Literature DB >> 19930146

Comparison of standard vs high-definition, wide-angle colonoscopy for polyp detection: a randomized controlled trial.

G Tribonias1, A Theodoropoulou, K Konstantinidis, E Vardas, K Karmiris, N Chroniaris, G Chlouverakis, G A Paspatis.   

Abstract

AIM: We sought to compare the performance of colonoscopy using a high-definition, wide-angle endoscope vs a standard colonoscope for the detection of polyps.
METHOD: A total of 390 patients were prospectively randomized into high-definition colonoscopy group (HD, n = 193) and standard colonoscopy group (SC, n = 197).
RESULTS: Analysis demonstrated that there were significant differences between the two groups, as far as the overall rate of polyps (SC, 1.31 ± 1.90; HD, 1.76 ± 2.31; P = 0.03) and the rate of small hyperplastic polyps (size < 5 mm; SC, 0.10 ± 0.36; HD, 0.25 ± 0.61; P = 0.003) were concerned. No significant differences between the two groups were observed, regarding large polyps (size ≥ 10 mm; SC, 0.39 ± 0.89; HD, 0.48 ± 0.80; P = 0.10), medium polyps (10 mm > size ≥ 5 mm; SC, 0.60 ± 1.46; HD, 0.58 ± 1.25; P = 0.31) and small polyps (size < 5 mm; SC, 0.32 ± 0.86; HD, 0.71 ± 1.65; P = 0.09). Similarly, no significant differences were demonstrated in the detection rate of adenomas and hyperplastic polyps, large adenomas, medium adenomas, small adenomas and large and medium hyperplastic polyps.
CONCLUSION: High-definition colonoscopy led to a significant increase in the polyp detection.
© 2010 The Authors. Colorectal Disease © 2010 The Association of Coloproctology of Great Britain and Ireland.

Entities:  

Mesh:

Year:  2010        PMID: 19930146     DOI: 10.1111/j.1463-1318.2009.02145.x

Source DB:  PubMed          Journal:  Colorectal Dis        ISSN: 1462-8910            Impact factor:   3.788


  22 in total

1.  Short turn radius colonoscope in an anatomical model: retroflexed withdrawal and detection of hidden polyps.

Authors:  Sarah K McGill; Shivangi Kothari; Shai Friedland; Ann Chen; Walter G Park; Subhas Banerjee
Journal:  World J Gastroenterol       Date:  2015-01-14       Impact factor: 5.742

Review 2.  Can Technology Improve the Quality of Colonoscopy?

Authors:  Selvi Thirumurthi; William A Ross; Gottumukkala S Raju
Journal:  Curr Gastroenterol Rep       Date:  2016-07

Review 3.  Endoscopic innovations to increase the adenoma detection rate during colonoscopy.

Authors:  Vincent K Dik; Leon Mg Moons; Peter D Siersema
Journal:  World J Gastroenterol       Date:  2014-03-07       Impact factor: 5.742

4.  The use of high definition colonoscopy versus standard definition: does it affect polyp detection rate?

Authors:  John Richardson; Anthony Thaventhiran; Hugh Mackenzie; Benjamin Stubbs
Journal:  Surg Endosc       Date:  2017-11-03       Impact factor: 4.584

5.  Role of high definition colonoscopy in colorectal adenomatous polyp detection.

Authors:  Tolga Erim; John M Rivas; Evelio Velis; Fernando Castro
Journal:  World J Gastroenterol       Date:  2011-09-21       Impact factor: 5.742

Review 6.  New aspects of modern endoscopy.

Authors:  Johannes Wilhelm Rey; Ralf Kiesslich; Arthur Hoffman
Journal:  World J Gastrointest Endosc       Date:  2014-08-16

7.  High-definition colonoscopy with i-Scan: better diagnosis for small polyps and flat adenomas.

Authors:  Pier Alberto Testoni; Chiara Notaristefano; Cristian Vailati; Milena Di Leo; Edi Viale
Journal:  World J Gastroenterol       Date:  2012-10-07       Impact factor: 5.742

Review 8.  Endoscopic mucosal imaging of gastrointestinal neoplasia in 2013.

Authors:  P Urquhart; R DaCosta; N Marcon
Journal:  Curr Gastroenterol Rep       Date:  2013-07

9.  Feasibility of full-spectrum endoscopy: Korea's first full-spectrum endoscopy colonoscopic trial.

Authors:  Jeong-Yeop Song; Youn Hee Cho; Mi A Kim; Jeong-Ae Kim; Chun Tek Lee; Moon Sung Lee
Journal:  World J Gastroenterol       Date:  2016-02-28       Impact factor: 5.742

10.  Endoscopists with low adenoma detection rates benefit from high-definition endoscopy.

Authors:  Elisabeth Waldmann; Martha Britto-Arias; Irina Gessl; Georg Heinze; Petra Salzl; Daniela Sallinger; Michael Trauner; Werner Weiss; Arnulf Ferlitsch; Monika Ferlitsch
Journal:  Surg Endosc       Date:  2014-07-09       Impact factor: 4.584

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.