Literature DB >> 26937150

Feasibility of full-spectrum endoscopy: Korea's first full-spectrum endoscopy colonoscopic trial.

Jeong-Yeop Song1, Youn Hee Cho1, Mi A Kim1, Jeong-Ae Kim1, Chun Tek Lee1, Moon Sung Lee1.   

Abstract

AIM: To evaluate the full-spectrum endoscopy (FUSE) colonoscopy system as the first report on the utility thereof in a Korean population.
METHODS: We explored the efficacy of the FUSE colonoscopy in a retrospective, single-center feasibility study performed between February 1 and July 20, 2015. A total of 262 subjects (age range: 22-80) underwent the FUSE colonoscopy for colorectal cancer screening, polyp surveillance, or diagnostic evaluation. The cecal intubation success rate, the polyp detection rate (PDR), the adenoma detection rate (ADR), and the diverticulum detection rate (DDR), were calculated. Also, the success rates of therapeutic interventions were evaluated with biopsy confirmation.
RESULTS: All patients completed the study and the success rates of cecal and terminal ileal intubation were 100% with the FUSE colonoscope; we found 313 polyps in 142 patients and 173 adenomas in 95. The overall PDR, ADR and DDR were 54.2%, 36.3%, and 25.2%, respectively, and were higher in males, and increased with age. The endoscopists and nurses involved considered that the full-spectrum colonoscope improved navigation and orientation within the colon. No colonoscopy was aborted because of colonoscope malfunction.
CONCLUSION: The FUSE colonoscopy yielded a higher PDR, ADR, DDR than did traditional colonoscopy, without therapeutic failure or complications, showing feasible, effective, and safe in this first Korean trial.

Entities:  

Keywords:  Colonic polyps; Colonoscopes; Colonoscopy; Feasibility studies

Mesh:

Year:  2016        PMID: 26937150      PMCID: PMC4768208          DOI: 10.3748/wjg.v22.i8.2621

Source DB:  PubMed          Journal:  World J Gastroenterol        ISSN: 1007-9327            Impact factor:   5.742


  42 in total

1.  Surface visualization at CT colonography simulated colonoscopy: effect of varying field of view and retrograde view.

Authors:  James E East; Brian P Saunders; David Burling; Darren Boone; Steve Halligan; Stuart A Taylor
Journal:  Am J Gastroenterol       Date:  2007-07-19       Impact factor: 10.864

2.  Chromoendoscopy with indigocarmine improves the detection of adenomatous and nonadenomatous lesions in the colon.

Authors:  R Kiesslich; M von Bergh; M Hahn; G Hermann; M Jung
Journal:  Endoscopy       Date:  2001-12       Impact factor: 10.093

3.  Impact of experience with a retrograde-viewing device on adenoma detection rates and withdrawal times during colonoscopy: the Third Eye Retroscope study group.

Authors:  Daniel C DeMarco; Elizabeth Odstrcil; Luis F Lara; David Bass; Chase Herdman; Timothy Kinney; Kapil Gupta; Leon Wolf; Thomas Dewar; Thomas M Deas; Manoj K Mehta; M Badar Anwer; Randall Pellish; J Kent Hamilton; Daniel Polter; K Gautham Reddy; Ira Hanan
Journal:  Gastrointest Endosc       Date:  2010-03       Impact factor: 9.427

4.  Endocuff-assisted colonoscopy increases polyp detection rate: a simulated randomized study involving an anatomic colorectal model and 32 international endoscopists.

Authors:  Mathieu Pioche; Minori Matsumoto; Hiroyuki Takamaru; Taku Sakamoto; Takeshi Nakajima; Takahisa Matsuda; Seiichiro Abe; Yasuo Kakugawa; Yosuke Otake; Yutaka Saito
Journal:  Surg Endosc       Date:  2015-04-11       Impact factor: 4.584

5.  Quality indicators for colonoscopy and the risk of interval cancer.

Authors:  Michal F Kaminski; Jaroslaw Regula; Ewa Kraszewska; Marcin Polkowski; Urszula Wojciechowska; Joanna Didkowska; Maria Zwierko; Maciej Rupinski; Marek P Nowacki; Eugeniusz Butruk
Journal:  N Engl J Med       Date:  2010-05-13       Impact factor: 91.245

6.  A randomized controlled trial evaluating the usefulness of a transparent hood attached to the tip of the colonoscope.

Authors:  Shintaro Kondo; Yutaka Yamaji; Hirotsugu Watabe; Atsuo Yamada; Takafumi Sugimoto; Miki Ohta; Keiji Ogura; Makoto Okamoto; Haruhiko Yoshida; Takao Kawabe; Masao Omata
Journal:  Am J Gastroenterol       Date:  2006-11-13       Impact factor: 10.864

7.  Colonoscopic withdrawal times and adenoma detection during screening colonoscopy.

Authors:  Robert L Barclay; Joseph J Vicari; Andrea S Doughty; John F Johanson; Roger L Greenlaw
Journal:  N Engl J Med       Date:  2006-12-14       Impact factor: 91.245

8.  Miss rate for colorectal neoplastic polyps: a prospective multicenter study of back-to-back video colonoscopies.

Authors:  D Heresbach; T Barrioz; M G Lapalus; D Coumaros; P Bauret; P Potier; D Sautereau; C Boustière; J C Grimaud; C Barthélémy; J Sée; I Serraj; P N D'Halluin; B Branger; T Ponchon
Journal:  Endoscopy       Date:  2008-04       Impact factor: 10.093

9.  Impact of proximal colon retroflexion on adenoma miss rates.

Authors:  Matthew Harrison; Navjot Singh; Douglas K Rex
Journal:  Am J Gastroenterol       Date:  2004-03       Impact factor: 10.864

10.  Impact of wide-angle, high-definition endoscopy in the diagnosis of colorectal neoplasia: a randomized controlled trial.

Authors:  Maria Pellisé; Glòria Fernández-Esparrach; Andrés Cárdenas; Oriol Sendino; Elena Ricart; Eva Vaquero; Antonio Z Gimeno-García; Cristina Rodríguez de Miguel; Michel Zabalza; Angels Ginès; Josep M Piqué; Josep Llach; Antoni Castells
Journal:  Gastroenterology       Date:  2008-07-09       Impact factor: 22.682

View more
  5 in total

1.  Proximal retroflexion versus second forward view of the right colon during screening colonoscopy: A multicentre randomized controlled trial.

Authors:  Ma Henar Núñez Rodríguez; Pilar Díez Redondo; Fausto Riu Pons; Marta Cimavilla; Luis Hernández; Andrea Loza; Manuel Pérez-Miranda
Journal:  United European Gastroenterol J       Date:  2020-05-07       Impact factor: 4.623

2.  Impact of Full Spectrum Endoscopy® (Fuse®, EndoChoice®) on adenoma detection: a prospective French pilot study.

Authors:  Jean-Philippe Ratone; Erwan Bories; Fabrice Caillol; Christian Pesenti; Sébastien Godat; Floriane Sellier; Solene Hoibian; Marine Landon; Cécilia Servajean; Chiara De Cassan; Valentin Lestelle; Jean-Patrick Casanova; Flora Poizat; Marc Giovannini
Journal:  Ann Gastroenterol       Date:  2017-07-05

Review 3.  New endoscopes and add-on devices to improve colonoscopy performance.

Authors:  Paraskevas Gkolfakis; Georgios Tziatzios; George D Dimitriadis; Konstantinos Triantafyllou
Journal:  World J Gastroenterol       Date:  2017-06-07       Impact factor: 5.742

4.  Panoramic colonoscopy in colorectal cancer screening - a randomized controlled trial.

Authors:  Paweł Bogacki; Tomasz Gach; Jan Krzak; Miroslaw Szura
Journal:  Wideochir Inne Tech Maloinwazyjne       Date:  2021-02-25       Impact factor: 1.195

Review 5.  Can technology increase adenoma detection rate?

Authors:  Wee Sing Ngu; Colin Rees
Journal:  Therap Adv Gastroenterol       Date:  2018-01-10       Impact factor: 4.409

  5 in total