Literature DB >> 23605697

Assessment of bilateral filter on 1/2-dose chest-pelvis CT views.

Abdel Razzak Al-Hinnawi1, Mohammed Daear, Said Huwaijah.   

Abstract

A bilateral filter (BF) is a non-linear filter that has been proved to de-noise images without overrunning edges. Multi-slice computerized tomography (CT) may employ a BF to participate in dose reduction. This paper quantifies the role of the BF in achieving this objective on 1/2-dose CT. Two sets of CT images are acquired for the chest-pelvis at two different radiation doses. The BF was applied on the 1/2-dose CT images by use of various window sizes. Each time, a set of values of the BF range was fixed while the BF domain was modified. The goal was to observe the behavior of the BF on 1/2-dose CT images in comparison with full-dose CT images. The comparison was carried out by use of four co-occurrence matrix descriptors. Additionally, the peak signal-to-noise ratio (PSNR) and the mean square error (MSE) were reported. The study was applied to the sagittal, coronal, and axial CT views. The results showed that the impact of applying a BF varies among different CT views. The BF can retrieve only part of the signal being lost due to reduction of the radiation dose by one half. Yet, the BF improves the appearance of the 1/2-dose chest-pelvis CT examination. Thus, the BF can contribute to a 50% dose reduction. A procedure for employing the BF on CT machines is proposed. The results also showed that texture descriptors are similar to the PSNR and MSE in providing quantities for assessing medical image quality.

Entities:  

Mesh:

Year:  2013        PMID: 23605697     DOI: 10.1007/s12194-013-0212-7

Source DB:  PubMed          Journal:  Radiol Phys Technol        ISSN: 1865-0333


  8 in total

1.  AAPM tutorial. CT image detail and noise.

Authors:  P Sprawls
Journal:  Radiographics       Date:  1992-09       Impact factor: 5.333

2.  Radiation dose reduction in computed tomography: techniques and future perspective.

Authors:  Lifeng Yu; Xin Liu; Shuai Leng; James M Kofler; Juan C Ramirez-Giraldo; Mingliang Qu; Jodie Christner; Joel G Fletcher; Cynthia H McCollough
Journal:  Imaging Med       Date:  2009-10

Review 3.  CT dose reduction and dose management tools: overview of available options.

Authors:  Cynthia H McCollough; Michael R Bruesewitz; James M Kofler
Journal:  Radiographics       Date:  2006 Mar-Apr       Impact factor: 5.333

4.  On the origin of the bilateral filter and ways to improve it.

Authors:  Michael Elad
Journal:  IEEE Trans Image Process       Date:  2002       Impact factor: 10.856

5.  Multiresolution bilateral filtering for image denoising.

Authors:  Ming Zhang; Bahadir K Gunturk
Journal:  IEEE Trans Image Process       Date:  2008-12       Impact factor: 10.856

6.  Comparative study of two image space noise reduction methods for computed tomography: bilateral filter and nonlocal means.

Authors:  Juan C Ramirez Giraldo; Zachary S Kelm; Luis S Guimaraes; Lifeng Yu; Joel G Fletcher; Bradley J Erickson; Cynthia H McCollough
Journal:  Conf Proc IEEE Eng Med Biol Soc       Date:  2009

7.  Projection space denoising with bilateral filtering and CT noise modeling for dose reduction in CT.

Authors:  Armando Manduca; Lifeng Yu; Joshua D Trzasko; Natalia Khaylova; James M Kofler; Cynthia M McCollough; Joel G Fletcher
Journal:  Med Phys       Date:  2009-11       Impact factor: 4.071

8.  The effect of x-ray beam quality and geometry on radiation utilization efficiency in multidetector CT imaging.

Authors:  Kostas Perisinakis; Antonios E Papadakis; John Damilakis
Journal:  Med Phys       Date:  2009-04       Impact factor: 4.071

  8 in total
  3 in total

1.  Noise Reduction in CT Images Using a Selective Mean Filter.

Authors:  Anam C; Adi K; Sutanto H; Arifin Z; Budi W S; Fujibuchi T; Dougherty G
Journal:  J Biomed Phys Eng       Date:  2020-10-01

2.  Adaptively Tuned Iterative Low Dose CT Image Denoising.

Authors:  SayedMasoud Hashemi; Narinder S Paul; Soosan Beheshti; Richard S C Cobbold
Journal:  Comput Math Methods Med       Date:  2015-05-24       Impact factor: 2.238

3.  Impact of ROI Size on the Accuracy of Noise Measurement in CT on Computational and ACR Phantoms.

Authors:  Choirul Anam; Pandji Triadyaksa; Ariij Naufal; Zaenal Arifin; Zaenul Muhlisin; Evi Setiawati; Wahyu Setia Budi
Journal:  J Biomed Phys Eng       Date:  2022-08-01
  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.