Surface dosimetry for oblique tangential photon beams: a Monte Carlo simulation study.

James C L Chow1, Grigor N Grigorov.   

Abstract

The effect of beam obliquity on the surface relative dose profiles for the tangential photon beams was studied. The 6 and 15 MV photon beams with 4 x 4 and 10 x 10 cm2 field sizes produced by a Varian 21 EX linear accelerator were used. Phase-space models of the photon beams were created using Monte Carlo simulations based on the EGSnrc code, and were verified using film measurements. The relative dose profiles in the phantom skin, at 2 mm depth from the surface of the half-phantom geometry, or HPG, were calculated for increasing gantry angles from 270 to 280 deg clockwise. Relative dose profiles of a full phantom enclosing the whole tangential beam (full phantom geometry, or FPG) were also calculated using Monte Carlo simulation as a control for comparison. The results showed that, although the relative dose profiles in the phantom skin did not change significantly with an oblique beam using a FPG, the surface relative depth dose was increased for the HPG. In the HPG, with 6 MV photon beams and field size = 10 x 10 cm2, when the beam angle, starting from 270 deg, was increased from 1 to 3 deg, the relative depth doses in the phantom skin were increased from 68% to 79% at 10 cm depth. This increase in dose was slightly larger than the dose from 15 MV photon beams with the same field size and beam angles, where the relative depth doses in phantom skin were increased from 81% to 87% at 10 cm depth. A parameter called the percent depth dose (PDD) ratio, defined as the relative depth dose from the HPG to the relative depth dose from the FPG at a given depth along the phantom skin, was used to evaluate the effect of the phantom-air interface. It is found that the PDD ratio increased significantly when the beam angle was changed from zero to 1-3 degrees. Moreover, the PDD ratio, for a given field size, experienced a greater increase for 6 MV than for 15 MV. For the same photon beam energy, the PDD ratio increased more with a 4 x 4 cm2 field compared to 10 x 10 cm2. The results in this study will be useful for physicists and dosimetrists to predict the surface relative dose variations when using clinical tangential-like photon beams in radiation therapy.

Entities:  

Mesh:

Year:  2008        PMID: 18293563     DOI: 10.1118/1.2818956

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  5 in total

1.  Skin dose study of chest wall treatment with tomotherapy.

Authors:  Khosrow Javedan; Geoffrey Zhang; Richard Mueller; Eleanor Harris; Lawrence Berk; Kenneth Forster
Journal:  Jpn J Radiol       Date:  2009-11-27       Impact factor: 2.374

2.  A surface energy spectral study on the bone heterogeneity and beam obliquity using the flattened and unflattened photon beams.

Authors:  James C L Chow; Amir M Owrangi
Journal:  Rep Pract Oncol Radiother       Date:  2015-11-30

3.  Dosimetry of oblique tangential photon beams calculated by superposition/convolution algorithms: a Monte Carlo evaluation.

Authors:  James C L Chow; Runqing Jiang; Michael K K Leung
Journal:  J Appl Clin Med Phys       Date:  2010-11-03       Impact factor: 2.102

4.  Dosimetric characterization of whole brain radiotherapy of pediatric patients using modulated proton beams.

Authors:  Hosang Jin; Wen Hsi; Daniel Yeung; Zuofeng Li; Nancy P Mendenhall; Robert B Marcus
Journal:  J Appl Clin Med Phys       Date:  2011-01-19       Impact factor: 2.243

5.  Assessment of Fetal Dose and Health Effect to the Fetus from Breast Cancer Radiotherapy during Pregnancy.

Authors:  Pattarakan Suwanbut; Thiansin Liamsuwan; Danupon Nantajit; Wilai Masa-Nga; Chirapha Tannanonta
Journal:  Life (Basel)       Date:  2022-01-07
  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.