Literature DB >> 17079817

Accurate noninvasive measurement of infarct size in mice with high-resolution PET.

Lars Stegger1, Anne-Nadine Hoffmeier, Klaus P Schäfers, Sven Hermann, Otmar Schober, Michael A Schäfers, Gregor Theilmeier.   

Abstract

UNLABELLED: Reliable, repeatable, and time-efficient noninvasive measurement of infarct size in mice with PET would benefit studies aimed at the exploration of biochemical and functional changes associated with acute myocardial infarction (MI). PET with the radioactively labeled glucose derivative (18)F-FDG is used in humans to distinguish between viable but dysfunctional and nonviable myocardium. In this study, the feasibility, accuracy, and time efficiency of (18)F-FDG PET for quantification of infarct size in mice using a high-resolution animal PET device was evaluated in comparison with histomorphometry.
METHODS: Mice were subjected to surgery with permanent ligation of the left anterior descending artery. PET was performed before and 7 d after surgery. The infarct size was determined from the PET studies using both manual and automated delineation. The second PET scan was followed by histomorphometric analysis.
RESULTS: An excellent correlation between PET and histomorphometry was found for both manual (R = 0.98) and automated (R = 0.98) delineation, with linear regression curves close to unity (manual: y = 1.10x - 0.01; automated: y = 1.12x - 0.02). Automated analysis required <1 min per study.
CONCLUSION: The measurement of infarct size in mice with (18)F-FDG PET is feasible and highly accurate. This noninvasive methodology permits unique longitudinal studies of biochemical parameters in mice and facilitates studies that aim to assess the effect of surgical and pharmacologic intervention after acute MI.

Entities:  

Mesh:

Substances:

Year:  2006        PMID: 17079817

Source DB:  PubMed          Journal:  J Nucl Med        ISSN: 0161-5505            Impact factor:   10.057


  17 in total

Review 1.  Monitoring left ventricular function in small animals.

Authors:  Tony Lahoutte
Journal:  J Nucl Cardiol       Date:  2007 May-Jun       Impact factor: 5.952

2.  Myocardial perfusion imaging is feasible for infarct size quantification in mice using a clinical single-photon emission computed tomography system equipped with pinhole collimators.

Authors:  Tim Wollenweber; Christian Zach; Christoph Rischpler; Rebekka Fischer; Sebastian Nowak; Stephan G Nekolla; Michael Gröbner; Christopher Ubleis; Gerald Assmann; Josef Müller-Höcker; Christian La Fougére; Guido Böning; Paul Cumming; Wolfgang-Michael Franz; Marcus Hacker
Journal:  Mol Imaging Biol       Date:  2009-11-25       Impact factor: 3.488

3.  Reproducibility and accuracy of non-invasive measurement of infarct size in mice with high-resolution PET/CT.

Authors:  Adelaide Greco; Maria Piera Petretta; Michele Larobina; Sara Gargiulo; Mariarosaria Panico; Stephan G Nekolla; Giovanni Esposito; Mario Petretta; Arturo Brunetti; Alberto Cuocolo
Journal:  J Nucl Cardiol       Date:  2012-03-07       Impact factor: 5.952

4.  In-vivo monitoring of erythropoietin treatment after myocardial infarction in mice with [⁶⁸Ga]Annexin A5 and [¹⁸F]FDG PET.

Authors:  Andrei Todica; Mathias J Zacherl; Hao Wang; Guido Böning; Nathalie L Jansen; Carmen Wängler; Peter Bartenstein; Michael C Kreissl; Marcus Hacker; Stefan Brunner; Sebastian Lehner
Journal:  J Nucl Cardiol       Date:  2014-09-05       Impact factor: 5.952

5.  Noninvasive assessment of myocardial viability in a small animal model: comparison of MRI, SPECT, and PET.

Authors:  Daniel Thomas; Harshali Bal; Jeffrey Arkles; James Horowitz; Luis Araujo; Paul D Acton; Victor A Ferrari
Journal:  Magn Reson Med       Date:  2008-02       Impact factor: 4.668

6.  Telomerase expression confers cardioprotection in the adult mouse heart after acute myocardial infarction.

Authors:  Christian Bär; Bruno Bernardes de Jesus; Rosa Serrano; Agueda Tejera; Eduard Ayuso; Veronica Jimenez; Ivan Formentini; Maria Bobadilla; Jacques Mizrahi; Alba de Martino; Gonzalo Gomez; David Pisano; Francisca Mulero; Kai C Wollert; Fatima Bosch; Maria A Blasco
Journal:  Nat Commun       Date:  2014-12-18       Impact factor: 14.919

7.  Myocardial infarct size quantification in mice by SPECT using a novel algorithm independent of a normal perfusion database.

Authors:  Véronique Roelants; Marie Delgaudine; Stephan Walrand; Renaud Lhommel; Yves Beguin; François Jamar; Jean-Louis Vanoverschelde
Journal:  EJNMMI Res       Date:  2012-12-28       Impact factor: 3.138

8.  Quantification of left ventricular volumes and ejection fraction from gated 99mTc-MIBI SPECT: validation of an elastic surface model approach in comparison to cardiac magnetic resonance imaging, 4D-MSPECT and QGS.

Authors:  Lars Stegger; Claudia S A Lipke; Peter Kies; Bernd Nowak; Otmar Schober; Udalrich Buell; Michael Schäfers; Wolfgang M Schaefer
Journal:  Eur J Nucl Med Mol Imaging       Date:  2007-01-10       Impact factor: 10.057

Review 9.  PET/CT imaging in mouse models of myocardial ischemia.

Authors:  Sara Gargiulo; Adelaide Greco; Matteo Gramanzini; Maria Piera Petretta; Adele Ferro; Michele Larobina; Mariarosaria Panico; Arturo Brunetti; Alberto Cuocolo
Journal:  J Biomed Biotechnol       Date:  2012-03-13

10.  18F-FDG PET imaging-monitored anti-inflammatory therapy for acute myocardial infarction: Exploring the role of MCC950 in murine model.

Authors:  Xiang Li; Weidong Yang; Wenhui Ma; Xiang Zhou; Zhiyong Quan; Guoquan Li; Daliang Liu; Qingju Zhang; Dong Han; Beilei Gao; Congye Li; Jing Wang; Fei Kang
Journal:  J Nucl Cardiol       Date:  2020-02-03       Impact factor: 5.952

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.