Literature DB >> 1991354

Virtual cathode effects during stimulation of cardiac muscle. Two-dimensional in vivo experiments.

J P Wikswo1, T A Wisialowski, W A Altemeier, J R Balser, H A Kopelman, D M Roden.   

Abstract

We have found that when suprathreshold cathodal stimuli were applied to the epicardium of canine ventricle, impulse propagation originated at a "virtual cathode" with dimensions greater than those of the physical cathode. We report the two-dimensional geometry of the virtual cathode as a function of stimulus strength; the results are compared with the predictions of an anisotropic, bidomain model of cardiac conduction recently developed in our laboratories. Data were collected in six pentobarbital-anesthetized dogs by using a small plaque electrode sewn to the left ventricular epicardium. Arrival times at closely spaced bipolar electrodes oriented radially around a central cathode were obtained as a function of stimulus strength and fiber orientation. The dimensions of the virtual cathode were determined by linear back-extrapolation of arrival times to the time of stimulation. The directional dependence of the conduction velocity was consistent with previous reports: at 1 mA, longitudinal (0 degree) and transverse (90 degrees) velocities were 0.60 +/- 0.03 and 0.29 +/- 0.02 m/sec, respectively. At 7 mA, the longitudinal velocity was 0.75 +/- 0.05 m/sec, whereas there was no significant change in the transverse velocity. In contrast to conduction velocity, the virtual cathode was smallest in the longitudinal orientation and largest between 45 degrees and 60 degrees. Virtual cathode size was dependent on both orientation and stimulus strength: at 0 degree, the virtual cathode was small (approximately 1 mm) and relatively constant over the range of 1-7 mA; at oblique orientations (45 degrees-90 degrees), it displayed a roughly logarithmic dependence on stimulus strength, approximately 1 mm at 1 mA and approximately 3 mm at 7 mA. The bidomain, anisotropic model reproduced both the stimulus strength and the fiber-orientation dependence of the virtual cathode geometry when the intracellular and extracellular anisotropies were 10:1 and 4:1, respectively, but not when the two anisotropies were equal. We suggest that the virtual cathode provides a direct measure of the determinants of cardiac activation; its complex geometry appears to reflect the bidomain, anisotropic nature of cardiac muscle.

Entities:  

Mesh:

Year:  1991        PMID: 1991354     DOI: 10.1161/01.res.68.2.513

Source DB:  PubMed          Journal:  Circ Res        ISSN: 0009-7330            Impact factor:   17.367


  23 in total

1.  Analysis of electric field stimulation of single cardiac muscle cells.

Authors:  L Tung; J R Borderies
Journal:  Biophys J       Date:  1992-08       Impact factor: 4.033

2.  Probing field-induced tissue polarization using transillumination fluorescent imaging.

Authors:  Bryan J Caldwell; Marcel Wellner; Bogdan G Mitrea; Arkady M Pertsov; Christian W Zemlin
Journal:  Biophys J       Date:  2010-10-06       Impact factor: 4.033

3.  Pace mapping in the atrium using bipolar electrograms from widely spaced electrodes.

Authors:  Raja J Selvaraj; Sreekanth Yerram; Pradeep Kumar; Santhosh Satheesh; Ajith Ananthakrishna Pillai; Mahesh Kumar Saktheeswaran; Jayaraman Balachander
Journal:  J Arrhythm       Date:  2015-03-20

4.  Electrophysiological interaction through the interstitial space between adjacent unmyelinated parallel fibers.

Authors:  R C Barr; R Plonsey
Journal:  Biophys J       Date:  1992-05       Impact factor: 4.033

5.  Polarity reversal lowers activation time during diastolic field stimulation of the rabbit ventricles: insights into mechanisms.

Authors:  M M Maleckar; M C Woods; V Y Sidorov; M R Holcomb; D N Mashburn; J P Wikswo; N A Trayanova
Journal:  Am J Physiol Heart Circ Physiol       Date:  2008-08-15       Impact factor: 4.733

6.  Virtual electrodes and the induction of fibrillation in Langendorff-perfused rabbit ventricles: the role of intracellular calcium.

Authors:  Hideki Hayashi; Shien-Fong Lin; Boyoung Joung; Hrayr S Karagueuzian; James N Weiss; Peng-Sheng Chen
Journal:  Am J Physiol Heart Circ Physiol       Date:  2008-08-01       Impact factor: 4.733

7.  Diastolic field stimulation: the role of shock duration in epicardial activation and propagation.

Authors:  Marcella C Woods; Ilija Uzelac; Mark R Holcomb; John P Wikswo; Veniamin Y Sidorov
Journal:  Biophys J       Date:  2013-07-16       Impact factor: 4.033

8.  Control of action potential duration alternans in canine cardiac ventricular tissue.

Authors:  Uche B Kanu; Shahriar Iravanian; Robert F Gilmour; David J Christini
Journal:  IEEE Trans Biomed Eng       Date:  2010-10-28       Impact factor: 4.538

9.  Impact of changing activation sequence on bipolar electrogram amplitude for voltage mapping of left ventricular infarcts causing ventricular tachycardia.

Authors:  Corinna B Brunckhorst; Etienne Delacretaz; Kyoko Soejima; William H Maisel; Peter L Friedman; William G Stevenson
Journal:  J Interv Card Electrophysiol       Date:  2005-03       Impact factor: 1.900

10.  Myocardial electrical propagation in patients with idiopathic dilated cardiomyopathy.

Authors:  K P Anderson; R Walker; P Urie; P R Ershler; R L Lux; S V Karwandee
Journal:  J Clin Invest       Date:  1993-07       Impact factor: 14.808

View more