A 2-D diode array and analysis software for verification of intensity modulated radiation therapy delivery.

Paul A Jursinic1, Ben E Nelms.   

Abstract

An analysis is made of a two-dimensional array of diodes that can be used for measuring dose generated in a plane by a radiation beam. This measuring device is the MapCHECK Model 1175 (Sun Nuclear, Melbourne, FL). This device has 445 N-type diodes in a 22 x 22 cm2 2-D array with variable spacing. The entire array of diodes is easily calibrated to allow for measurements in absolute dose. For IMRT quality assurance, each beam is measured individually with the beam central axis oriented perpendicular to the plane of diodes. Software is available to do the analytical comparison of measurements versus dose distributions calculated by a treatment planning system. Comparison criteria of percent difference and distance-to-agreement are defined by the operator. Data are presented that show the diode array has linear response when beam fluence changes by over 300-fold, which is typical of the level of modulation in intensity modulated radiation therapy, IMRT, beams. A linear dependence is also shown for a 100-fold change in monitors units delivered. Methods for how this device can be used in the clinic for quality assurance of IMRT fields are described. Measurements of typical IMRT beams that are modulated by compensators and MLCs are presented with comparisons to treatment planning system dose calculations. A time analysis is done for typical IMRT quality assurance measurements. The setup, calibration, and analysis time for the 2-D diode array are on the order of 20 min, depending on numbers of fields. This is significantly less time than required to do similar analysis with radiographic film. The 2-D diode array is ideal for per-plan quality assurance after an IMRT system is fully commissioned.

Mesh:

Year:  2003        PMID: 12772995     DOI: 10.1118/1.1567831

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  55 in total

1.  Dose verification of IMRT by use of a COMPASS transmission detector.

Authors:  Yuji Nakaguchi; Fujio Araki; Masato Maruyama; Shunji Saiga
Journal:  Radiol Phys Technol       Date:  2011-10-26

2.  Practical guidelines for routine intensity-modulated radiotherapy verification: pre-treatment verification with portal dosimetry and treatment verification with in vivo dosimetry.

Authors:  A J Vinall; A J Williams; V E Currie; A Van Esch; D Huyskens
Journal:  Br J Radiol       Date:  2010-11       Impact factor: 3.039

3.  Quasi-IMAT study with conventional equipment to show high plan quality with a single gantry arc.

Authors:  Judith Alvarez Moret; Oliver Kölbl; Ludwig Bogner
Journal:  Strahlenther Onkol       Date:  2009-02-18       Impact factor: 3.621

4.  The use of computed radiography plates to determine light and radiation field coincidence.

Authors:  James R Kerns; Aman Anand
Journal:  Med Phys       Date:  2013-11       Impact factor: 4.071

5.  Overestimation of low-dose radiation in intensity-modulated radiotherapy with sliding-window technique.

Authors:  Hilke Vorwerk; Daniela Wagner; Björn Seitz; Hans Christiansen; Hendrik A Wolff; Clemens F Hess
Journal:  Strahlenther Onkol       Date:  2009-12       Impact factor: 3.621

6.  Simulation for improvement of system sensitivity of radiochromic film dosimetry with different band-pass filters and scanner light intensities.

Authors:  Takeshi Kamomae; Yuki Miyabe; Akira Sawada; Osamu Matoba; Manabu Nakata; Shinsuke Yano; Toru Takakura; Takashi Mizowaki; Akio Itoh; Masahiro Hiraoka
Journal:  Radiol Phys Technol       Date:  2011-03-17

7.  Treatment planning evaluation of sliding window and multiple static segments technique in intensity modulated radiotherapy.

Authors:  Khalid Iqbal; Muhammad Isa; Saeed Ahmad Buzdar; Kent Aallen Gifford; Muhammad Afzal
Journal:  Rep Pract Oncol Radiother       Date:  2012-12-21

8.  Evaluation of a fast method of EPID-based dosimetry for intensity-modulated radiation therapy.

Authors:  Benjamin E Nelms; Karl H Rasmussen; Wolfgang A Tome
Journal:  J Appl Clin Med Phys       Date:  2010-04-19       Impact factor: 2.102

9.  Improvement of I'mRT MatriXX in terms of spatial resolution and large area acquisition for patient-specific intensity-modulated radiotherapy verification.

Authors:  Arun S Oinam; Lakhwant Singh; S C Sharma; Pradeep Goswami
Journal:  J Med Phys       Date:  2009-07

10.  Advantage of 3D volumetric dosemeter in delivery quality assurance of dynamic arc therapy: comparison of pencil beam and Monte Carlo calculations.

Authors:  H-J Shin; J H Song; J-Y Jung; Y-K Kwak; C S Kay; Y-N Kang; B O Choi; H S Jang; S H Son
Journal:  Br J Radiol       Date:  2013-11-14       Impact factor: 3.039

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.