angiography (QCA) per patient and per vessel using a modified 19-segment model. The effect of CAC, obesity, heart rate, and heart rate variability on image quality and accuracy were evaluated by multiple logistic regression. Image quality and accuracy were further analyzed in subgroups of significant predictor variables. Diagnostic analysis was determined for image quality strata using receiver operating characteristic (ROC) curves.
RESULTS: Increasing body mass index (BMI) (odds ratio [OR]=0.89, p<0.001), increasing heart rate (OR=0.90, p<0.001), and the presence of breathing artifact (OR=4.97, p<or=0.001) were associated with poorer image quality whereas sex, CAC score, and heart rate variability were not. Compared with examinations of white patients, studies of black patients had significantly poorer image quality (OR=0.58, p=0.04). At a vessel level, CAC score (10 Agatston units) (OR=1.03, p=0.012) and patient age (OR=1.02, p=0.04) were significantly associated with the diagnostic accuracy of quantitative MDCT compared with QCA. A trend was observed in differences in the areas under the ROC curves across image quality strata at the vessel level (p=0.08).
CONCLUSION: Image quality is significantly associated with patient ethnicity, BMI, mean scan heart rate, and the presence of breathing artifact but not with CAC score at a patient level. At a vessel level, CAC score and age were associated with reduced diagnostic accuracy.

Entities:  

Mesh:

Year:  2010        PMID: 20028910      PMCID: PMC3294286          DOI: 10.2214/AJR.09.2833

Source DB:  PubMed          Journal:  AJR Am J Roentgenol        ISSN: 0361-803X            Impact factor:   3.959


  51 in total

1.  A reporting system on patients evaluated for coronary artery disease. Report of the Ad Hoc Committee for Grading of Coronary Artery Disease, Council on Cardiovascular Surgery, American Heart Association.

Authors:  W G Austen; J E Edwards; R L Frye; G G Gensini; V L Gott; L S Griffith; D C McGoon; M L Murphy; B B Roe
Journal:  Circulation       Date:  1975-04       Impact factor: 29.690

2.  Non-invasive coronary angiography with multislice spiral computed tomography: impact of heart rate.

Authors:  K Nieman; B J Rensing; R-J M van Geuns; J Vos; P M T Pattynama; G P Krestin; P W Serruys; P J de Feyter
Journal:  Heart       Date:  2002-11       Impact factor: 5.994

3.  Reliable noninvasive coronary angiography with fast submillimeter multislice spiral computed tomography.

Authors:  Koen Nieman; Filippo Cademartiri; Pedro A Lemos; Rolf Raaijmakers; Peter M T Pattynama; Pim J de Feyter
Journal:  Circulation       Date:  2002-10-15       Impact factor: 29.690

4.  Noninvasive visualization of coronary arteries using contrast-enhanced multidetector CT: influence of heart rate on image quality and stenosis detection.

Authors:  Tom Giesler; Ulrich Baum; Dieter Ropers; Stefan Ulzheimer; Evelyn Wenkel; Maria Mennicke; Werner Bautz; Willi A Kalender; Werner G Daniel; Stephan Achenbach
Journal:  AJR Am J Roentgenol       Date:  2002-10       Impact factor: 3.959

5.  Detection of coronary artery stenoses with thin-slice multi-detector row spiral computed tomography and multiplanar reconstruction.

Authors:  Dieter Ropers; Ulrich Baum; Karsten Pohle; Katharina Anders; Stefan Ulzheimer; Bernd Ohnesorge; Christian Schlundt; Werner Bautz; Werner G Daniel; Stephan Achenbach
Journal:  Circulation       Date:  2003-02-11       Impact factor: 29.690

6.  Multislice spiral computed tomography coronary angiography in patients with stable angina pectoris.

Authors:  Nico R Mollet; Filippo Cademartiri; Koen Nieman; Francesco Saia; Pedro A Lemos; Eugene P McFadden; Peter M T Pattynama; Patrick W Serruys; Gabriel P Krestin; Pim J de Feyter
Journal:  J Am Coll Cardiol       Date:  2004-06-16       Impact factor: 24.094

7.  Noninvasive coronary angiography by 320-row computed tomography with lower radiation exposure and maintained diagnostic accuracy: comparison of results with cardiac catheterization in a head-to-head pilot investigation.

Authors:  Marc Dewey; Elke Zimmermann; Florian Deissenrieder; Michael Laule; Hans-Peter Dübel; Peter Schlattmann; Fabian Knebel; Wolfgang Rutsch; Bernd Hamm
Journal:  Circulation       Date:  2009-08-24       Impact factor: 29.690

8.  Using the coronary artery calcium score to predict coronary heart disease events: a systematic review and meta-analysis.

Authors:  Mark J Pletcher; Jeffrey A Tice; Michael Pignone; Warren S Browner
Journal:  Arch Intern Med       Date:  2004-06-28

9.  Multisegment and halfscan reconstruction of 16-slice computed tomography for detection of coronary artery stenoses.

Authors:  Marc Dewey; Michael Laule; Lasse Krug; Dirk Schnapauff; Patrik Rogalla; Wolfgang Rutsch; Bernd Hamm; Alexander Lembcke
Journal:  Invest Radiol       Date:  2004-04       Impact factor: 6.016

10.  Influence of body size and section level on calcium phantom measurements at coronary artery calcium CT scanning.

Authors:  William Stanford; Trudy L Burns; Brad H Thompson; John D Witt; Ronald M Lauer; Larry T Mahoney
Journal:  Radiology       Date:  2004-01       Impact factor: 11.105

View more
  33 in total

1.  Sequential SPECT/CT imaging for detection of coronary artery disease in a large cohort: evaluation of the need for additional imaging and radiation exposure.

Authors:  Elsemiek M Engbers; Jorik R Timmer; Jan Paul Ottervanger; Mohamed Mouden; Ad H J Oostdijk; Siert Knollema; Pieter L Jager
Journal:  J Nucl Cardiol       Date:  2015-09-22       Impact factor: 5.952

2.  Influence of cardiac motion on stent lumen visualization in third generation dual-source CT employing a pulsatile heart model.

Authors:  Nils Petri; Tobias Gassenmaier; Thomas Allmendinger; Thomas Flohr; Wolfram Voelker; Thorsten A Bley
Journal:  Br J Radiol       Date:  2016-11-29       Impact factor: 3.039

3.  Pitfalls and bugs of nuclear and CT cardiac scans in an extremely obese patient: reasons for using conventional coronary angiography as first-line test.

Authors:  Gian Piero Carboni; Pietro Sedati; Emidio De Marco
Journal:  BMJ Case Rep       Date:  2013-05-17

4.  Diagnostic performance of combined noninvasive coronary angiography and myocardial perfusion imaging using 320-MDCT: the CT angiography and perfusion methods of the CORE320 multicenter multinational diagnostic study.

Authors:  Richard T George; Armin Arbab-Zadeh; Rodrigo J Cerci; Andrea L Vavere; Kakuya Kitagawa; Marc Dewey; Carlos E Rochitte; Andrew E Arai; Narinder Paul; Frank J Rybicki; Albert C Lardo; Melvin E Clouse; Joao A C Lima
Journal:  AJR Am J Roentgenol       Date:  2011-10       Impact factor: 3.959

5.  Radiation dose considerations by intra-individual Monte Carlo simulations in dual source spiral coronary computed tomography angiography with electrocardiogram-triggered tube current modulation and adaptive pitch.

Authors:  Matthias S May; Paul Deak; Axel Kuettner; Michael M Lell; Wolfgang Wuest; Michael Scharf; Andrea K Keller; Lothar Häberle; Stephan Achenbach; Martin Seltmann; Michael Uder; Willi A Kalender
Journal:  Eur Radiol       Date:  2011-10-09       Impact factor: 5.315

6.  Correlation between low tube voltage in dual source CT coronary artery imaging with image quality and radiation dose.

Authors:  Zi-Qiao Lei; Ping Han; Hai-Bo Xu; Jian-Ming Yu; Hong-Li Liu
Journal:  J Huazhong Univ Sci Technolog Med Sci       Date:  2014-08-19

7.  Contrast agent bolus tracking with a fixed threshold or a manual fast start for coronary CT angiography.

Authors:  Fabian Stenzel; Matthias Rief; Elke Zimmermann; Johannes Greupner; Felicitas Richter; Marc Dewey
Journal:  Eur Radiol       Date:  2014-03-26       Impact factor: 5.315

8.  Effect of Tube Voltage (100 vs. 120 kVp) on Radiation Dose and Image Quality using Prospective Gating 320 Row Multi-detector Computed Tomography Angiography.

Authors:  Atif N Khan; Faisal Khosa; Waqas Shuaib; Khurram Nasir; Ron Blankstein; Melvin Clouse
Journal:  J Clin Imaging Sci       Date:  2013-12-31

9.  Coronary artery stenoses: accuracy of 64-detector row CT angiography in segments with mild, moderate, or severe calcification--a subanalysis of the CORE-64 trial.

Authors:  Andrea L Vavere; Armin Arbab-Zadeh; Carlos E Rochitte; Marc Dewey; Hiroyuki Niinuma; Ilan Gottlieb; Melvin E Clouse; David E Bush; John W M Hoe; Albert de Roos; Christopher Cox; João A C Lima; Julie M Miller
Journal:  Radiology       Date:  2011-08-09       Impact factor: 11.105

10.  Submillisievert median radiation dose for coronary angiography with a second-generation 320-detector row CT scanner in 107 consecutive patients.

Authors:  Marcus Y Chen; Sujata M Shanbhag; Andrew E Arai
Journal:  Radiology       Date:  2013-01-22       Impact factor: 11.105

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.