Literature DB >> 19943146

Skin dose study of chest wall treatment with tomotherapy.

Khosrow Javedan1, Geoffrey Zhang, Richard Mueller, Eleanor Harris, Lawrence Berk, Kenneth Forster.   

Abstract

PURPOSE: The tangential-beam technique frequently presents challenges in homogeneity of radiation dose to the target. To ensure an adequate dose to the skin, a bolus is often used. Tomotherapy has already been shown to improve target conformity and homogeneity in other disease sites. Because of the tangential delivery technique and lack of flattening filter in TomoTherapy accelerators, we hypothesize that during chest wall irradiation using tomotherapy, the skin dose will be adequate without bolus.
MATERIALS AND METHODS: This study compares the dosimetric differences between tomotherapy chest wall irradiation and traditional linear accelerator-based tangential-beam technique. Tomotherapy treatment plans with and without bolus were compared with tangentialbeam plans. Plans were also generated for phantom studies, and point doses were measured using MOSFET dosimetry to verify the adequate skin dose. Monte Carlo simulations of static beams of both techniques were performed, and dosimetry was compared.
RESULTS: Monte Carlo simulations and measurements confirmed that beams from tomotherapy deliver a higher skin dose than a standard linear accelerator. Skin dose also increases with the incident angle of the beams.
CONCLUSION: Because of the characteristics of the tomotherapy beam and delivery technique, chest wall treatment plans from tomotherapy showed adequate skin dose [more than 75% of prescribed planning target volume (PTV) dose] even without bolus.

Mesh:

Year:  2009        PMID: 19943146     DOI: 10.1007/s11604-009-0357-9

Source DB:  PubMed          Journal:  Jpn J Radiol        ISSN: 1867-1071            Impact factor:   2.374


  20 in total

1.  Intensity-modulated tangential beam irradiation of the intact breast.

Authors:  L Hong; M Hunt; C Chui; S Spirou; K Forster; H Lee; J Yahalom; G J Kutcher; B McCormick
Journal:  Int J Radiat Oncol Biol Phys       Date:  1999-07-15       Impact factor: 7.038

2.  Measurement of radiotherapy x-ray skin dose on a chest wall phantom.

Authors:  K Y Quach; J Morales; M J Butson; A B Rosenfeld; P E Metcalfe
Journal:  Med Phys       Date:  2000-07       Impact factor: 4.071

3.  Accurate convolution/superposition for multi-resolution dose calculation using cumulative tabulated kernels.

Authors:  Weiguo Lu; Gustavo H Olivera; Ming-Li Chen; Paul J Reckwerdt; Thomas R Mackie
Journal:  Phys Med Biol       Date:  2005-02-21       Impact factor: 3.609

4.  Helical tomotherapy superficial dose measurements.

Authors:  Chester R Ramsey; Rebecca M Seibert; Benjamin Robison; Martha Mitchell
Journal:  Med Phys       Date:  2007-08       Impact factor: 4.071

5.  An assessment of the use of skin flashes in helical tomotherapy using phantom and in-vivo dosimetry.

Authors:  Koen Tournel; Dirk Verellen; Michael Duchateau; Yves Fierens; Nadine Linthout; Truus Reynders; Mia Voordeckers; Guy Storme
Journal:  Radiother Oncol       Date:  2007-06-27       Impact factor: 6.280

6.  Surface dosimetry for oblique tangential photon beams: a Monte Carlo simulation study.

Authors:  James C L Chow; Grigor N Grigorov
Journal:  Med Phys       Date:  2008-01       Impact factor: 4.071

7.  Dosimetric verification of helical tomotherapy for total scalp irradiation.

Authors:  Nicholas Hardcastle; Emilie Soisson; Peter Metcalfe; Anatoly B Rosenfeld; Wolfgang A Tome
Journal:  Med Phys       Date:  2008-11       Impact factor: 4.071

8.  A dosimetric comparison of non-coplanar IMRT versus Helical Tomotherapy for nasal cavity and paranasal sinus cancer.

Authors:  Ke Sheng; Janelle A Molloy; James M Larner; Paul W Read
Journal:  Radiother Oncol       Date:  2007-01-31       Impact factor: 6.280

9.  Dosimetric improvements following 3D planning of tangential breast irradiation.

Authors:  A Aref; D Thornton; E Youssef; T He; S Tekyi-Mensah; L Denton; G Ezzell
Journal:  Int J Radiat Oncol Biol Phys       Date:  2000-12-01       Impact factor: 7.038

10.  Quality assurance of a helical tomotherapy machine.

Authors:  J D Fenwick; W A Tomé; H A Jaradat; S K Hui; J A James; J P Balog; C N DeSouza; D B Lucas; G H Olivera; T R Mackie; B R Paliwal
Journal:  Phys Med Biol       Date:  2004-07-07       Impact factor: 3.609

View more
  4 in total

1.  Acute Toxicity From Breast Cancer Radiation Using Helical Tomotherapy With a Simultaneous Integrated Boost.

Authors:  Andrzej P Wojcieszynski; Anna K Olson; Yi Rong; Randall J Kimple; Poonam Yadav
Journal:  Technol Cancer Res Treat       Date:  2015-03-16

2.  Calculation and measurement of doses in the surface layers of a phantom when using Tomotherapy.

Authors:  Anna Kowalik; E Konstanty; Tomasz Piotrowski; Malgorzata Skórska; Julian Malicki
Journal:  Rep Pract Oncol Radiother       Date:  2019-03-01

3.  Influence of different boost techniques on radiation dose to the left anterior descending coronary artery.

Authors:  Kawngwoo Park; Yongha Lee; Jihye Cha; Sei Hwan You; Sunghyun Kim; Jong Young Lee
Journal:  Radiat Oncol J       Date:  2015-09-30

4.  Skin dose calculation during radiotherapy of head and neck cancer using deformable image registration of planning and mega-voltage computed tomography scans.

Authors:  Marco Branchini; Sara Broggi; Italo Dell'Oca; Giovanni Mauro Cattaneo; Riccardo Calandrino; Nadia Gisella Di Muzio; Claudio Fiorino
Journal:  Phys Imaging Radiat Oncol       Date:  2018-12-01
  4 in total