Literature DB >> 11121663

Dosimetric improvements following 3D planning of tangential breast irradiation.

A Aref1, D Thornton, E Youssef, T He, S Tekyi-Mensah, L Denton, G Ezzell.   

Abstract

PURPOSE: To evaluate the dosimetric difference between a simple radiation therapy plan utilizing a single contour and a more complex three-dimensional (3D) plan utilizing multiple contours, lung inhomogeneity correction, and dose-based compensators. METHODS AND MATERIALS: This is a study of the radiation therapy (RT) plans of 85 patients with early breast cancer. All patients were considered for breast-conserving management and treated by conventional tangential fields technique. Two plans were generated for each patient. The first RT plan was based on a single contour taken at the central axis and utilized two wedges. The second RT plan was generated by using the 3D planning system to design dose-based compensators after lung inhomogeneity correction had been made. The endpoints of the study were the comparison between the volumes receiving greater than 105% and greater than 110% of the reference dose, as well as the magnitude of the treated volume maximum dose. Dosimetric improvement was defined to be of significant value if the volume receiving > 105% of one plan was reduced by at least 50% with the absolute difference between the volumes being 5% or greater. The dosimetric improvements in 49 3D plans (58%) were considered of significant value. Patients' field separation and breast size did not predict the magnitude of improvement in dosimetry.
CONCLUSION: Dose-based compensator plans significantly reduced the volumes receiving > 105%, >110%, and volume maximum dose.

Entities:  

Mesh:

Year:  2000        PMID: 11121663     DOI: 10.1016/s0360-3016(00)00808-7

Source DB:  PubMed          Journal:  Int J Radiat Oncol Biol Phys        ISSN: 0360-3016            Impact factor:   7.038


  10 in total

1.  Dosimetric comparison of the field-in-field technique and tangential wedged beams for breast irradiation.

Authors:  Cem Onal; Aydan Sonmez; Gungor Arslan; Ezgi Oymak; Ayse Kotek; Esma Efe; Serhat Sonmez; Yemliha Dolek
Journal:  Jpn J Radiol       Date:  2011-12-21       Impact factor: 2.374

2.  Dosimetric comparison of field in field intensity-modulated radiotherapy technique with conformal radiotherapy techniques in breast cancer.

Authors:  Tülay Ercan; Sefik Iğdem; Gül Alço; Funda Zengin; Selin Atilla; Maktav Dinçer; Sait Okkan
Journal:  Jpn J Radiol       Date:  2010-05-29       Impact factor: 2.374

Review 3.  Radiation therapy after breast-conserving surgery.

Authors:  Naoyuki Shigematsu; Atsuya Takeda; Naoko Sanuki; Junichi Fukada; Takashi Uno; Hisao Ito; Osamu Kawaguchi; Etsuo Kunieda; Atsushi Kubo
Journal:  Radiat Med       Date:  2006-06

4.  Assessment of setup accuracy in patients receiving postmastectomy radiotherapy using electronic portal imaging.

Authors:  Funda Gul Koseoglu; Nina Tuncel; Adem Unal Kizildag; Melahat Garipagaoglu; Mustafa Adli; Cagatay Andic
Journal:  Radiat Med       Date:  2007-02-27

5.  Irregular surface compensation for radiotherapy of the breast: correlating depth of the compensation surface with breast size and resultant dose distribution.

Authors:  D J Emmens; H V James
Journal:  Br J Radiol       Date:  2009-09-14       Impact factor: 3.039

6.  Skin dose study of chest wall treatment with tomotherapy.

Authors:  Khosrow Javedan; Geoffrey Zhang; Richard Mueller; Eleanor Harris; Lawrence Berk; Kenneth Forster
Journal:  Jpn J Radiol       Date:  2009-11-27       Impact factor: 2.374

7.  Treatment planning study of Volumetric Modulated Arc Therapy and three dimensional field-in-field techniques for left chest-wall cancers with regional lymph nodes.

Authors:  Heping Xu; Gillian Hatcher
Journal:  Rep Pract Oncol Radiother       Date:  2016-08-24

8.  Semi-supervised planning method for breast electronic tissue compensation treatments based on breast radius and separation.

Authors:  Alexander R Podgorsak; Lalith K Kumaraswamy
Journal:  Radiol Oncol       Date:  2020-12-22       Impact factor: 2.991

9.  Changes in lung volume parameters regarding the received dose in the lobes of the lungs after locoregional radiotherapy of breast cancer.

Authors:  Mahsa Abdemanafi; Mohammad Bagher Tavakoli; Ali Akhavan; Iraj Abedi
Journal:  Rep Pract Oncol Radiother       Date:  2019-10-16

10.  Effects of geometrical uncertainties on whole breast radiotherapy: a comparison of four different techniques.

Authors:  Naoki Nakamura; Osamu Takahashi; Minobu Kamo; Shogo Hatanaka; Haruna Endo; Norifumi Mizuno; Naoto Shikama; Mami Ogita; Kenji Sekiguchi
Journal:  J Breast Cancer       Date:  2014-06-27       Impact factor: 3.588

  10 in total