Projection space denoising with bilateral filtering and CT noise modeling for dose reduction in CT.

Armando Manduca1, Lifeng Yu, Joshua D Trzasko, Natalia Khaylova, James M Kofler, Cynthia M McCollough, Joel G Fletcher.   

Abstract

PURPOSE: To investigate a novel locally adaptive projection space denoising algorithm for low-dose CT data.
METHODS: The denoising algorithm is based on bilateral filtering, which smooths values using a weighted average in a local neighborhood, with weights determined according to both spatial proximity and intensity similarity between the center pixel and the neighboring pixels. This filtering is locally adaptive and can preserve important edge information in the sinogram, thus maintaining high spatial resolution. A CT noise model that takes into account the bowtie filter and patient-specific automatic exposure control effects is also incorporated into the denoising process. The authors evaluated the noise-resolution properties of bilateral filtering incorporating such a CT noise model in phantom studies and preliminary patient studies with contrast-enhanced abdominal CT exams.
RESULTS: On a thin wire phantom, the noise-resolution properties were significantly improved with the denoising algorithm compared to commercial reconstruction kernels. The noise-resolution properties on low-dose (40 mA s) data after denoising approximated those of conventional reconstructions at twice the dose level. A separate contrast plate phantom showed improved depiction of low-contrast plates with the denoising algorithm over conventional reconstructions when noise levels were matched. Similar improvement in noise-resolution properties was found on CT colonography data and on five abdominal low-energy (80 kV) CT exams. In each abdominal case, a board-certified subspecialized radiologist rated the denoised 80 kV images markedly superior in image quality compared to the commercially available reconstructions, and denoising improved the image quality to the point where the 80 kV images alone were considered to be of diagnostic quality.
CONCLUSIONS: The results demonstrate that bilateral filtering incorporating a CT noise model can achieve a significantly better noise-resolution trade-off than a series of commercial reconstruction kernels. This improvement in noise-resolution properties can be used for improving image quality in CT and can be translated into substantial dose reduction.

Entities:  

Mesh:

Year:  2009        PMID: 19994500      PMCID: PMC4108640          DOI: 10.1118/1.3232004

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  18 in total

1.  Determination of the presampled MTF in computed tomography.

Authors:  J M Boone
Journal:  Med Phys       Date:  2001-03       Impact factor: 4.071

2.  Spatial domain filtering for fast modification of the tradeoff between image sharpness and pixel noise in computed tomography.

Authors:  Stefan Schaller; J E Wildberger; Rainer Raupach; Matthias Niethammer; Klaus Klingenbeck-Regn; Thomas Flohr
Journal:  IEEE Trans Med Imaging       Date:  2003-07       Impact factor: 10.048

3.  Penalized-likelihood sinogram smoothing for low-dose CT.

Authors:  Patrick J La Rivière
Journal:  Med Phys       Date:  2005-06       Impact factor: 4.071

4.  Penalized-likelihood sinogram restoration for computed tomography.

Authors:  Patrick J La Rivière; Junguo Bian; Phillip A Vargas
Journal:  IEEE Trans Med Imaging       Date:  2006-08       Impact factor: 10.048

5.  Penalized weighted least-squares approach to sinogram noise reduction and image reconstruction for low-dose X-ray computed tomography.

Authors:  Jing Wang; Tianfang Li; Hongbing Lu; Zhengrong Liang
Journal:  IEEE Trans Med Imaging       Date:  2006-10       Impact factor: 10.048

Review 6.  Computed tomography--an increasing source of radiation exposure.

Authors:  David J Brenner; Eric J Hall
Journal:  N Engl J Med       Date:  2007-11-29       Impact factor: 91.245

7.  A three-dimensional statistical approach to improved image quality for multislice helical CT.

Authors:  Jean-Baptiste Thibault; Ken D Sauer; Charles A Bouman; Jiang Hsieh
Journal:  Med Phys       Date:  2007-11       Impact factor: 4.071

8.  Patient radiation doses from adult and pediatric CT.

Authors:  Walter Huda; Awais Vance
Journal:  AJR Am J Roentgenol       Date:  2007-02       Impact factor: 3.959

9.  Dose reduction in CT by anatomically adapted tube current modulation. II. Phantom measurements.

Authors:  W A Kalender; H Wolf; C Suess
Journal:  Med Phys       Date:  1999-11       Impact factor: 4.071

10.  Dual-energy contrast-enhanced computed tomography for the detection of urinary stone disease.

Authors:  Hans Scheffel; Paul Stolzmann; Thomas Frauenfelder; Thomas Schertler; Lotus Desbiolles; Sebastian Leschka; Borut Marincek; Hatem Alkadhi
Journal:  Invest Radiol       Date:  2007-12       Impact factor: 6.016

View more
  42 in total

1.  A strategy to decrease partial scan reconstruction artifacts in myocardial perfusion CT: phantom and in vivo evaluation.

Authors:  Juan C Ramirez-Giraldo; Lifeng Yu; Birgit Kantor; Erik L Ritman; Cynthia H McCollough
Journal:  Med Phys       Date:  2012-01       Impact factor: 4.071

2.  Low-dose computed tomography image restoration using previous normal-dose scan.

Authors:  Jianhua Ma; Jing Huang; Qianjin Feng; Hua Zhang; Hongbing Lu; Zhengrong Liang; Wufan Chen
Journal:  Med Phys       Date:  2011-10       Impact factor: 4.071

3.  Achieving routine submillisievert CT scanning: report from the summit on management of radiation dose in CT.

Authors:  Cynthia H McCollough; Guang Hong Chen; Willi Kalender; Shuai Leng; Ehsan Samei; Katsuyuki Taguchi; Ge Wang; Lifeng Yu; Roderic I Pettigrew
Journal:  Radiology       Date:  2012-06-12       Impact factor: 11.105

4.  Automated detection of z-axis coverage with abdomen-pelvis computed tomography examinations.

Authors:  Min Zhang; Clinton Wellnitz; Can Cui; William Pavlicek; Teresa Wu
Journal:  J Digit Imaging       Date:  2015-06       Impact factor: 4.056

5.  Sinogram restoration in computed tomography with an edge-preserving penalty.

Authors:  Kevin J Little; Patrick J La Rivière
Journal:  Med Phys       Date:  2015-03       Impact factor: 4.071

6.  Low-dose CT via convolutional neural network.

Authors:  Hu Chen; Yi Zhang; Weihua Zhang; Peixi Liao; Ke Li; Jiliu Zhou; Ge Wang
Journal:  Biomed Opt Express       Date:  2017-01-09       Impact factor: 3.732

7.  Assessment of bilateral filter on 1/2-dose chest-pelvis CT views.

Authors:  Abdel Razzak Al-Hinnawi; Mohammed Daear; Said Huwaijah
Journal:  Radiol Phys Technol       Date:  2013-04-20

8.  SR-NLM: a sinogram restoration induced non-local means image filtering for low-dose computed tomography.

Authors:  Zhaoying Bian; Jianhua Ma; Jing Huang; Hua Zhang; Shanzhou Niu; Qianjin Feng; Zhengrong Liang; Wufan Chen
Journal:  Comput Med Imaging Graph       Date:  2013-06-24       Impact factor: 4.790

9.  Statistical iterative reconstruction using adaptive fractional order regularization.

Authors:  Yi Zhang; Yan Wang; Weihua Zhang; Feng Lin; Yifei Pu; Jiliu Zhou
Journal:  Biomed Opt Express       Date:  2016-02-24       Impact factor: 3.732

10.  Low-Dose CT With a Residual Encoder-Decoder Convolutional Neural Network.

Authors:  Hu Chen; Yi Zhang; Mannudeep K Kalra; Feng Lin; Yang Chen; Peixi Liao; Jiliu Zhou; Ge Wang
Journal:  IEEE Trans Med Imaging       Date:  2017-06-13       Impact factor: 10.048

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.